This subproject is one of many research subprojects utilizing the resources provided by a Center grant funded by NIH/NCRR. Primary support for the subproject and the subproject's principal investigator may have been provided by other sources, including other NIH sources. The Total Cost listed for the subproject likely represents the estimated amount of Center infrastructure utilized by the subproject, not direct funding provided by the NCRR grant to the subproject or subproject staff. Introduction: BOLD fMRI suffers from signal dropout in frontal-orbital and lateral parietal/temporal regions from susceptibility differences between air and tissue induces intravoxel dephasing. By decreasing the slice thickness, dephasing is reduced and signal is regained, but at the expense of signal to noise ratio (SNR) in magnetically uniform regions of the brain (1). Here we introduce a novel solution: the use of Hadamard-encoding to simultaneously excite pairs of subslices that are subsequently combined incoherently using UNFOLD (2) to gain signal in dropout regions at no loss of SNR efficiency in uniform regions. Methods: Alternately applying sine- and cosine-modulated Hadamard pulses (3) in a dynamic acquisition, two sub-slices of half the desired slice thickness are excited in-phase and out-of-phase (Fig. 1). Assuming there is a phase shift of ? between subslices because of the susceptibility-induced gradients, the resulting complex-valued time series contains magnitude components , where ?i are the magnitudes of the subslice signals, and the sign alternates with time frame t because of the alternating excitation. Squaring y(t) and taking its Fourier transform, one finds a component Y1 with spectrum centered at DC corresponding to the term and a second component Y2 centered at the Nyquist frequency corresponding to (Fig. 2). Applying an UNFOLD filter H(w) to remove the Nyquist component, inverse transforming and taking the square root yields a reconstructed timeseries , i.e. the square root of the sum of squares of the two subslices. The influence of the intravoxel dephasing component ? is thereby removed. The Hadamard method was implemented in a spiral-in/out pulse sequence (4). 60 2 mm thick subslices were acquired for 128 time frames. Timeseries corresponding to 4 mm slices were obtained from the magnitude reconstructed images as above using a two-point boxcar filter ( ). Functional data were obtained at 3T using a breath hold task to elicit activation in most of the brain (5). These scans were compared to a similar conventional method. To read about other projects ongoing at the Lucas Center, please visit http://rsl.stanford.edu/ (Lucas Annual Report and ISMRM 2011 Abstracts)

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR009784-17
Application #
8362935
Study Section
Special Emphasis Panel (ZRG1-SBIB-U (40))
Project Start
2011-04-01
Project End
2012-03-31
Budget Start
2011-04-01
Budget End
2012-03-31
Support Year
17
Fiscal Year
2011
Total Cost
$19,531
Indirect Cost
Name
Stanford University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
009214214
City
Stanford
State
CA
Country
United States
Zip Code
94305
Maclaren, Julian; Aksoy, Murat; Ooi, Melvyn B et al. (2018) Prospective motion correction using coil-mounted cameras: Cross-calibration considerations. Magn Reson Med 79:1911-1921
Guo, Jia; Holdsworth, Samantha J; Fan, Audrey P et al. (2018) Comparing accuracy and reproducibility of sequential and Hadamard-encoded multidelay pseudocontinuous arterial spin labeling for measuring cerebral blood flow and arterial transit time in healthy subjects: A simulation and in vivo study. J Magn Reson Imaging 47:1119-1132
Tamir, Jonathan I; Uecker, Martin; Chen, Weitian et al. (2017) T2 shuffling: Sharp, multicontrast, volumetric fast spin-echo imaging. Magn Reson Med 77:180-195
Lai, Lillian M; Cheng, Joseph Y; Alley, Marcus T et al. (2017) Feasibility of ferumoxytol-enhanced neonatal and young infant cardiac MRI without general anesthesia. J Magn Reson Imaging 45:1407-1418
Taviani, Valentina; Alley, Marcus T; Banerjee, Suchandrima et al. (2017) High-resolution diffusion-weighted imaging of the breast with multiband 2D radiofrequency pulses and a generalized parallel imaging reconstruction. Magn Reson Med 77:209-220
Uecker, Martin; Lustig, Michael (2017) Estimating absolute-phase maps using ESPIRiT and virtual conjugate coils. Magn Reson Med 77:1201-1207
Kogan, Feliks; Hargreaves, Brian A; Gold, Garry E (2017) Volumetric multislice gagCEST imaging of articular cartilage: Optimization and comparison with T1rho. Magn Reson Med 77:1134-1141
Aksoy, Murat; Maclaren, Julian; Bammer, Roland (2017) Prospective motion correction for 3D pseudo-continuous arterial spin labeling using an external optical tracking system. Magn Reson Imaging 39:44-52
Bian, W; Tranvinh, E; Tourdias, T et al. (2016) In Vivo 7T MR Quantitative Susceptibility Mapping Reveals Opposite Susceptibility Contrast between Cortical and White Matter Lesions in Multiple Sclerosis. AJNR Am J Neuroradiol 37:1808-1815
Vos, Sjoerd B; Aksoy, Murat; Han, Zhaoying et al. (2016) Trade-off between angular and spatial resolutions in in vivo fiber tractography. Neuroimage 129:117-132

Showing the most recent 10 out of 446 publications