This subproject is one of many research subprojects utilizing the resources provided by a Center grant funded by NIH/NCRR. The subproject and investigator (PI) may have received primary funding from another NIH source, and thus could be represented in other CRISP entries. The institution listed is for the Center, which is not necessarily the institution for the investigator. Purpose: Differentiate between infarction and susceptibility artifact surrounding parenchymal brain hemorrhage. Materials & Methods: Diffusion-weighted imaging (DWI) has proven to be extremely sensitive in the detection of acute infarction and has revolutionized stroke diagnosis.1 However, the use of single-shot echo-planar imaging (EPI) methods for high acquisition speed and minimization of motion artifacts leads to magnetic susceptibility artifacts that can obscure infarctions, especially in the region of the skull base and adjacent to the sinuses. In the setting of parenchymal hemorrhage a high-intensity rim is often seen around the hemorrhage. The dilemma is often whether this hyperintense rim represents truly infarcted tissue or a signal pile-up artifact. The anisotropy of the susceptibility artifact can help differentiate between these two situations. In general, magnetic susceptibility artifacts in single-shot EPI are most prominent in the direction of the phase-encode gradient leading to signal-pile up in this direction. One such source for local magnetic susceptibility changes can be the iron products within a hemorrhage. Therefore, the potential causes of these equivocal hyperintense rims can be differentiated by simply swapping the phase- and frequency-encoded directions and repeating the DWI scan. Regions of susceptibility artifact will change location i.e. from being most prominent on the left and right of the hemorrhage to being most prominent on the anterior and posterior margins. Regions of truly decreased diffusion due to acute infarction will not change their position. Fifty-five consecutive patients experiencing stroke-like symptoms underwent routine brain MRI, including two DWI sequences (b=1000s/mm2), with and without parallel imaging, in which the phase- and frequency-encoded directions were swapped. Two observers evaluated each study for the presence of infarction, first using only one set of DWI images, and then using both sets of DWI images. Results: Nine out of the 55 patients had parenchymal hemorrhage, based upon the formal radiology report. Only 4 of these had hemorrhage with hyperintense rim visible on DWI sequences. With only a single DWI scan available, the observers were unable to differentiate between ischemia and artifact. In these 4 cases the subsequent DWI sequence with exchanged phase- and frequency-encoded directions confirmed that the hyperintensity was due to magnetic susceptibility changes rather than to infarction. 1. Roberts TP, Rowley HA. Diffusion weighted magnetic resonance imaging in stroke. Eur J Radiol. Mar 2003;45(3):185-194.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR009784-12
Application #
7358816
Study Section
Special Emphasis Panel (ZRG1-SBIB-F (40))
Project Start
2006-06-01
Project End
2007-05-31
Budget Start
2006-06-01
Budget End
2007-05-31
Support Year
12
Fiscal Year
2006
Total Cost
$6,236
Indirect Cost
Name
Stanford University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
009214214
City
Stanford
State
CA
Country
United States
Zip Code
94305
Maclaren, Julian; Aksoy, Murat; Ooi, Melvyn B et al. (2018) Prospective motion correction using coil-mounted cameras: Cross-calibration considerations. Magn Reson Med 79:1911-1921
Guo, Jia; Holdsworth, Samantha J; Fan, Audrey P et al. (2018) Comparing accuracy and reproducibility of sequential and Hadamard-encoded multidelay pseudocontinuous arterial spin labeling for measuring cerebral blood flow and arterial transit time in healthy subjects: A simulation and in vivo study. J Magn Reson Imaging 47:1119-1132
Kogan, Feliks; Hargreaves, Brian A; Gold, Garry E (2017) Volumetric multislice gagCEST imaging of articular cartilage: Optimization and comparison with T1rho. Magn Reson Med 77:1134-1141
Aksoy, Murat; Maclaren, Julian; Bammer, Roland (2017) Prospective motion correction for 3D pseudo-continuous arterial spin labeling using an external optical tracking system. Magn Reson Imaging 39:44-52
Tamir, Jonathan I; Uecker, Martin; Chen, Weitian et al. (2017) T2 shuffling: Sharp, multicontrast, volumetric fast spin-echo imaging. Magn Reson Med 77:180-195
Lai, Lillian M; Cheng, Joseph Y; Alley, Marcus T et al. (2017) Feasibility of ferumoxytol-enhanced neonatal and young infant cardiac MRI without general anesthesia. J Magn Reson Imaging 45:1407-1418
Taviani, Valentina; Alley, Marcus T; Banerjee, Suchandrima et al. (2017) High-resolution diffusion-weighted imaging of the breast with multiband 2D radiofrequency pulses and a generalized parallel imaging reconstruction. Magn Reson Med 77:209-220
Uecker, Martin; Lustig, Michael (2017) Estimating absolute-phase maps using ESPIRiT and virtual conjugate coils. Magn Reson Med 77:1201-1207
Bian, W; Tranvinh, E; Tourdias, T et al. (2016) In Vivo 7T MR Quantitative Susceptibility Mapping Reveals Opposite Susceptibility Contrast between Cortical and White Matter Lesions in Multiple Sclerosis. AJNR Am J Neuroradiol 37:1808-1815
Vos, Sjoerd B; Aksoy, Murat; Han, Zhaoying et al. (2016) Trade-off between angular and spatial resolutions in in vivo fiber tractography. Neuroimage 129:117-132

Showing the most recent 10 out of 446 publications