A significant problem in functional MRI (fMRI) studies is a satisfactory means of presenting visual stimuli within the confines of the MRI system, and presenting these stimuli stereoscopically and at high spatial resolution. A second difficulty is the need for monitoring of gaze direction in fMRI studies of the oculomotor system, in which accuracy of oculomotor responses is of great importance in interpretation of fMRI results. An additional difficulty in visual presentation is monitoring compliance with instructions as to gaze direction, which can be crucial to interpretation of fMRI results in studies of the visual system. In this project these problems are answered with the construction of a unique optical system compatible with the hardware of the UAB 4.1T MRI system. The system under construction includes a pair of high-resolution LCD screens (800x600) to be viewed by an integrated binocular optical system, which will include an adaptation of an existing computer-controlled ISCAN video-camera-based system for monitoring eye movements and gaze direction. Installation is scheduled for May 1998. Preliminary oculomotor fMRI results obtained prior to the installation of the optical system have been reported in Kidambi S et al., fMRI Detection of Frontal Eye Field Activation during Saccadic Eye Movements, Proc Intl Soc Magn Reson Med 1844, 1996. ? The optical system will be invaluable in oculomotor and vision-related fMRI studies and in many fMRI studies where non-verbal responses are required. It will also allow visual studies of stereopsis and depth perception. A system with this capability will thus find broad application in fMRI studies at many institutions. Development of this system will not only significantly enhance fMRI studies at the University of Alabama at Birmingham, but will also allow investigators at other institutions to be provided with the technology to significantly enhance their fMRI studies.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR011811-05
Application #
6480910
Study Section
Project Start
2001-08-01
Project End
2003-02-28
Budget Start
1997-10-01
Budget End
1998-09-30
Support Year
5
Fiscal Year
2001
Total Cost
$155,764
Indirect Cost
Name
University of Alabama Birmingham
Department
Type
DUNS #
004514360
City
Birmingham
State
AL
Country
United States
Zip Code
35294
Sirikul, Bovorn; Hunter, Gary R; Larson-Meyer, D Enette et al. (2007) Relationship between metabolic function and skeletal muscle fatigue during a 90 s maximal isometric contraction. Appl Physiol Nutr Metab 32:394-9
Redden, David T; Divers, Jasmin; Vaughan, Laura Kelly et al. (2006) Regional admixture mapping and structured association testing: conceptual unification and an extensible general linear model. PLoS Genet 2:e137
Elgavish, Rotem A; Twieg, Donald B (2003) Improved depiction of small anatomic structures in MR images using Gaussian-weighted spirals and zero-filled interpolation. Magn Reson Imaging 21:103-12
Twieg, Donald B (2003) Parsing local signal evolution directly from a single-shot MRI signal: a new approach for fMRI. Magn Reson Med 50:1043-52
Larson-Meyer, D Enette; Newcomer, Bradley R; Hunter, Gary R (2002) Influence of endurance running and recovery diet on intramyocellular lipid content in women: a 1H NMR study. Am J Physiol Endocrinol Metab 282:E95-E106
Newcomer, B R; Larson-Meyer, D E; Hunter, G R et al. (2001) Skeletal muscle metabolism in overweight and post-overweight women: an isometric exercise study using (31)P magnetic resonance spectroscopy. Int J Obes Relat Metab Disord 25:1309-15
Newman, S D; Twieg, D B; Carpenter, P A (2001) Baseline conditions and subtractive logic in neuroimaging. Hum Brain Mapp 14:228-35
Newman, S D; Twieg, D (2001) Differences in auditory processing of words and pseudowords: an fMRI study. Hum Brain Mapp 14:39-47
Patton, H K; Chu, W J; Hetherington, H P et al. (2001) Alkaline pH changes in the cerebellum of asymptomatic HIV-infected individuals. NMR Biomed 14:12-8
Larson-Meyer, D E; Newcomer, B R; Hunter, G R et al. (2001) Relation between in vivo and in vitro measurements of skeletal muscle oxidative metabolism. Muscle Nerve 24:1665-76

Showing the most recent 10 out of 19 publications