This proposal is concerned with certain design variables affecting bone remodeling following primary cementless total hip arthroplasty. The use of cementless techniques in total hip arthroplasty heightens concern with stress-induced bone remodeling, fixation, and long term biocompatibility. Proximal cortical resorption of varying severity has been reported with a variety of cementless femoral stems, made from CoCr or from Ti6Al4V. Cortical resorption can lead to failure of the host bone, failure of the prosthetic device, and presents enormous problems for further reconstruction. The purpose of this proposal is to gain a better understanding of the relationship between stress-induced bony changes in the proximal femur following cementless total hip arthroplasty (THA) and implant design. We propose to investigate this relationship by studying bone remodeling as a function of cross-sectional stiffness related to stem modulus and stem geometry. Two hypotheses will be tested. (1) The elastic modulus and geometry of the femoral stem can be modulated to minimize long-term femoral remodeling changes. (2) The relationship between prosthetic-induced changes in the femur's mechanical environment and adaptive changes in cortical morphology is non-linear. Specifically, we plan to evaluate the effect of large variations in stem (i) elastic modulus and (ii) geometry (in this study, the location of the implant's centroids and bending axes relative to those of the femur) on changes in bone morphology in a canine model, while accounting for individual variation in the position of the stem within the femoral canal. These data will be used to determine if the relationship between the prosthesis-induced changes in femoral stress/strain and the changes in bone morphology is linear or non-linear. Thus, two key clinical questions are (i) how does bone remodeling vary over the range of relative stem stiffness of potential clinical feasibility and (ii) does stem geometry influence proximal bone loss following cementless THA? To address these issues, a canine primary THA model will be used in which stem stiffness will be varied over a 10-fold range. In a separate experiment, stem shape will be varied. The experimental endpoints will be the structural responses to the treatments (e.g., change in cortical area, thickness and porosity and medullary bone density). The data will be analyzed to test for the effects of the design variables on the remodeling response and to determine mechanistically how the prosthesis-induced changes in the mechanical environment of the femur correspond to the bony adaptive response. The goal of these experiments is to derive principles which will have clinical implications.

Agency
National Institute of Health (NIH)
Institute
National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS)
Type
Research Project (R01)
Project #
5R01AR016485-21
Application #
2078336
Study Section
Orthopedics and Musculoskeletal Study Section (ORTH)
Project Start
1979-05-01
Project End
1996-03-31
Budget Start
1994-04-01
Budget End
1995-03-31
Support Year
21
Fiscal Year
1994
Total Cost
Indirect Cost
Name
Rush University Medical Center
Department
Type
DUNS #
City
Chicago
State
IL
Country
United States
Zip Code
60612
Minihane, Keith P; Turner, Thomas M; Urban, Robert M et al. (2005) Effect of hip hemiarthroplasty on articular cartilage and bone in a canine model. Clin Orthop Relat Res :157-63
Qureshi, Abid A; Virdi, Amarjit S; Didonna, Michael L et al. (2002) Implant design affects markers of bone resorption and formation in total hip replacement. J Bone Miner Res 17:800-7
Onsten, I; Berzins, A; Shott, S et al. (2001) Accuracy and precision of radiostereometric analysis in the measurement of THR femoral component translations: human and canine in vitro models. J Orthop Res 19:1162-7
Weinans, H; Sumner, D R; Igloria, R et al. (2000) Sensitivity of periprosthetic stress-shielding to load and the bone density-modulus relationship in subject-specific finite element models. J Biomech 33:809-17
Sumner, D R; Turner, T M; Igloria, R et al. (1998) Functional adaptation and ingrowth of bone vary as a function of hip implant stiffness. J Biomech 31:909-17
Turner, T M; Sumner, D R; Urban, R M et al. (1997) Maintenance of proximal cortical bone with use of a less stiff femoral component in hemiarthroplasty of the hip without cement. An investigation in a canine model at six months and two years. J Bone Joint Surg Am 79:1381-90
Weinans, H; Sumner, D R (1997) Finite Element analyses to study periprosthetic bone adaptation. Stud Health Technol Inform 40:3-16
Smith, A M; Turner, T M; Sumner, D R (1996) Unilateral hip replacement causes bilateral changes in tibial bone mineral content in a canine model. J Bone Miner Res 11:693-6
Bryan, J M; Sumner, D R; Hurwitz, D E et al. (1996) Altered load history affects periprosthetic bone loss following cementless total hip arthroplasty. J Orthop Res 14:762-8
Sumner, D R; Turner, T M; Purchio, A F et al. (1995) Enhancement of bone ingrowth by transforming growth factor-beta. J Bone Joint Surg Am 77:1135-47

Showing the most recent 10 out of 23 publications