This subproject is one of many research subprojects utilizing the resources provided by a Center grant funded by NIH/NCRR. The subproject and investigator (PI) may have received primary funding from another NIH source, and thus could be represented in other CRISP entries. The institution listed is for the Center, which is not necessarily the institution for the investigator. MR-guided cryoablation is a promising minimally invasive therapy for prostate tumors that are soliatary and unilateral. Temperature mapping within the frozen tissue with MRI would be preferable as it would provide maps throughout the frozen area, not just at discrete thermocouple locations. Tissue R2* is a particularly promising MR parameter to quantify and relate to temperature as it appears to be relatively linear over the temperature range of interest. The purpose of this work was optimize our R2* mapping by using a PR sequence, reducing the earliest echo time to 0.1 ms, and carefully measuring and compensating for eddy currents. Methods and Discussion: Half-RF pulse excitation is used to achieve an ultra-short echo times. Both B0 and linear eddy currents induced by the selective gradients and readout gradients are measured first. This is achieved by linearly fitting the phases of signals collected with various gradient amplitudes at several off-isocenter positions. At each time point, signal phases from the same slice are first linearly fit with respect to gradient amplitude. The linear coefficients are then fit with respect to the slice position. The resultant constant terms now correspond to the phases accumulated by B0 eddy currents, while the linear coefficients corresponds to k-space trajectory traversed by the applied gradient and linear eddy currents, respectively, both normalized by the selective gradient amplitude. For excitation, linear eddy currents are corrected by pre-compensating the RF pulse, while B0 eddy currents are corrected by varying the RF phase during excitation. Eddy currents due to readout gradients are corrected during image reconstruction. To calculate the R2*, several sets of data are acquired with different TEs for the first echo. These relatively short TE intervals are designed to accurately quantify short T2*, the third echo have similar point-spread-function (PSF) for a given T2* as the first echo, and are therefore used for better calculation of R2* for tissues with longer T2*. ISMRM abstracts:
Aimi ng Lu, Bruce L. Daniel, Kim B. Pauly. Improvements in R2* Mapping During In Vivo Cryoablation.
Aimi ng Lu, Bruce L. Daniel, Kim B. Pauly. A Simple Approach to Measure and Correct for B0 and Linear Eddy Currents.
Aimi ng Lu, Bruce L. Daniel, Kim B. Pauly. Improved Slice Excitation for Ultra-short TE Imaging with B0 and Linear Eddy Current Correction. PI: Kim B. Pauly Grants: NIH CA092061, P41 RR009784

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR009784-12
Application #
7358793
Study Section
Special Emphasis Panel (ZRG1-SBIB-F (40))
Project Start
2006-06-01
Project End
2007-05-31
Budget Start
2006-06-01
Budget End
2007-05-31
Support Year
12
Fiscal Year
2006
Total Cost
$3,118
Indirect Cost
Name
Stanford University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
009214214
City
Stanford
State
CA
Country
United States
Zip Code
94305
Maclaren, Julian; Aksoy, Murat; Ooi, Melvyn B et al. (2018) Prospective motion correction using coil-mounted cameras: Cross-calibration considerations. Magn Reson Med 79:1911-1921
Guo, Jia; Holdsworth, Samantha J; Fan, Audrey P et al. (2018) Comparing accuracy and reproducibility of sequential and Hadamard-encoded multidelay pseudocontinuous arterial spin labeling for measuring cerebral blood flow and arterial transit time in healthy subjects: A simulation and in vivo study. J Magn Reson Imaging 47:1119-1132
Taviani, Valentina; Alley, Marcus T; Banerjee, Suchandrima et al. (2017) High-resolution diffusion-weighted imaging of the breast with multiband 2D radiofrequency pulses and a generalized parallel imaging reconstruction. Magn Reson Med 77:209-220
Uecker, Martin; Lustig, Michael (2017) Estimating absolute-phase maps using ESPIRiT and virtual conjugate coils. Magn Reson Med 77:1201-1207
Kogan, Feliks; Hargreaves, Brian A; Gold, Garry E (2017) Volumetric multislice gagCEST imaging of articular cartilage: Optimization and comparison with T1rho. Magn Reson Med 77:1134-1141
Aksoy, Murat; Maclaren, Julian; Bammer, Roland (2017) Prospective motion correction for 3D pseudo-continuous arterial spin labeling using an external optical tracking system. Magn Reson Imaging 39:44-52
Tamir, Jonathan I; Uecker, Martin; Chen, Weitian et al. (2017) T2 shuffling: Sharp, multicontrast, volumetric fast spin-echo imaging. Magn Reson Med 77:180-195
Lai, Lillian M; Cheng, Joseph Y; Alley, Marcus T et al. (2017) Feasibility of ferumoxytol-enhanced neonatal and young infant cardiac MRI without general anesthesia. J Magn Reson Imaging 45:1407-1418
Bian, W; Tranvinh, E; Tourdias, T et al. (2016) In Vivo 7T MR Quantitative Susceptibility Mapping Reveals Opposite Susceptibility Contrast between Cortical and White Matter Lesions in Multiple Sclerosis. AJNR Am J Neuroradiol 37:1808-1815
Vos, Sjoerd B; Aksoy, Murat; Han, Zhaoying et al. (2016) Trade-off between angular and spatial resolutions in in vivo fiber tractography. Neuroimage 129:117-132

Showing the most recent 10 out of 446 publications