The Duke group has been developing 2-D arrays for 3D intra-cardiac ultrasound imaging for many years. The 2D arrays are currently fabricated from PZT-5H. The purpose of this program was to assess the advantages of applying single crystal PZN/PT to an existing Duke design for an intravascular 2D array. The extremely high piezoelectric properties and low acoustic impedance of PZN/PT in 33 mode operation should allow significant improvements in range resolution and grating lobe amplitude as each element should operate over a much broader bandwidth. The drawback is the difficulty in fabrication of a device with such a new material, where many of the properties are either unknown to date or vary form batch to batch. This project has been undertaken on two fronts. The fabrication issues have been examined simultaneous with the modeling. Because of the single crystal nature of PZN/PT, one dimensional models could only provide a rough estimate of the transducer performance. For a more accurate simulation, FEA modeling has to be used. To do so, materials properties of the single crystals must be known. These material properties are still lacking. Future work in modeling includes more materials properties measurements and verification of crystal alignment controlled resonance modes.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR011795-04
Application #
6348246
Study Section
Project Start
2000-09-01
Project End
2001-08-31
Budget Start
1998-10-01
Budget End
1999-09-30
Support Year
4
Fiscal Year
2000
Total Cost
$3,079
Indirect Cost
Name
Pennsylvania State University
Department
Type
DUNS #
City
University Park
State
PA
Country
United States
Zip Code
16802
Reddy, Anilkumar K; Hartley, Craig J; Pham, Thuy T et al. (2014) Young little mice express a premature cardiovascular aging phenotype. J Gerontol A Biol Sci Med Sci 69:152-9
Gurha, Priyatansh; Wang, Tiannan; Larimore, Ashley H et al. (2013) microRNA-22 promotes heart failure through coordinate suppression of PPAR/ERR-nuclear hormone receptor transcription. PLoS One 8:e75882
Crossland, Randy F; Durgan, David J; Lloyd, Eric E et al. (2013) A new rodent model for obstructive sleep apnea: effects on ATP-mediated dilations in cerebral arteries. Am J Physiol Regul Integr Comp Physiol 305:R334-42
Lee, Hyeong Jae; Zhang, Shujun (2012) Design of low-loss 1-3 piezoelectric composites for high-power transducer applications. IEEE Trans Ultrason Ferroelectr Freq Control 59:1969-75
Nagamani, Sandesh C S; Campeau, Philippe M; Shchelochkov, Oleg A et al. (2012) Nitric-oxide supplementation for treatment of long-term complications in argininosuccinic aciduria. Am J Hum Genet 90:836-46
Lloyd, Eric E; Crossland, Randy F; Phillips, Sharon C et al. (2011) Disruption of K(2P)6.1 produces vascular dysfunction and hypertension in mice. Hypertension 58:672-8
Hartley, Craig J; Reddy, Anilkumar K; Madala, Sridhar et al. (2011) Doppler velocity measurements from large and small arteries of mice. Am J Physiol Heart Circ Physiol 301:H269-78
Chintalgattu, Vishnu; Ai, Di; Langley, Robert R et al. (2010) Cardiomyocyte PDGFR-beta signaling is an essential component of the mouse cardiac response to load-induced stress. J Clin Invest 120:472-84
Song, Liang; Maslov, Konstantin; Shung, K Kirk et al. (2010) Ultrasound-array-based real-time photoacoustic microscopy of human pulsatile dynamics in vivo. J Biomed Opt 15:021303
Zhang, Shujun; Sherlock, Nevin P; Meyer, Richard J et al. (2009) Crystallographic dependence of loss in domain engineered relaxor-PT single crystals. Appl Phys Lett 94:162906

Showing the most recent 10 out of 24 publications