The objective of the Biocompatibility Core is to provide complete pre-clinical biocompatibility testing for all dental resins and composites produced in the program project as well as for all new chemicals used in preparation of program project materials. Specifically the specific aims are: 1) to perform standard in vitro tests for assessment of cytotoxicity and mutagenicity; 2) to perform additional in vitro testing that will provide broader biocompatibility assessment at the level of endocrine disrupting activity and pro-inflammatory activities derived from components used in the preparation of resins and composites in the program project; 3) to perform in vivo tests in experimental animals to establish the irritation, sensitization and subchronic toxicity of materials of interest to the program project; and 4) to determine leachable components through the analysis of extracts from dental resins prepared in the program project. All biocompatibility testing will be conducted under Good Laboratory Practices (GLP) to support clinical studies of final products in humans. Standard tests will be performed as recommended for surface contacting devices and as specified in the ISO 7405 and ANSI/ADA document 41. The additional in vitro tests such as the ICSM-1-dependent inmunotoxicity testing were developed in the program project during past funding periods and now have become part of the Biocompatibilty Core activity. Standard tests will also be applied to materials that have been under-cured so as to evaluate potential misuse leading to bio-incompatibility. We anticipate testing an average of 16 specimens per year. A specimen includes new polmeric material (resin or composite), all new components and reference compounds. In vivo testing will increase during the later stages of the program project. The significance of the Biocompatibility Core activities are that individual components and the assembled dental adhesive and composite systems will have a well defined, regulatory acceptable, biocompatibility prior to clinical use assuring the safety for each patient.

Project Start
Project End
Budget Start
Budget End
Support Year
13
Fiscal Year
2003
Total Cost
$113,856
Indirect Cost
Name
University of Missouri Kansas City
Department
Type
DUNS #
010989619
City
Kansas City
State
MO
Country
United States
Zip Code
64110
Eick, J David; Barragan-Adjemian, Cielo; Rosser, Jennifer et al. (2012) Silorane resin supports proliferation, differentiation, and mineralization of MLO-A5 bone cells in vitro and bone formation in vivo. J Biomed Mater Res B Appl Biomater 100:850-61
Miller, Matthew D; Holder, Andrew J; Kilway, Kathleen V et al. (2006) Quantum-Mechanical QSPR Models for Polymerization Volume Change of Epoxides and Methacrylates Based on Mercury Dilatometry Results. Polymer (Guildf) 47:8595-8603
Yourtee, D M; Smith, R E; Russo, K A et al. (2001) The stability of methacrylate biomaterials when enzyme challenged: kinetic and systematic evaluations. J Biomed Mater Res 57:522-31
Yourtee, D M; Tong, P Y; Rose, L A et al. (1994) The effect of spiroorthocarbonate volume modifier co-monomers on the in vitro toxicology of trial non-shrinking dental epoxy co-polymers. Res Commun Mol Pathol Pharmacol 86:347-60
Smith, R E; Yourtee, D; Bean, T et al. (1993) Ion chromatography on a new moderate capacity anion exchange column. J Chromatogr Sci 31:366-70
Eick, J D; Robinson, S J; Cobb, C M et al. (1992) The dentinal surface: its influence on dentinal adhesion. 2. Quintessence Int 23:43-51
Eick, J D; Cobb, C M; Chappell, R P et al. (1991) The dentinal surface: its influence on dentinal adhesion. Part I. Quintessence Int 22:967-77