Introduction: MRI detection of subarachnoid hemorrhage (SAH) is an important but controversial tool for monitoring acute stroke patients. Recent publications favorably compare FLAIR (fluid attenuated inversion recovery) MRI to computed tomography (CT) for the detection of acute SAH. However, the source of this MR image contrast is not well understood. The purpose of this study was to investigate the source of the SAH contrast by comparing FLAIR images of various blood/cerebrospinal fluid (CSF) mixtures with brain. Methods: Fresh CSF was obtained from the cisterna magna and arterial blood was obtained from the femoral artery of rats. Five sample tubes were prepared: 1) heparinized blood, 2) 50/50% nonheparinized blood in phosphor buffered saline (PBS), 3) 50/50% nonheparinized blood in CSF, 4) nonheparinized blood, and 5) pure CSF. After 4 hours of settling time, the tubes were positioned next to the head of a rat and fast spin-echo FLAIR images were acquired of in-vivo brain and the sample tubes simultaneously using a 2 T GE CSI spectrometer. Transverse (T2) and longitudinal (T1) relaxation times were also measured. Results and Conclusion: All blood clots were isointense to brain on the FLAIR images. The process of clotting causes shortening of T1 and T2 to values similar to those of brain which results in little contrast on FLAIR between clots in CSF and brain. In contrast, the cells which settled in the heparinized blood were ~50% brighter than brain on FLAIR. In addition, each of the tubes containing a clot showed a thin layer of settled blood cells which was also hyperintense. T2 values for non-clotted cells were higher than for brain but less than for CSF. Hyperintensities on FLAIR images of SAH are probably due to the unclotted portion of subarachnoid blood and are best seen using long echo times.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR009784-04
Application #
6282975
Study Section
Project Start
1998-01-01
Project End
1998-12-31
Budget Start
1997-10-01
Budget End
1998-09-30
Support Year
4
Fiscal Year
1998
Total Cost
Indirect Cost
Name
Stanford University
Department
Type
DUNS #
800771545
City
Stanford
State
CA
Country
United States
Zip Code
94305
Maclaren, Julian; Aksoy, Murat; Ooi, Melvyn B et al. (2018) Prospective motion correction using coil-mounted cameras: Cross-calibration considerations. Magn Reson Med 79:1911-1921
Guo, Jia; Holdsworth, Samantha J; Fan, Audrey P et al. (2018) Comparing accuracy and reproducibility of sequential and Hadamard-encoded multidelay pseudocontinuous arterial spin labeling for measuring cerebral blood flow and arterial transit time in healthy subjects: A simulation and in vivo study. J Magn Reson Imaging 47:1119-1132
Tamir, Jonathan I; Uecker, Martin; Chen, Weitian et al. (2017) T2 shuffling: Sharp, multicontrast, volumetric fast spin-echo imaging. Magn Reson Med 77:180-195
Lai, Lillian M; Cheng, Joseph Y; Alley, Marcus T et al. (2017) Feasibility of ferumoxytol-enhanced neonatal and young infant cardiac MRI without general anesthesia. J Magn Reson Imaging 45:1407-1418
Taviani, Valentina; Alley, Marcus T; Banerjee, Suchandrima et al. (2017) High-resolution diffusion-weighted imaging of the breast with multiband 2D radiofrequency pulses and a generalized parallel imaging reconstruction. Magn Reson Med 77:209-220
Uecker, Martin; Lustig, Michael (2017) Estimating absolute-phase maps using ESPIRiT and virtual conjugate coils. Magn Reson Med 77:1201-1207
Kogan, Feliks; Hargreaves, Brian A; Gold, Garry E (2017) Volumetric multislice gagCEST imaging of articular cartilage: Optimization and comparison with T1rho. Magn Reson Med 77:1134-1141
Aksoy, Murat; Maclaren, Julian; Bammer, Roland (2017) Prospective motion correction for 3D pseudo-continuous arterial spin labeling using an external optical tracking system. Magn Reson Imaging 39:44-52
Bian, W; Tranvinh, E; Tourdias, T et al. (2016) In Vivo 7T MR Quantitative Susceptibility Mapping Reveals Opposite Susceptibility Contrast between Cortical and White Matter Lesions in Multiple Sclerosis. AJNR Am J Neuroradiol 37:1808-1815
Vos, Sjoerd B; Aksoy, Murat; Han, Zhaoying et al. (2016) Trade-off between angular and spatial resolutions in in vivo fiber tractography. Neuroimage 129:117-132

Showing the most recent 10 out of 446 publications