We are developing a fast, low-dose, direct-conversion x-ray detector for pre-clinical small animal imaging. The detector will improve micro-CT imaging of animal and specimen with fast readout, reduced dose, high throughput, and low detector cost. It can be incorporated into micro-CT systems to reduce the radiation dose delivered to animals and will enable new procedures that are not currently feasible due to the characteristics of present x-ray detectors. Micro-CT scanners have become integral to the study of disease progression and to drug development in small animals. By combining the ease of animal studies with the high resolution of small-animal CT, research is faster and at a lower cost than with conventional techniques. Manufacturers of functional imaging systems such as microPET and microSPECT (1) are also integrating micro-CT detectors into their systems for localizing functional activity anatomically, performing attenuation correction, and for enabling CT-based diagnostics. Although these systems enable longitudinal studies, multiple micro-CT scans deliver a large radiation dose to the animal, which can perturb the intended experiment or even kill the subject. The dose efficiency of current scintillator-CCD or -CMOS photodiode array x-ray detectors is compromised by inefficient conversion of x-rays to light, transport of the light to the detector, and conversion of the light to electric signal. We have successfully developed a new direct x-ray converter material, polycrystalline mercuric iodide, which is a high-Z large bandgap compound semiconductor with outstanding charge collection properties. The proposed detector is a thin film of poly- crystalline mercuric iodide for direct conversion of incident x-rays into charge, coupled to a CMOS readout structure for charge readout. Dose reduction and improved throughput will be achieved due to the very high sensitivity of mercuric iodide films. We expect to widely market the device as an OEM component to scanner manufacturers. In Phase I of the project, we developed a specialized high-speed large-area CMOS readout chip specially designed for compatibility with Hgl2. In this Phase II we will customize the design of the CMOS readout chip for full optimization, modify the Hgl2 deposition as required, and complete and test a product prototype. Testing of detector prototypes will be performed at both Gamma Medica and UCLA Children's Hospital in their small animal CT/SPECT systems. ? ? ?

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Small Business Innovation Research Grants (SBIR) - Phase II (R44)
Project #
5R44EB003058-03
Application #
7254912
Study Section
Special Emphasis Panel (ZRG1-SBMI-F (10))
Program Officer
Lopez, Hector
Project Start
2004-02-04
Project End
2008-11-28
Budget Start
2007-07-01
Budget End
2008-11-28
Support Year
3
Fiscal Year
2007
Total Cost
$369,222
Indirect Cost
Name
Dxray, Inc.
Department
Type
DUNS #
153098871
City
Northridge
State
CA
Country
United States
Zip Code
91324
Hartsough, Neal E; Iwanczyk, Jan S; Nygard, Einar et al. (2009) Polycrystalline Mercuric Iodide Films on CMOS Readout Arrays. IEEE Trans Nucl Sci 56:1810-1816