This subproject is one of many research subprojects utilizing theresources provided by a Center grant funded by NIH/NCRR. The subproject andinvestigator (PI) may have received primary funding from another NIH source,and thus could be represented in other CRISP entries. The institution listed isfor the Center, which is not necessarily the institution for the investigator.All ACERT c.w. spectrometers currently utilize conventional ca 100KHz magnetic field modulation for ESR spectral line detection. However, for high-field detection of moderately broad spectral linewidths the utility of this detection technique is severely constrained. Detection of moderately broad HF spectra corresponding to, e.g., spin-labeled proteins in the intermediate slow-motion regime, becomes relatively inefficient when Bmod << Hpp, necessitating operation of field modulation components at the extreme limit of power input capability, corresponding to a maximum field modulation of only 5 - 10Gpp. At field values exceeding this modulation level, coil-induced Lorentz forces become an increasingly significant microphonic noise source, and the coil power dissipation rapidly becomes a significantly perturbing heat source. Ideally, modulation widths of ca 100G would be available for a majority of HF samples, in particular biological samples at low concentrations,; however, this value is clearly out of reach of conventional direct magnetic field modulation techniques.An alternative modulation solution we have previously investigated is the circular-dichroism scheme described in the 2006 ACERT grant renewal proposal, Core Project III, at (F). For spectra that are not too broad, however, source frequency modulation (FM), a simpler and more easily implemented method of broad ESR line detection, seems possible (Hyde et al., 2007).Our initial task will be to evaluate the performance of a wide-band FM line detection system of at least 280 MHzpp (100Gpp) maximum modulation capability which may be adapted to our existing 170/240 GHz c.w. spectrometer. Because this HF spectrometer utilizes a bolometer power detector rather than a typical hetrodyne conversion and detection scheme as described elsewhere in the literature, our FM line detection system will differ in key design aspects with respect to FM systems described elsewhere. We believe, for example, that it is likely FM detection SNR in a bolometer (or other baseband power detection) system can be greatly enhanced by subtracting out the frequency- (i.e., field-) dependent baseline prior to synchronous demodulation. We have assigned this project a very high priority since improved HF c.w. ESR sensitivity is a critical factor in reading biological samples of low concentration.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR016292-08
Application #
7723964
Study Section
Special Emphasis Panel (ZRG1-BCMB-K (40))
Project Start
2008-09-01
Project End
2009-08-31
Budget Start
2008-09-01
Budget End
2009-08-31
Support Year
8
Fiscal Year
2008
Total Cost
$2,595
Indirect Cost
Name
Cornell University
Department
Chemistry
Type
Schools of Arts and Sciences
DUNS #
872612445
City
Ithaca
State
NY
Country
United States
Zip Code
14850
Jain, Rinku; Vanamee, Eva S; Dzikovski, Boris G et al. (2014) An iron-sulfur cluster in the polymerase domain of yeast DNA polymerase ?. J Mol Biol 426:301-8
Pratt, Ashley J; Shin, David S; Merz, Gregory E et al. (2014) Aggregation propensities of superoxide dismutase G93 hotspot mutants mirror ALS clinical phenotypes. Proc Natl Acad Sci U S A 111:E4568-76
Georgieva, Elka R; Borbat, Peter P; Ginter, Christopher et al. (2013) Conformational ensemble of the sodium-coupled aspartate transporter. Nat Struct Mol Biol 20:215-21
Airola, Michael V; Sukomon, Nattakan; Samanta, Dipanjan et al. (2013) HAMP domain conformers that propagate opposite signals in bacterial chemoreceptors. PLoS Biol 11:e1001479
Airola, Michael V; Huh, Doowon; Sukomon, Nattakan et al. (2013) Architecture of the soluble receptor Aer2 indicates an in-line mechanism for PAS and HAMP domain signaling. J Mol Biol 425:886-901
Gaffney, Betty J; Bradshaw, Miles D; Frausto, Stephen D et al. (2012) Locating a lipid at the portal to the lipoxygenase active site. Biophys J 103:2134-44
Dzikovski, Boris; Tipikin, Dmitriy; Freed, Jack (2012) Conformational distributions and hydrogen bonding in gel and frozen lipid bilayers: a high frequency spin-label ESR study. J Phys Chem B 116:6694-706
Maeda, Kiminori; Lodge, Matthew T J; Harmer, Jeffrey et al. (2012) Electron tunneling in lithium-ammonia solutions probed by frequency-dependent electron spin relaxation studies. J Am Chem Soc 134:9209-18
Georgieva, Elka R; Roy, Aritro S; Grigoryants, Vladimir M et al. (2012) Effect of freezing conditions on distances and their distributions derived from Double Electron Electron Resonance (DEER): a study of doubly-spin-labeled T4 lysozyme. J Magn Reson 216:69-77
Yang, Zhongyu; Liu, Yangping; Borbat, Peter et al. (2012) Pulsed ESR dipolar spectroscopy for distance measurements in immobilized spin labeled proteins in liquid solution. J Am Chem Soc 134:9950-2

Showing the most recent 10 out of 72 publications