This subproject is one of many research subprojects utilizing the resources provided by a Center grant funded by NIH/NCRR. The subproject and investigator (PI) may have received primary funding from another NIH source, and thus could be represented in other CRISP entries. The institution listed is for the Center, which is not necessarily the institution for the investigator. The FIRST (Functional Imaging Research Schizophrenia Testbed) Biomedical Informatics Research Network (fBIRN) program is the first-ever large scale, multi-center fMRI study of schizophrenia (www.nbirn.net). The fBIRN project will pool fMRI data from each of the 11 participating sites to enable the acquisition of a large and diverse study population in a modest time period. To maintain scanner stability, our Center developed methods in use at all the sites for periodic quality assurance (QA). Scans are performed regularly at each of the sites and data uploaded to the network servers. An abstract was prepared and accepted for ISMRM 2004. For longitudinal fMRI studies, it is important to periodically monitor scanner performance to assure that stability, geometric accuracy, signal to noise ratio (SNR) and other characteristics remain accurate and consistent. Constancy is even more important when data from multiple scanners are being compared or combined both initially and over extended periods of time, such as in the fBIRN project. QA methods developed at our Center were adapted for fBIRN. The most important of these examines scanner stability but also derives SNR and is described here. Data Acquisition The weekly stability test uses the fBIRN fMRI scan protocol with a 17 cm diameter agar phantom (35 axial, 4 mm contiguous slices, 22 cm FOV, 64x64 matrix, TE 30ms/40ms (3T-4T/1.5T), TR 3000ms, 200 time frames, 10 minute scan time, EPI or spiral). The agarose gel phantom was doped with NaCl to present RF loading typical of a head and was preferred over water to avoid swirling artifacts. Analysis Only timeseries data from the central slice (18) is used for analysis. Image intensities are measured for each time frame in the series using a 20x20 ROI centered in the image. The RMS fractional fluctuation is calculated after quadratic detrending, and drift is obtained from extrema of the trend line (Fig. 1, top). The Fourier spectrum is calculated (Fig. 1, middle). A 'Weisskoff analysis' is performed using ROIs with sizes varying from 1x1 to 20x20, as shown in Fig. 1, bottom. In this analysis, the standard deviation (STD) should decrease as ?(number of voxels in ROI) if the noise is uncorrelated. System instabilities from RF or gradient sources tend to cause low spatial-frequency image fluctuations, which are manifested as cross-correlation between voxels. This in turn causes STD to depart from linear dependence on 1/(ROI width) and hit a floor as the ROI size becomes larger, as shown in Fig. 1 (cf. with dashed line). Note that the top plot is performed with the largest ROI size, intentionally picked to represent the system limited (rather than SNR limited) noise. In addition, the signal to fluctuation noise ratio (SFNR) is measured by an ROI in a map made from (timeseries mean image)/(timeseries standard deviation image). Finally, the SNR is calculated from noise measured with an ROI in the noise image obtained by subtracting the average of the even time frames and average of the odd time frames and dividing into the mean signal.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR009784-12
Application #
7358752
Study Section
Special Emphasis Panel (ZRG1-SBIB-F (40))
Project Start
2006-06-01
Project End
2007-05-31
Budget Start
2006-06-01
Budget End
2007-05-31
Support Year
12
Fiscal Year
2006
Total Cost
$31,178
Indirect Cost
Name
Stanford University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
009214214
City
Stanford
State
CA
Country
United States
Zip Code
94305
Maclaren, Julian; Aksoy, Murat; Ooi, Melvyn B et al. (2018) Prospective motion correction using coil-mounted cameras: Cross-calibration considerations. Magn Reson Med 79:1911-1921
Guo, Jia; Holdsworth, Samantha J; Fan, Audrey P et al. (2018) Comparing accuracy and reproducibility of sequential and Hadamard-encoded multidelay pseudocontinuous arterial spin labeling for measuring cerebral blood flow and arterial transit time in healthy subjects: A simulation and in vivo study. J Magn Reson Imaging 47:1119-1132
Tamir, Jonathan I; Uecker, Martin; Chen, Weitian et al. (2017) T2 shuffling: Sharp, multicontrast, volumetric fast spin-echo imaging. Magn Reson Med 77:180-195
Lai, Lillian M; Cheng, Joseph Y; Alley, Marcus T et al. (2017) Feasibility of ferumoxytol-enhanced neonatal and young infant cardiac MRI without general anesthesia. J Magn Reson Imaging 45:1407-1418
Taviani, Valentina; Alley, Marcus T; Banerjee, Suchandrima et al. (2017) High-resolution diffusion-weighted imaging of the breast with multiband 2D radiofrequency pulses and a generalized parallel imaging reconstruction. Magn Reson Med 77:209-220
Uecker, Martin; Lustig, Michael (2017) Estimating absolute-phase maps using ESPIRiT and virtual conjugate coils. Magn Reson Med 77:1201-1207
Kogan, Feliks; Hargreaves, Brian A; Gold, Garry E (2017) Volumetric multislice gagCEST imaging of articular cartilage: Optimization and comparison with T1rho. Magn Reson Med 77:1134-1141
Aksoy, Murat; Maclaren, Julian; Bammer, Roland (2017) Prospective motion correction for 3D pseudo-continuous arterial spin labeling using an external optical tracking system. Magn Reson Imaging 39:44-52
Suh, Ga-Young; Choi, Gilwoo; Herfkens, Robert J et al. (2016) Three-Dimensional Modeling Analysis of Visceral Arteries and Kidneys during Respiration. Ann Vasc Surg 34:250-60
Ong, Frank; Lustig, Michael (2016) Beyond Low Rank + Sparse: Multi-scale Low Rank Matrix Decomposition. IEEE J Sel Top Signal Process 10:672-687

Showing the most recent 10 out of 446 publications