Radiation therapy plays a key role in the loco-regional management of patients with high- grade STS. Currently, T2-weighted Magnetic Resonance Imaging (MR) is the modality of choice in the treatment planning of STS. Unfortunately, peri-tumoral edema in soft STS can extend up to 4 cm from the T2 gross tumor. This is the reason why the current radiation therapy oncology group (RTOG) consensus a volume that exceeds MRI defined tumor dimension by 3.5 cm longitudinally and 1.5 cm radially. Additional T1-weighted contrast enhanced suspicious edemas are usually added to the expansion that can be further problematic given the extensive T1 abnormalities associated with many of these lesions and extra cost of T1-weighted dynamic study. In some cases, high dose radiation can be difficult in the management of STS because the morbidity would be unacceptable or nearby critical organs make extended radiation impossible. Thus, it becomes clear why the morbidity associated with STS is so prohibitive. Our proposal tackles this very important question. Instead of standard anatomical based MRI delineation, metabolic oncologic imaging with FDG-PET or MRS has been shown to higher sensitivity and specificity. By using the strengths of combined PET and MRI/MRS, we propose to define a more accurate delineation of suspicious peri-tumoral edema for preoperative radiation therapy Clinical Target Volume (CTV). If successful, the impact of our work will be substantial as it would reduce the CTV of radiation therapy, and the associated morbidity, without compromising the treatment efficacy and while allowing greater specificity is assessing response to treatment that can be achieved with PET or MRS alone.

Public Health Relevance

The overall goal of this project is to develop and validate a novel image guidance approach to radiotherapy of soft tissue sarcomas (STS) for accurate clinical target delineation and assessment of treatment response using simultaneous Positron Emission Tomography (PET) and Magnetic Resonance Spectroscopy (MRS).

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Exploratory/Developmental Grants (R21)
Project #
1R21EB021710-01A1
Application #
9187523
Study Section
Radiation Therapeutics and Biology Study Section (RTB)
Program Officer
Sastre, Antonio
Project Start
2016-07-01
Project End
2018-04-30
Budget Start
2016-07-01
Budget End
2017-04-30
Support Year
1
Fiscal Year
2016
Total Cost
$256,500
Indirect Cost
$106,500
Name
Massachusetts General Hospital
Department
Type
DUNS #
073130411
City
Boston
State
MA
Country
United States
Zip Code
02114
Han, Paul Kyu; Ma, Chao; Deng, Kexin et al. (2018) A minimum-phase Shinnar-Le Roux spectral-spatial excitation RF pulse for simultaneous water and lipid suppression in 1H-MRSI of body extremities. Magn Reson Imaging 45:18-25
Ma, Chao; Clifford, Bryan; Liu, Yuchi et al. (2017) High-resolution dynamic 31 P-MRSI using a low-rank tensor model. Magn Reson Med 78:419-428
Ma, Chao; Lam, Fan; Ning, Qiang et al. (2017) High-resolution 1 H-MRSI of the brain using short-TE SPICE. Magn Reson Med 77:467-479
Petibon, Yoann; Guehl, Nicolas J; Reese, Timothy G et al. (2017) Impact of motion and partial volume effects correction on PET myocardial perfusion imaging using simultaneous PET-MR. Phys Med Biol 62:326-343
He, Jingfei; Liu, Qiegen; Christodoulou, Anthony G et al. (2016) Accelerated High-Dimensional MR Imaging With Sparse Sampling Using Low-Rank Tensors. IEEE Trans Med Imaging 35:2119-29
Zhang, Xiaomeng; Chen, Yen-Lin E; Lim, Ruth et al. (2016) Synergistic role of simultaneous PET/MRI-MRS in soft tissue sarcoma metabolism imaging. Magn Reson Imaging 34:276-9
Lam, Fan; Ma, Chao; Clifford, Bryan et al. (2016) High-resolution (1) H-MRSI of the brain using SPICE: Data acquisition and image reconstruction. Magn Reson Med 76:1059-70