A novel technician has been developed which will image physiologic characteristics and toxic radicals in living tissues of animals and humans. This information has, heretofore, been unavailable. The technique has been slowly developing in a number of laboratories throughout the world despite widespread misconceptions about the possibility of obtaining good EPR signals at such low frequencies. However, recent advances in spectroscopic technique and spin probe development, as well as the understanding of the information that can be provided, poise this technique on the verge of breakthrough. The technique uses very low frequency electron paramagnetic resonance imaging, VLF-EPRI. Very low frequency (100 to 300 MHZ) is necessary to allow the electromagnetic energy, which stimulates resonant absorption, to penetrate deep into the tissue of animals. In many applications, the spectra are derived from a non-toxic spin probe, similar or identical to magnetic resonance imaging contrast material, which is infused into animal tissues. The spin probe, similar or identical to magnetic resonance imaging contrast material, which is infused into animal tissues. The spin probe can target various fluid compartment in tissues. Changes in the spectrum of the spin probe report local oxygen concentration with high accuracy. As a byproduct of the oxygen measurement, the spectrum can also report microviscosity, which may be important for cellular proliferation. Spin labeling of medicinal agents may allow in vivo images of their pharmacodynamics. These images deep in animal tissues have been recently reported with VLF-EPRI. Both signaling and toxic free radicals can be detected with VLF-EPRI in vivo. Nitric oxide and hydroxyl radical have been detected in animal tissues with VLF-EPRI. These early measurements have been relatively crude. However, there are clear paths to improvements in physiologic sensitivity and spatial resolution by orders of magnitude. We propose the development of center facilities with an array of VLF-EPRI spectroscopic imagers to achieve this improvement in sensitivity and resolution. It would exist within a major medical center. This would offer adjacent, coordinated animal care, access to MRI/Spiral CT scanning and advanced image correlation capability. The VLF-EPRI facilities would also coordinate with spin probe and spin trap synthesis investigators to improve the general technique and tailor it to the needs of an individual researcher. We envision the development of a unique center offering researchers the capability of generating new physiologic information from VLF-EPRI.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR012257-03
Application #
6394661
Study Section
Special Emphasis Panel (ZRG7-SSS-7 (69))
Program Officer
Levy, Abraham
Project Start
1999-09-30
Project End
2004-08-31
Budget Start
2001-09-01
Budget End
2002-08-31
Support Year
3
Fiscal Year
2001
Total Cost
$836,392
Indirect Cost
Name
University of Chicago
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
225410919
City
Chicago
State
IL
Country
United States
Zip Code
60637
Williams, Benjamin B; Pan, Xiaochuan; Halpern, Howard J (2005) EPR imaging: the relationship between CW spectra acquired from an extended sample subjected to fixed stepped gradients and the Radon transform of the resonance density. J Magn Reson 174:88-96
Mailer, Colin; Nielsen, Robert D; Robinson, Bruce H (2005) Explanation of spin-lattice relaxation rates of spin labels obtained with multifrequency saturation recovery EPR. J Phys Chem A 109:4049-61
Rosen, Gerald M; Beselman, Aleksandra; Tsai, Pei et al. (2004) Influence of conformation on the EPR spectrum of 5,5-dimethyl-1-hydroperoxy-1-pyrrolidinyloxyl: a spin trapped adduct of superoxide. J Org Chem 69:1321-30
Raines, Kimberly W; Cao, Guan-Liang; Porsuphatana, Supatra et al. (2004) Nitric oxide inhibition of ERK1/2 activity in cells expressing neuronal nitric-oxide synthase. J Biol Chem 279:3933-40
Kao, Joseph P Y; Rosen, Gerald M (2004) Esterase-assisted accumulation of 3-carboxy-2,2,5,5-tetramethyl-1-pyrrolidinyloxyl into lymphocytes. Org Biomol Chem 2:99-102
Dreher, Matthew R; Elas, Martyna; Ichikawa, Kazuhiro et al. (2004) Nitroxide conjugate of a thermally responsive elastin-like polypeptide for noninvasive thermometry. Med Phys 31:2755-62
Mailer, Colin; Robinson, Bruce H; Williams, Benjamin B et al. (2003) Spectral fitting: the extraction of crucial information from a spectrum and a spectral image. Magn Reson Med 49:1175-80
Porasuphatana, Supatra; Tsai, Pei; Rosen, Gerald M (2003) The generation of free radicals by nitric oxide synthase. Comp Biochem Physiol C Toxicol Pharmacol 134:281-9
Khan, Nadeem; Wilmot, Carmen M; Rosen, Gerald M et al. (2003) Spin traps: in vitro toxicity and stability of radical adducts. Free Radic Biol Med 34:1473-81
Plonka, Przemyslaw M; Wisniewska, Magdalena; Chlopicki, Stefan et al. (2003) X-band and S-band EPR detection of nitric oxide in murine endotoxaemia using spin trapping by ferro-di(N-(dithiocarboxy)sarcosine). Acta Biochim Pol 50:799-806

Showing the most recent 10 out of 33 publications