? EIT is a new medical imaging method. Tomographic images of the electrical properties of a subject are produced with a box of electronics about the size of a DVD player, and EGG type electrodes placed around the head, chest or abdomen. Small, insensible, electrical signals are applied to the electrodes and sophisticated mathematical methods translate these into images with a PC in real time. It is portable, inexpensive, safe, and rapid. Unlike EEG source modelling, the images are unique; reconstruction is almost identical to that of optical tomography. Over the past two decades, the applicant has pioneered the use of EIT for imaging brain function. Most work has been into EIT to image the larger changes in impedance which occur related to changes in blood flow and cell swelling over seconds, as in stroke or epileptic seizures. EIT also has the unique potential to image the small impedance changes which occur in the brain as ion channels open during neuronal depolarization. There are strong grounds for believing that this is possible : Biophysical modelling indicates such activity changes resistance by 1% locally in the brain; the model has been validated in crab nerve recording, such changes are imageable in saline filled tanks, and detailed modelling of volume conducted fields indicates signals just large enough for reliable detection on the scalp. So far, human studies recording voltage or magnetic fields with Magnetoencephalography have shown marginal changes but have not been optimised. The purpose of this application is to validate the physiological basis of this method by recording these fast impedance changes in animals with implanted electrodes, during evoked normal activity. The method will be refined and then assessed for imaging accuracy in humans with indwelling electrodes already implanted for epilepsy surgery. If successful, this will set the foundation for the ultimate goal of future recordings non-invasively in humans. If successful, this would produce a revolutionary new non-invasive method for imaging the fast electrical activity over milliseconds which is the true basis of brain activity, with an inexpensive portable imaging device. It would enable a much deeper understanding of how the brain works, as it would enable mathematical analysis of the fast electrical activity in pathways in the brain. This would lead to radical improvements in understanding and treatment of disorders like schizophrenia, depression and epilepsy. ? ? ?

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Research Project (R01)
Project #
5R01EB006597-03
Application #
7485104
Study Section
Special Emphasis Panel (ZEB1-OSR-A (M1))
Program Officer
Liu, Guoying
Project Start
2006-09-15
Project End
2010-08-31
Budget Start
2008-09-01
Budget End
2010-08-31
Support Year
3
Fiscal Year
2008
Total Cost
$291,301
Indirect Cost
Name
University College London
Department
Type
DUNS #
225410919
City
London
State
Country
United Kingdom
Zip Code
WC1 -6BT
Packham, B; Barnes, G; Dos Santos, G Sato et al. (2016) Empirical validation of statistical parametric mapping for group imaging of fast neural activity using electrical impedance tomography. Physiol Meas 37:951-67
Oh, T; Gilad, O; Ghosh, A et al. (2011) A novel method for recording neuronal depolarization with recording at 125-825 Hz: implications for imaging fast neural activity in the brain with electrical impedance tomography. Med Biol Eng Comput 49:593-604
Gilad, O; Holder, D S (2009) Impedance changes recorded with scalp electrodes during visual evoked responses: implications for Electrical Impedance Tomography of fast neural activity. Neuroimage 47:514-22
Fabrizi, L; McEwan, A; Oh, T et al. (2009) A comparison of two EIT systems suitable for imaging impedance changes in epilepsy. Physiol Meas 30:S103-20
Gilad, O; Horesh, L; Holder, D S (2009) A modelling study to inform specification and optimal electrode placement for imaging of neuronal depolarization during visual evoked responses by electrical and magnetic detection impedance tomography. Physiol Meas 30:S201-24
Fabrizi, L; McEwan, A; Oh, T et al. (2009) An electrode addressing protocol for imaging brain function with electrical impedance tomography using a 16-channel semi-parallel system. Physiol Meas 30:S85-101
Gilad, Ori; Ghosh, Anthony; Oh, Dongin et al. (2009) A method for recording resistance changes non-invasively during neuronal depolarization with a view to imaging brain activity with electrical impedance tomography. J Neurosci Methods 180:87-96
Gilad, O; Horesh, L; Holder, D S (2007) Design of electrodes and current limits for low frequency electrical impedance tomography of the brain. Med Biol Eng Comput 45:621-33