We have developed a stopped-flow flow cytometer with subsecond resolution to be used in kinetic analysis of cell activation. This instrument is extending the application of flow cytometry to important biological molecules that interact with cell surface receptors or can be linked to beads. The device is making it possible to examine the kinetics of interaction of a variety of macromolecular assemblies. In year 16, we have shown that the stability of sample flow can be improved in the subsecond time frame by using automated syringes to simultaneously control sample flow and sheath flow (Seamer, Kuckuck and Sklar, manuscript acceptable with revision). A new five syringe mixing device has been designed and manufactured to take advantage of this improved stability for kinetic analysis.
Frumkin, Jesse P; Patra, Biranchi N; Sevold, Anthony et al. (2016) The interplay between chromosome stability and cell cycle control explored through gene-gene interaction and computational simulation. Nucleic Acids Res 44:8073-85 |
Johnson, Leah M; Gao, Lu; Shields IV, C Wyatt et al. (2013) Elastomeric microparticles for acoustic mediated bioseparations. J Nanobiotechnology 11:22 |
Micheva-Viteva, Sofiya N; Shou, Yulin; Nowak-Lovato, Kristy L et al. (2013) c-KIT signaling is targeted by pathogenic Yersinia to suppress the host immune response. BMC Microbiol 13:249 |
Ai, Ye; Sanders, Claire K; Marrone, Babetta L (2013) Separation of Escherichia coli bacteria from peripheral blood mononuclear cells using standing surface acoustic waves. Anal Chem 85:9126-34 |
Sanders, Claire K; Mourant, Judith R (2013) Advantages of full spectrum flow cytometry. J Biomed Opt 18:037004 |
Cushing, Kevin W; Piyasena, Menake E; Carroll, Nick J et al. (2013) Elastomeric negative acoustic contrast particles for affinity capture assays. Anal Chem 85:2208-15 |
Piyasena, Menake E; Austin Suthanthiraraj, Pearlson P; Applegate Jr, Robert W et al. (2012) Multinode acoustic focusing for parallel flow cytometry. Anal Chem 84:1831-9 |
Austin Suthanthiraraj, Pearlson P; Piyasena, Menake E; Woods, Travis A et al. (2012) One-dimensional acoustic standing waves in rectangular channels for flow cytometry. Methods 57:259-71 |
Vuyisich, Momchilo; Sanders, Claire K; Graves, Steven W (2012) Binding and cell intoxication studies of anthrax lethal toxin. Mol Biol Rep 39:5897-903 |
Chaudhary, Anu; Ganguly, Kumkum; Cabantous, Stephanie et al. (2012) The Brucella TIR-like protein TcpB interacts with the death domain of MyD88. Biochem Biophys Res Commun 417:299-304 |
Showing the most recent 10 out of 240 publications