Functional engineering of load-bearing tissues is challenging because the tissue engineered construct (TEC) must withstand the rigorous loads associated with the in vivo environments. Determining mechanical design parameters for TECs requires that mechanical' behavior and structure-function relationships of both native tissue and the TEC be given emphasis. Our goals are to quantify tissue structure-function relationships and identify the parameters most significant for the successful design of a TEC. We hypothesize that collagen fiber architecture is a critical variable for tissue mechanical function. Our preliminary work supports this contention and has led to early mathematical models providing insight into these relationships. Additionally, our preliminary work suggests that magnetic resonance imaging to non-invasively assess fiber architecture may provide input to our mathematical models to predict in vivo mechanics. Therefore, we propose a design paradigm that integrates sophisticated and rigorous mechanical testing, non-invasive tissue architectural measurements, and mathematical models of structure-function relationships, which, when combined with other biotechnologies, will advance the design of load-bearing TECs and lead to their successful use in clinical repair and replacement applications.
Aim 1. Measure mechanics, fiber architecture, and composition of native tissue.
Aim 2. Quantify structure-function relationships of native tissue using a mathematical model.
Aim 3. Quantify structure-function relationships of a tissue engineered construct. We hypothesize a functional relationship exists between collagen architecture and mechanical behavior in the intervertebral disc. We further hypothesize that, like native tissue, the mechanical behavior of a load-bearing TEC can be predicted using a structure-function model based upon collagen fiber architecture. This study will establish a design paradigm for functional TECs in load-bearing applications. Ultimately, clinical success of TEC function will be assessed non-invasively with structure-function models and MRI.

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Research Project (R01)
Project #
5R01EB002425-03
Application #
6929750
Study Section
Special Emphasis Panel (ZRG1-SSS-M (57))
Program Officer
Wang, Fei
Project Start
2003-09-30
Project End
2007-07-31
Budget Start
2005-08-01
Budget End
2006-07-31
Support Year
3
Fiscal Year
2005
Total Cost
$343,134
Indirect Cost
Name
University of Pennsylvania
Department
Orthopedics
Type
Schools of Medicine
DUNS #
042250712
City
Philadelphia
State
PA
Country
United States
Zip Code
19104
Li, Qing; Wang, Chao; Han, Biao et al. (2018) Impacts of maturation on the micromechanics of the meniscus extracellular matrix. J Biomech 72:252-257
Szczesny, Spencer E; Aeppli, CĂ©line; David, Alexander et al. (2018) Fatigue loading of tendon results in collagen kinking and denaturation but does not change local tissue mechanics. J Biomech 71:251-256
Heo, Su-Jin; Szczesny, Spencer E; Kim, Dong Hwa et al. (2018) Expansion of mesenchymal stem cells on electrospun scaffolds maintains stemness, mechano-responsivity, and differentiation potential. J Orthop Res 36:808-815
Li, Qing; Qu, Feini; Han, Biao et al. (2017) Micromechanical anisotropy and heterogeneity of the meniscus extracellular matrix. Acta Biomater 54:356-366
Safa, Babak N; Meadows, Kyle D; Szczesny, Spencer E et al. (2017) Exposure to buffer solution alters tendon hydration and mechanics. J Biomech 61:18-25
Lee, Andrea H; Elliott, Dawn M (2017) Freezing does not alter multiscale tendon mechanics and damage mechanisms in tension. Ann N Y Acad Sci 1409:85-94
Szczesny, Spencer E; Mauck, Robert L (2017) The Nuclear Option: Evidence Implicating the Cell Nucleus in Mechanotransduction. J Biomech Eng 139:
Szczesny, Spencer E; Fetchko, Kristen L; Dodge, George R et al. (2017) Evidence that interfibrillar load transfer in tendon is supported by small diameter fibrils and not extrafibrillar tissue components. J Orthop Res 35:2127-2134
Peloquin, John M; Santare, Michael H; Elliott, Dawn M (2016) Advances in Quantification of Meniscus Tensile Mechanics Including Nonlinearity, Yield, and Failure. J Biomech Eng 138:021002
Heo, Su-Jin; Driscoll, Tristan P; Thorpe, Stephen D et al. (2016) Differentiation alters stem cell nuclear architecture, mechanics, and mechano-sensitivity. Elife 5:

Showing the most recent 10 out of 52 publications