The Department of Electrical Engineering, Magnetic Resonance and Spectrscopy Research Laboratory, has benefited from the fruitful interaction with the Lucas Center. Methods A major project in the MRSRL is the development of new noninvasive methods for blood vessel imaging of the neck, abdomen, and legs. Because vessel disease in these regions is correlated with highly prevalent ailments such as stroke, hypertension, and thrombosis, a noninvasive imaging procedure would be of enormous utility. Our purpose is to develop faster and more accurate methods for MR vessel imaging. Compared to invasive x-ray methods of blood vessel imaging which involve radiation, the injection of contrast material, and the presence of a skilled physician, MR offers a safe, painless method that is relatively easy to perform. Although MR vessel imaging methods have developed significantly over the past few years, their clinical impact remains far short of their potential. We have been pursuing improved MR methods that address some of the primary shortcomings plaguing existing MR methods. These problems include relatively long scan times, limited spatial resolution, and artifactual signal loss in regions of narrowing. We are investigating several new methods for generating higher vessel contrast and 3D imaging. Discussion Overall, compared to existing methods, our methods offer performance advantages in speed, accuracy, and vessel contrast, but their implementation is more difficult. A major challenge has been to design the MR pulse sequence and image reconstruction software carefully. Many methods have recently undergone refinement using normal volunteers and are moving on to initial evaluation at the Lucas Center on selected patients with known disease. Besides image quality issues (e.g spatial resolution, vessel contrast), an important area of evaluation is the ease-of-use of the scan protocol. The continual feedback of radiologists is essential to this project.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR009784-02
Application #
5225806
Study Section
Project Start
Project End
Budget Start
Budget End
Support Year
2
Fiscal Year
1996
Total Cost
Indirect Cost
Maclaren, Julian; Aksoy, Murat; Ooi, Melvyn B et al. (2018) Prospective motion correction using coil-mounted cameras: Cross-calibration considerations. Magn Reson Med 79:1911-1921
Guo, Jia; Holdsworth, Samantha J; Fan, Audrey P et al. (2018) Comparing accuracy and reproducibility of sequential and Hadamard-encoded multidelay pseudocontinuous arterial spin labeling for measuring cerebral blood flow and arterial transit time in healthy subjects: A simulation and in vivo study. J Magn Reson Imaging 47:1119-1132
Tamir, Jonathan I; Uecker, Martin; Chen, Weitian et al. (2017) T2 shuffling: Sharp, multicontrast, volumetric fast spin-echo imaging. Magn Reson Med 77:180-195
Lai, Lillian M; Cheng, Joseph Y; Alley, Marcus T et al. (2017) Feasibility of ferumoxytol-enhanced neonatal and young infant cardiac MRI without general anesthesia. J Magn Reson Imaging 45:1407-1418
Taviani, Valentina; Alley, Marcus T; Banerjee, Suchandrima et al. (2017) High-resolution diffusion-weighted imaging of the breast with multiband 2D radiofrequency pulses and a generalized parallel imaging reconstruction. Magn Reson Med 77:209-220
Uecker, Martin; Lustig, Michael (2017) Estimating absolute-phase maps using ESPIRiT and virtual conjugate coils. Magn Reson Med 77:1201-1207
Kogan, Feliks; Hargreaves, Brian A; Gold, Garry E (2017) Volumetric multislice gagCEST imaging of articular cartilage: Optimization and comparison with T1rho. Magn Reson Med 77:1134-1141
Aksoy, Murat; Maclaren, Julian; Bammer, Roland (2017) Prospective motion correction for 3D pseudo-continuous arterial spin labeling using an external optical tracking system. Magn Reson Imaging 39:44-52
Bian, W; Tranvinh, E; Tourdias, T et al. (2016) In Vivo 7T MR Quantitative Susceptibility Mapping Reveals Opposite Susceptibility Contrast between Cortical and White Matter Lesions in Multiple Sclerosis. AJNR Am J Neuroradiol 37:1808-1815
Vos, Sjoerd B; Aksoy, Murat; Han, Zhaoying et al. (2016) Trade-off between angular and spatial resolutions in in vivo fiber tractography. Neuroimage 129:117-132

Showing the most recent 10 out of 446 publications