Hemodynamic parameters such as low and oscillating blood flow rates and shear stresses have been implicated in the development of atherosclerosis and other vascular pathologies. In order to study these effects in vivo, quantitative blood flow information must be acquired with high spatial and temporal resolution to resolve pulsatile flow. Additionally, a high signal-to-noise ratio is required. Previous MR methods for measuring blood flow using phase-contrast imaging of velocity have allowed for either time-resolved 2D imaging or for non time-resolved 3D imaging. We have developed and are currently evaluating two different methods for acquiring 3D time-resolved phase contrast MR data in order to study hemodynamics in vivo. Methods and Results A cine mode to provide temporal resolution was added to a conventional gradient-recalled 3D phase contrast sequence to achieve 4-dimensional imaging. A 3D spiral sequence using a spherical stack-of-spirals k-space trajectory with gating was also evaluated. A flow phantom with a computer controlled pump capable of delivering pulsatile flow patterns was used in validating the techniques. In vivo images were obtained from the carotid bifurcation of a normal volunteer. Discussion Time-resolved, 3D flow fields can be acquired with either conventional or spiral k-space trajectories. The SNR improvement and higher slice direction resolution possible with 3D methods are advantages over a multi-slice 2D acquisition scheme. As compared to the conventional sequence, the spiral technique has significantly shorter scan times, but lower SNR. Overall, the use of these sequences for in vivo quantification of human flow dynamics is very promising and should help clarify the role of hemodynamics in the development of atherosclerosis.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR009784-02
Application #
5225777
Study Section
Project Start
Project End
Budget Start
Budget End
Support Year
2
Fiscal Year
1996
Total Cost
Indirect Cost
Maclaren, Julian; Aksoy, Murat; Ooi, Melvyn B et al. (2018) Prospective motion correction using coil-mounted cameras: Cross-calibration considerations. Magn Reson Med 79:1911-1921
Guo, Jia; Holdsworth, Samantha J; Fan, Audrey P et al. (2018) Comparing accuracy and reproducibility of sequential and Hadamard-encoded multidelay pseudocontinuous arterial spin labeling for measuring cerebral blood flow and arterial transit time in healthy subjects: A simulation and in vivo study. J Magn Reson Imaging 47:1119-1132
Tamir, Jonathan I; Uecker, Martin; Chen, Weitian et al. (2017) T2 shuffling: Sharp, multicontrast, volumetric fast spin-echo imaging. Magn Reson Med 77:180-195
Lai, Lillian M; Cheng, Joseph Y; Alley, Marcus T et al. (2017) Feasibility of ferumoxytol-enhanced neonatal and young infant cardiac MRI without general anesthesia. J Magn Reson Imaging 45:1407-1418
Taviani, Valentina; Alley, Marcus T; Banerjee, Suchandrima et al. (2017) High-resolution diffusion-weighted imaging of the breast with multiband 2D radiofrequency pulses and a generalized parallel imaging reconstruction. Magn Reson Med 77:209-220
Uecker, Martin; Lustig, Michael (2017) Estimating absolute-phase maps using ESPIRiT and virtual conjugate coils. Magn Reson Med 77:1201-1207
Kogan, Feliks; Hargreaves, Brian A; Gold, Garry E (2017) Volumetric multislice gagCEST imaging of articular cartilage: Optimization and comparison with T1rho. Magn Reson Med 77:1134-1141
Aksoy, Murat; Maclaren, Julian; Bammer, Roland (2017) Prospective motion correction for 3D pseudo-continuous arterial spin labeling using an external optical tracking system. Magn Reson Imaging 39:44-52
Suh, Ga-Young; Choi, Gilwoo; Herfkens, Robert J et al. (2016) Three-Dimensional Modeling Analysis of Visceral Arteries and Kidneys during Respiration. Ann Vasc Surg 34:250-60
Ong, Frank; Lustig, Michael (2016) Beyond Low Rank + Sparse: Multi-scale Low Rank Matrix Decomposition. IEEE J Sel Top Signal Process 10:672-687

Showing the most recent 10 out of 446 publications