The overall goal of the National Center of Image-guided Therapy (NCIGT) is to develop novel tumor localization and targeting technologies for achieving complete resection or focal ablation of cancer with preservation of structure and function of adjacent normal tissues. We will achieve this by improving tumor characterization with accurate definition of its margin, localization and targeting of diseased tissue, and using image guidance technologies to optimize surgical and interventional treatments for improving outcomes and decreasing complications by reducing adjacent tissue damage. We have four TR&Ds: The Prostate TR&D will develop novel platforms to allow for molecular profiling of prostate cancer and imaging to allow for improved predictive markers for guiding biopsy and focal therapy, and by use of image processing methods for monitoring treatment effect. The Neurosurgery TR&D will use a molecular biomarker, mass spectrometry, for intraoperative surgical decision making to better define tumor extent. Advanced functional mapping using fMRI+DTI will be used for individualized treatment planning. The Computation TR&D will develop specialized multimodal image registration algorithms and custom hardware for motion compensation to improve tumor localization and functional mapping. The Guidance TR&D will develop novel instrument and tumor tracking technologies to accurately deliver therapy despite significant physiological motion and tissue deformation. The proposed Image-Guided Therapy methods that introduce new ways to visualize images, guide procedures, and track changes will be integrated with our open source software platform, 3D Slicer.

Public Health Relevance

The main challenge of tumor surgeries is to achieve the complete removal or destruction of tumors with minimal or no damage to adjacent normal tissues and their functions. There are several obstacles and limitations that prevent us to realize this vision of 'ideal precision surgery'. We propose new, innovative technological solutions for more effective and at the same time less invasive tumor treatment solutions that can provide better outcomes with much less complications than current surgical and/or interventional methods.

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Biotechnology Resource Grants (P41)
Project #
5P41EB015898-15
Application #
9747286
Study Section
Special Emphasis Panel (ZEB1)
Program Officer
Duan, Qi
Project Start
2004-04-01
Project End
2021-06-30
Budget Start
2019-07-01
Budget End
2021-06-30
Support Year
15
Fiscal Year
2019
Total Cost
Indirect Cost
Name
Brigham and Women's Hospital
Department
Type
DUNS #
030811269
City
Boston
State
MA
Country
United States
Zip Code
02115
Newitt, David C; Malyarenko, Dariya; Chenevert, Thomas L et al. (2018) Multisite concordance of apparent diffusion coefficient measurements across the NCI Quantitative Imaging Network. J Med Imaging (Bellingham) 5:011003
Taghipour, Mehdi; Ziaei, Alireza; Alessandrino, Francesco et al. (2018) Investigating the role of DCE-MRI, over T2 and DWI, in accurate PI-RADS v2 assessment of clinically significant peripheral zone prostate lesions as defined at radical prostatectomy. Abdom Radiol (NY) :
Peled, Sharon; Vangel, Mark; Kikinis, Ron et al. (2018) Selection of Fitting Model and Arterial Input Function for Repeatability in Dynamic Contrast-Enhanced Prostate MRI. Acad Radiol :
Cheng, Cheng-Chieh; Preiswerk, Frank; Hoge, W Scott et al. (2018) Multipathway multi-echo (MPME) imaging: all main MR parameters mapped based on a single 3D scan. Magn Reson Med :
Lasso, Andras; Nam, Hannah H; Dinh, Patrick V et al. (2018) Interaction with Volume-Rendered Three-Dimensional Echocardiographic Images in Virtual Reality. J Am Soc Echocardiogr 31:1158-1160
Tokuda, Junichi; Chauvin, Laurent; Ninni, Brian et al. (2018) Motion compensation for MRI-compatible patient-mounted needle guide device: estimation of targeting accuracy in MRI-guided kidney cryoablations. Phys Med Biol 63:085010
Yengul, Sanjay S; Barbone, Paul E; Madore, Bruno (2018) Dispersion in Tissue-Mimicking Gels Measured with Shear Wave Elastography and Torsional Vibration Rheometry. Ultrasound Med Biol :
Zhang, Fan; Wu, Weining; Ning, Lipeng et al. (2018) Suprathreshold fiber cluster statistics: Leveraging white matter geometry to enhance tractography statistical analysis. Neuroimage 171:341-354
Moreira, Pedro; Patel, Niravkumar; Wartenberg, Marek et al. (2018) Evaluation of robot-assisted MRI-guided prostate biopsy: needle path analysis during clinical trials. Phys Med Biol 63:20NT02
Black, David; Hahn, Horst K; Kikinis, Ron et al. (2018) Auditory display for fluorescence-guided open brain tumor surgery. Int J Comput Assist Radiol Surg 13:25-35

Showing the most recent 10 out of 286 publications