We propose to develop software to accurately simulate the MRI process, from spin excitation through image reconstruction, with rigorous implementation of the physical laws of MRI and accurate 3D representations of human anatomies, field distributions, and tissue spin magnetization and relaxation properties. The output will be realistic images, accurately representing signal, contrast, and noise distributions, static and RF field-related artifacts (among many other things) for the chosen sample, sequence, and fields. This will facilitate an intermediate, low-cost stage of evaluation, revision, and optimization before implementation of novel hardware, pulses, or sequences on an MRI system. For use with the software, we will provide a library of realistic static, gradient, and RF magnetic field distributions at several field strengths from 1.0 to 9.4 tesla, human anatomies, basic pulse sequences, and reconstruction methods. The user will also be able to input specially-designed subject anatomies, different tissue spin magnetization/relaxation properties, novel field distributions at any field strength, exotic pulse sequences, and/or new reconstruction methods. The software will also calculate the head-average and maximum local Specific energy Absorption Rates (SAR) for the desired pulse sequence for comparison to safety regulations. All will be freely available and open-source so researchers can make modifications for their specific needs. Relevance: Advances in MRI have made it an invaluable tool in medicine and research in recent years, saving both lives and cost of care with accurate non-invasive diagnostic, anatomic, and physiologic information. Continual effort is devoted to improving MRI by using higher static field strengths, and thus higher RF field frequencies, but distortions of the applied fields by the human body present significant obstacles to the advancement of MRI. With the tools we will provide it will be possible to perform critical research, development, and safety evaluation of pulses, sequences, and hardware at any field strength using computers to reduce the need for magnet time and the cost of implementing untested prototypes on actual MRI systems. It will also make an excellent tool for MR education and training. This should greatly reduce the cost and increase the speed and accessibility of advancement of MRI and allow for valuable MRI system time to be dedicated more to important medical and scientific studies and less to evaluation of technical developments. ? ? ?

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Research Project (R01)
Project #
1R01EB006563-01A1
Application #
7251621
Study Section
Special Emphasis Panel (ZRG1-SBIB-Q (50))
Program Officer
Mclaughlin, Alan Charles
Project Start
2007-09-01
Project End
2010-08-31
Budget Start
2007-09-01
Budget End
2008-08-31
Support Year
1
Fiscal Year
2007
Total Cost
$263,515
Indirect Cost
Name
Pennsylvania State University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
129348186
City
Hershey
State
PA
Country
United States
Zip Code
17033
Yu, Zidan; Xin, Xuegang; Collins, Christopher M (2017) Potential for high-permittivity materials to reduce local SAR at a pacemaker lead tip during MRI of the head with a body transmit coil at 3?T. Magn Reson Med 78:383-386
Cao, Zhipeng; Oh, Sukhoon; Otazo, Ricardo et al. (2015) Complex difference constrained compressed sensing reconstruction for accelerated PRF thermometry with application to MRI-induced RF heating. Magn Reson Med 73:1420-31
Cao, Zhipeng; Park, Joshua; Cho, Zang-Hee et al. (2015) Numerical evaluation of image homogeneity, signal-to-noise ratio, and specific absorption rate for human brain imaging at 1.5, 3, 7, 10.5, and 14T in an 8-channel transmit/receive array. J Magn Reson Imaging 41:1432-9
Cao, Zhipeng; Oh, Sukhoon; Sica, Christopher T et al. (2014) Bloch-based MRI system simulator considering realistic electromagnetic fields for calculation of signal, noise, and specific absorption rate. Magn Reson Med 72:237-47
Oh, Sukhoon; Ryu, Yeun-Chul; Carluccio, Giuseppe et al. (2014) Measurement of SAR-induced temperature increase in a phantom and in vivo with comparison to numerical simulation. Magn Reson Med 71:1923-31
Luo, Wei; Lanagan, Michael T; Sica, Christopher T et al. (2013) Permittivity and performance of dielectric pads with sintered ceramic beads in MRI: early experiments and simulations at 3 T. Magn Reson Med 70:269-75
Fowler, Robert Andrew; Fossheim, Sigrid L; Mestas, Jean-Louis et al. (2013) Non-invasive magnetic resonance imaging follow-up of sono-sensitive liposome tumor delivery and controlled release after high-intensity focused ultrasound. Ultrasound Med Biol 39:2342-50
Collins, Christopher M; Wang, Zhangwei (2011) Calculation of radiofrequency electromagnetic fields and their effects in MRI of human subjects. Magn Reson Med 65:1470-82