Coronary artery disease (CAD) is the leading cause of death in the United States, even though significant efforts have been made in prevention and diagnosis. The clinical gold standard for diagnosis of CAD is catheter-based invasive x-ray angiography, performed more than a million times per year. Of these examinations, up to 35% have been found to have no significant stenosis, yet these patients had to go through the potential risks and complications of an invasive test that further exposes the patient to ionizing radiation and iodinated contrast. Thus, non-invasive diagnostic alternatives are highly desirable. Cardiac MRI (CMR) provides a method for comprehensive non-invasive cardiac exam, including contractile functional assessment (cine CMR) to detect wall-motion abnormality, myocardial CMR perfusion for diagnosing perfusion defects, viability assessment using late gadolinium enhancement (LGE) for evaluation of acute and chronic myocardial infarction, and coronary MRI for the identification of stenosis. CMR is advantageous in several respects, since it does not require ionizing radiation or iodinated contrast, thereby facilitating repeated or follow-up scanning. However, long data acquisition time remains as one of its main limitations. Several approaches have been studied to facilitate rapid CMR acquisition. Nonetheless, the acquisition time for high-resolution CMR remains long, and spatial and temporal resolution is traded off for acquisition time in cine and perfusion imaging. Therefore, developments of methods to reduce data acquisition time beyond what is available now are appealing. We will develop novel reconstruction methodologies for high-resolution CMR that learn the anatomical structures in the images being reconstructed. We will validate these techniques in a range of contrast-enhanced CMR imaging protocols, providing better volumetric coverage of the heart, efficient use of the contrast agents, and higher spatial and temporal resolution.

Public Health Relevance

Coronary artery disease (CAD) is the leading cause of death in the United States. Cardiac MRI provides a technique for a non-invasive non-ionizing cardiac exam, which can be used in the diagnosis of CAD. In this work, we develop and validate techniques for acceleration of cardiac MRI, offering better volumetric coverage of the heart, improved contrast, and spatial and temporal resolution.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Transition Award (R00)
Project #
5R00HL111410-05
Application #
9327795
Study Section
Special Emphasis Panel (NSS)
Program Officer
Evans, Frank
Project Start
2012-06-01
Project End
2019-08-31
Budget Start
2017-09-01
Budget End
2019-08-31
Support Year
5
Fiscal Year
2017
Total Cost
Indirect Cost
Name
University of Minnesota Twin Cities
Department
Engineering (All Types)
Type
Biomed Engr/Col Engr/Engr Sta
DUNS #
555917996
City
Minneapolis
State
MN
Country
United States
Zip Code
55455
Lin, Lucy Q; Kazmirczak, Felipe; Chen, Ko-Hsuan Amy et al. (2018) Impact of Cardiovascular Magnetic Resonance Imaging on Identifying the Etiology of Cardiomyopathy in Patients Undergoing Cardiac Transplantation. Sci Rep 8:16212
Weingärtner, Sebastian; Shenoy, Chetan; Rieger, Benedikt et al. (2018) Temporally resolved parametric assessment of Z-magnetization recovery (TOPAZ): Dynamic myocardial T1 mapping using a cine steady-state look-locker approach. Magn Reson Med 79:2087-2100
Rieger, Benedikt; Akçakaya, Mehmet; Pariente, José C et al. (2018) Time efficient whole-brain coverage with MR Fingerprinting using slice-interleaved echo-planar-imaging. Sci Rep 8:6667
Moeller, Steen; Weingartner, Sebastian; Akcakaya, Mehmet (2017) Multi-scale locally low-rank noise reduction for high-resolution dynamic quantitative cardiac MRI. Conf Proc IEEE Eng Med Biol Soc 2017:1473-1476
Basha, Tamer A; Akçakaya, Mehmet; Liew, Charlene et al. (2017) Clinical performance of high-resolution late gadolinium enhancement imaging with compressed sensing. J Magn Reson Imaging 46:1829-1838
Weingärtner, Sebastian; Meßner, Nadja M; Zöllner, Frank G et al. (2017) Black-blood native T1 mapping: Blood signal suppression for reduced partial voluming in the myocardium. Magn Reson Med 78:484-493
Weingärtner, Sebastian; Zimmer, Fabian; Metzger, Gregory J et al. (2017) Motion-robust cardiac B1+ mapping at 3T using interleaved bloch-siegert shifts. Magn Reson Med 78:670-677
Weingärtner, Sebastian; Moeller, Steen; Schmitter, Sebastian et al. (2017) Simultaneous multislice imaging for native myocardial T1 mapping: Improved spatial coverage in a single breath-hold. Magn Reson Med 78:462-471
Akçakaya, Mehmet; Weingärtner, Sebastian; Basha, Tamer A et al. (2016) Joint myocardial T1 and T2 mapping using a combination of saturation recovery and T2 -preparation. Magn Reson Med 76:888-96
Akçakaya, Mehmet; Weingärtner, Sebastian; Roujol, Sébastien et al. (2015) On the selection of sampling points for myocardial T1 mapping. Magn Reson Med 73:1741-53