Total hip replacement (THR) surgery is the standard of care for advanced degenerative joint disease in the US. In 2002, an estimated 243,000 Americans benefited from this procedure. However, 18% of all THR surgeries are revisions, which have poorer outcomes and greater economic burden than primary THRs. Loosening of hip implants, due to osteolysis and tissue reactions to polyethylene wear debris, is considered to be the main problem limiting implant longevity in the US. Within the past decade, polyethylene materials used for THR have undergone major changes in sterilization and formulation, so that a range of sterilization and radiation crosslinking processes are now applied to polyethylene used in clinical practice. However, it remains unclear to what extent these processes affect the tendency of polyethylene bearing components to oxidatively degrade during long-term implantation in the body. It is further unknown to what extent oxidation of polyethylene in the body impacts the clinical performance of contemporary hip replacements. In this five-year competing continuation, we propose to extend our study of traceable gamma-air sterilized polyethylene hip bearing components to encompass retrieved gamma-inert sterilized and highly crosslinked polyethylene bearings for hip arthroplasty. Knowing that gamma air-sterilized polyethylene hip bearing components undergo in vivo oxidative degradation with significant reduction of ultimate strength, the following three new hypotheses are proposed: (1) contemporary gamma inert sterilized polyethylene hip bearings will undergo {region-specific} degradation of mechanical properties during in vivo use; (2) annealed highly crosslinked, polyethylene hip bearings that contain residual free radicals will undergo {region-specific} degradation of mechanical properties in vivo and remelted highly crosslinked polyethylene hip bearings, that are processed to quench free radicals, will not degrade significantly in vivo; and (3) wear and loosening as reasons for revision of highly crosslinked liners will be lower in prevalence than in gamma inert sterilized liners. ? ?

Agency
National Institute of Health (NIH)
Institute
National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS)
Type
Research Project (R01)
Project #
5R01AR047904-07
Application #
7434553
Study Section
Special Emphasis Panel (ZRG1-MOSS-A (04))
Program Officer
Panagis, James S
Project Start
2001-08-07
Project End
2010-06-30
Budget Start
2008-07-01
Budget End
2009-06-30
Support Year
7
Fiscal Year
2008
Total Cost
$469,659
Indirect Cost
Name
Drexel University
Department
Type
Schools of Engineering
DUNS #
002604817
City
Philadelphia
State
PA
Country
United States
Zip Code
19104
Arnholt, Christina M; MacDonald, Daniel W; Klein, Gregg R et al. (2018) What Is the Incidence of Cobalt-Chromium Damage Modes on the Bearing Surface of Contemporary Femoral Component Designs for Total Knee Arthroplasty? J Arthroplasty 33:3313-3319
Arnholt, Christina M; MacDonald, Daniel W; Underwood, Richard J et al. (2017) Do Stem Taper Microgrooves Influence Taper Corrosion in Total Hip Arthroplasty? A Matched Cohort Retrieval Study. J Arthroplasty 32:1363-1373
Urish, Kenneth L; Hamlin, Brian R; Plakseychuk, Anton Y et al. (2017) Trunnion Failure of the Recalled Low Friction Ion Treatment Cobalt Chromium Alloy Femoral Head. J Arthroplasty 32:2857-2863
Arnholt, Christina M; MacDonald, Daniel W; Malkani, Arthur L et al. (2016) Corrosion Damage and Wear Mechanisms in Long-Term Retrieved CoCr Femoral Components for Total Knee Arthroplasty. J Arthroplasty 31:2900-2906
Kocagoz, Sevi B; Underwood, Richard J; MacDonald, Daniel W et al. (2016) Ceramic Heads Decrease Metal Release Caused by Head-taper Fretting and Corrosion. Clin Orthop Relat Res 474:985-94
Agne, Matthias T; Underwood, Richard J; Kocagoz, Sevi B et al. (2015) Is there material loss at the backside taper in modular CoCr acetabular liners? Clin Orthop Relat Res 473:275-85
Fredette, Eliza K; MacDonald, Daniel W; Underwood, Richard J et al. (2015) Does Metal Transfer Differ on Retrieved Ceramic and CoCr Femoral Heads? Biomed Res Int 2015:283038
Hanzlik, Josa A; Day, Judd S; Rimnac, Clare M et al. (2015) Is There A Difference in Bone Ingrowth in Modular Versus Monoblock Porous Tantalum Tibial Trays? J Arthroplasty 30:1073-8
Kurtz, Steven M; MacDonald, Daniel W; Mont, Michael A et al. (2015) Retrieval analysis of sequentially annealed highly crosslinked polyethylene used in total hip arthroplasty. Clin Orthop Relat Res 473:962-71
Gilbert, Jeremy L; Sivan, Shiril; Liu, Yangping et al. (2015) Direct in vivo inflammatory cell-induced corrosion of CoCrMo alloy orthopedic implant surfaces. J Biomed Mater Res A 103:211-23

Showing the most recent 10 out of 48 publications