Conventional one-dimensional transducer modeling tools like the KLM model although commercially available cannot model the performance of arrays adequately. Commercial FEA software packages, ANSYS and PZFlex, have been combined with software for computing acoustic propagation such as CHIEF to simulate the performance of linear arrays. Although these results must still be verified carefully experimentally, they show that the input electrical impedance, pulse-echo waveform, cross-talk and radiation pattern can be simulated. This work will be extended to VHF arrays. The ultimate goal is to enable the virtual design of a transducer or array. This would not only shorten the time needed to complete a new design but also reduce the cost of prototyping the design. The experience of using the two FEA tools also lead to the realization that the performance of these tools in the near field of the array may not be satisfactory. Discrepancies in the results were found. Further studies on the causes of these discrepancies are warranted and will be pursued. ?

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR011795-03
Application #
6206560
Study Section
Project Start
1999-09-01
Project End
2000-08-31
Budget Start
1998-10-01
Budget End
1999-09-30
Support Year
3
Fiscal Year
1999
Total Cost
Indirect Cost
Name
Pennsylvania State University
Department
Type
DUNS #
City
University Park
State
PA
Country
United States
Zip Code
16802
Reddy, Anilkumar K; Hartley, Craig J; Pham, Thuy T et al. (2014) Young little mice express a premature cardiovascular aging phenotype. J Gerontol A Biol Sci Med Sci 69:152-9
Gurha, Priyatansh; Wang, Tiannan; Larimore, Ashley H et al. (2013) microRNA-22 promotes heart failure through coordinate suppression of PPAR/ERR-nuclear hormone receptor transcription. PLoS One 8:e75882
Crossland, Randy F; Durgan, David J; Lloyd, Eric E et al. (2013) A new rodent model for obstructive sleep apnea: effects on ATP-mediated dilations in cerebral arteries. Am J Physiol Regul Integr Comp Physiol 305:R334-42
Nagamani, Sandesh C S; Campeau, Philippe M; Shchelochkov, Oleg A et al. (2012) Nitric-oxide supplementation for treatment of long-term complications in argininosuccinic aciduria. Am J Hum Genet 90:836-46
Lee, Hyeong Jae; Zhang, Shujun (2012) Design of low-loss 1-3 piezoelectric composites for high-power transducer applications. IEEE Trans Ultrason Ferroelectr Freq Control 59:1969-75
Lloyd, Eric E; Crossland, Randy F; Phillips, Sharon C et al. (2011) Disruption of K(2P)6.1 produces vascular dysfunction and hypertension in mice. Hypertension 58:672-8
Hartley, Craig J; Reddy, Anilkumar K; Madala, Sridhar et al. (2011) Doppler velocity measurements from large and small arteries of mice. Am J Physiol Heart Circ Physiol 301:H269-78
Chintalgattu, Vishnu; Ai, Di; Langley, Robert R et al. (2010) Cardiomyocyte PDGFR-beta signaling is an essential component of the mouse cardiac response to load-induced stress. J Clin Invest 120:472-84
Song, Liang; Maslov, Konstantin; Shung, K Kirk et al. (2010) Ultrasound-array-based real-time photoacoustic microscopy of human pulsatile dynamics in vivo. J Biomed Opt 15:021303
Zhang, Shujun; Sherlock, Nevin P; Meyer, Richard J et al. (2009) Crystallographic dependence of loss in domain engineered relaxor-PT single crystals. Appl Phys Lett 94:162906

Showing the most recent 10 out of 24 publications