Both fluoroscopy and computed tomography are becoming increasingly utilized in pediatric medicine. Quantitative methods for determining organ dose in pediatric patients are thus essential for clinical decision-making and risk assessment. Even approximate methods of risk assessment, based upon measures of entrance dose or energy imparted, fundamentally rely upon knowledge or organ dose. Organ doses may be determined through either computational simulation of the diagnostic exam using anthropomorphic models, or through the use of dosimeters embedded within anthropomorphic physical phantoms. Anthropomorphic computational models may be further classified as either stylized models, where organs are delineated by 3D surface equations, or tomographic models, in which organs are determined from segmented CT or MRI images. In this project, the investigators will develop improved techniques for estimating organ doses to the newborn child in both fluoroscopic and CT examinations. The project Specific Aims are: 1) to construct a high-resolution, segmented tomographic computational model of a newborn child using helical CT images of live newborns. The model will be scaled to match the dimensions and organ masses of the MIRD newborn model; 2) to construct a high-resolution tomographic physical phantom of a live newborn using the identical CT data and also scaled to match the MIRD newborn model. A full-scale physical phantom of the stylized MIRD model will also be constructed. Internal organ doses will be assessed using embedded high-sensitivity MOSFET dosimeters; 3) to determine organ doses in the newborn child received during fluoroscopic and CT examinations using both the computational model and physical phantoms developed in Specific Aims 1 and 2, respectively; and 4) to evaluate the degree to which improved anatomic representation, in either computational models or physical phantoms, influences estimates of organ dose in newborn radiological examinations.

Agency
National Institute of Health (NIH)
Institute
Eunice Kennedy Shriver National Institute of Child Health & Human Development (NICHD)
Type
Research Project (R01)
Project #
1R01HD038932-01
Application #
6094071
Study Section
Diagnostic Imaging Study Section (DMG)
Program Officer
Willinger, Marian
Project Start
2000-05-01
Project End
2003-04-30
Budget Start
2000-05-01
Budget End
2001-04-30
Support Year
1
Fiscal Year
2000
Total Cost
$221,234
Indirect Cost
Name
University of Florida
Department
Engineering (All Types)
Type
Schools of Engineering
DUNS #
073130411
City
Gainesville
State
FL
Country
United States
Zip Code
32611
Pazik, Frank D; Staton, Robert J; Williams, Jonathon L et al. (2007) Organ and effective doses in newborns and infants undergoing voiding cystourethrograms (VCUG): a comparison of stylized and tomographic phantoms. Med Phys 34:294-306
Lee, Choonik; Lee, Choonsik; Staton, Robert J et al. (2007) Organ and effective doses in pediatric patients undergoing helical multislice computed tomography examination. Med Phys 34:1858-73
Staton, Robert J; Williams, Jonathon L; Arreola, Manuel M et al. (2007) Organ and effective doses in infants undergoing upper gastrointestinal (UGI) fluoroscopic examination. Med Phys 34:703-10
Jones, A K; Simon, T A; Bolch, W E et al. (2006) Tomographic physical phantom of the newborn child with real-time dosimetry I. Methods and techniques for construction. Med Phys 33:3274-82
Staton, Robert J; Jones, A Kyle; Lee, Choonik et al. (2006) A tomographic physical phantom of the newborn child with real-time dosimetry. II. Scaling factors for calculation of mean organ dose in pediatric radiography. Med Phys 33:3283-9
Lee, Choonik; Lee, Choonsik; Shah, Amish P et al. (2006) An assessment of bone marrow and bone endosteum dosimetry methods for photon sources. Phys Med Biol 51:5391-407
Lee, Choonik; Lee, Choonsik; Williams, Jonathan L et al. (2006) Whole-body voxel phantoms of paediatric patients--UF Series B. Phys Med Biol 51:4649-61
Staton, Robert J; Lee, Choonik; Lee, Choonsik et al. (2006) Organ and effective doses in newborn patients during helical multislice computed tomography examination. Phys Med Biol 51:5151-66
Lee, Choonik; Lee, Choonsik; Bolch, Wesley E (2006) Age-dependent organ and effective dose coefficients for external photons: a comparison of stylized and voxel-based paediatric phantoms. Phys Med Biol 51:4663-88
Jones, A K; Pazik, F D; Hintenlang, D E et al. (2005) MOSFET dosimeter depth-dose measurements in heterogeneous tissue-equivalent phantoms at diagnostic x-ray energies. Med Phys 32:3209-13

Showing the most recent 10 out of 16 publications