This subproject is one of many research subprojects utilizing the resources provided by a Center grant funded by NIH/NCRR. The subproject and investigator (PI) may have received primary funding from another NIH source, and thus could be represented in other CRISP entries. The institution listed is for the Center, which is not necessarily the institution for the investigator. Detection of matrix changes of articular cartilage in early osteoarthritis is important for drug discovery. We studied the fesability of comparing T2, T1r, and sodium imaging in healthy volunteers and one subject with knee pain at 3.0T. T2 mapping was done with a T2-prepared spiral method. T1r imaging was performed using a continious spin-lock pulse at several locking frequencies. Sodium imaging was done with a custom surface coil and a short echo-time 3D cones trajectory. Our results indicate it is feasible to compare these methods in vivo at 3.0T for early cartilage matrix changes.Introduction: Early detection of proteoglycan depletion in cartilage is important in development of treatments for osteoarthritis. T1r imaging, or relaxation of spins under the influence of a radio-frequency field, has been shown to be sensitive to changes in the cartilage matrix . T2 mapping is thought to reflect changes in the collagen matrix of cartilage. Sodium imaging has also been used to measure proteoglycan content in cartilage. We studied the feasibility of using these techniques in vivo at 3.0T. Methods: Four volunteers (ages 34-43) were imaged in the axial plane at 3.0T on a GE Signa MRI (GE Healthcare, Milwaukee, WI) using 3-inch coil. One volunteer had a history of anterior knee pain. Measurements of T1r were made with a continuous RF spin locking pulse at the same anatomic locations with spin lock frequencies of 300, 500, 700 and 1000 Hz. The maximum spin-lock frequency in the continuous RF sequence was limited by RF power deposition limits. T2 relaxation time at the same location was measured using a T2-prepared spiral sequence. The T1r and CPMG T2 sequences had identical imaging parameters: TR of 2000 ms, 14 spiral arms, 4096 points, and bandwidth +125 kHz. In-plane resolution was 0.7 mm with a 16 cm FOV, 4 mm slice thickness. A single slice through the patella cartilage was acquired in 5 minutes with two signal averages. The T1r sequences acquired 4 spin lock times (TSL) of 3, 15, 35, and 80 ms. The CPMG T2 sequence acquired 6 echoes at approximately 6, 17, 28, 49, 71 and 92 ms. Sodium imaging was performed with a custom 3-inch surfaces coil and a short echo time """"""""cones"""""""" trajectory . Sodium acquisitions were obtained at a voxel size of 1.25x1.25x4 mm. Parameters for the scan were: TR/TE = 50/0.6 ms, FOV = 16x16x12.8cm, matrix = 128x128x32, readout time = 8 ms, alpha = 70 deg, and 16 averages for a total scan time of 17 min 8 s. T1p and T2 relaxation times for each subject were measured in 10 cartilage locations on the medial and lateral patella facets. Sodium SNR was also measured in 10 locations on the medial and lateral facets, and in an area of increased relaxation times in the subject with knee pain. Relaxation measurements and maps were created using Osirix software .

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR009784-15
Application #
7955389
Study Section
Special Emphasis Panel (ZRG1-SBIB-F (40))
Project Start
2009-06-01
Project End
2010-05-31
Budget Start
2009-06-01
Budget End
2010-05-31
Support Year
15
Fiscal Year
2009
Total Cost
$18,046
Indirect Cost
Name
Stanford University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
009214214
City
Stanford
State
CA
Country
United States
Zip Code
94305
Maclaren, Julian; Aksoy, Murat; Ooi, Melvyn B et al. (2018) Prospective motion correction using coil-mounted cameras: Cross-calibration considerations. Magn Reson Med 79:1911-1921
Guo, Jia; Holdsworth, Samantha J; Fan, Audrey P et al. (2018) Comparing accuracy and reproducibility of sequential and Hadamard-encoded multidelay pseudocontinuous arterial spin labeling for measuring cerebral blood flow and arterial transit time in healthy subjects: A simulation and in vivo study. J Magn Reson Imaging 47:1119-1132
Tamir, Jonathan I; Uecker, Martin; Chen, Weitian et al. (2017) T2 shuffling: Sharp, multicontrast, volumetric fast spin-echo imaging. Magn Reson Med 77:180-195
Lai, Lillian M; Cheng, Joseph Y; Alley, Marcus T et al. (2017) Feasibility of ferumoxytol-enhanced neonatal and young infant cardiac MRI without general anesthesia. J Magn Reson Imaging 45:1407-1418
Taviani, Valentina; Alley, Marcus T; Banerjee, Suchandrima et al. (2017) High-resolution diffusion-weighted imaging of the breast with multiband 2D radiofrequency pulses and a generalized parallel imaging reconstruction. Magn Reson Med 77:209-220
Uecker, Martin; Lustig, Michael (2017) Estimating absolute-phase maps using ESPIRiT and virtual conjugate coils. Magn Reson Med 77:1201-1207
Kogan, Feliks; Hargreaves, Brian A; Gold, Garry E (2017) Volumetric multislice gagCEST imaging of articular cartilage: Optimization and comparison with T1rho. Magn Reson Med 77:1134-1141
Aksoy, Murat; Maclaren, Julian; Bammer, Roland (2017) Prospective motion correction for 3D pseudo-continuous arterial spin labeling using an external optical tracking system. Magn Reson Imaging 39:44-52
Bian, W; Tranvinh, E; Tourdias, T et al. (2016) In Vivo 7T MR Quantitative Susceptibility Mapping Reveals Opposite Susceptibility Contrast between Cortical and White Matter Lesions in Multiple Sclerosis. AJNR Am J Neuroradiol 37:1808-1815
Vos, Sjoerd B; Aksoy, Murat; Han, Zhaoying et al. (2016) Trade-off between angular and spatial resolutions in in vivo fiber tractography. Neuroimage 129:117-132

Showing the most recent 10 out of 446 publications