Vertebral fractures are the most common type of osteoporotic fracture, afflicting approximately one in three women and one in six men over the age of 50. Despite their high prevalence, sensitive and specific estimates of vertebral fracture risk have remained elusive. This is due in large part to the limited accuracy and precision of current methods of estimating vertebral strength. Average measures of bone mineral density (BMD) explain only 50-70% of the variance in vertebral strength, a result that is not surprising given the heterogeneous distribution of bone tissue throughout the vertebra. A growing and compelling amount of evidence points to importance of this heterogeneity in governing the mechanical behavior of the vertebra. Recent advances in quantitative computed tomography (QCT) allow non-invasive measurement of the distribution of bone density and even trabecular anisotropy in whole bones. We propose that these additional measurements can be used to establish a new standard for clinical evaluation of vertebral fracture risk. Our overall hypothesis is that CT- based methods that account for the heterogeneous distribution of density and trabecular anisotropy throughout the vertebra provide more accurate predictions of vertebral strength than do methods based solely on average BMD.
Four specific aims are proposed.
Aim #1 will test whether CT-based measures of the intra-vertebral heterogeneity in density are independent predictors of vertebral strength.
Aims #2 -#4 are closely coupled experimental and computational studies that will test the importance of incorporating specimen-specific, anisotropic material properties in QCT-based finite element (FE) models of the vertebra. These studies will investigate the effect of this material property assignment on the accuracy of the FE predictions of vertebral strength and failure behavior.
Aim #2 will use micro-finite element analysis to quantify the anisotropic elastic properties throughout the centrum.
Aim #3 will carry out the QCT-based FE analyses using the material properties obtained in Aim #2 and also using properties determined purely from estimates based on BMD or on BMD and trabecular anisotropy. The accuracy of the FE predictions of vertebral mechanical behavior will be evaluated through experiments performed in Aim #4. These experiments will use 3-D failure visualization techniques that we have developed over the past several years. These techniques afford us the unique ability to assess the fidelity with which the FE models predict bone strength as well as the true deformation and failure behavior of the vertebra. Such assessment is critical for gauging the performance of these models, for identifying means of improving their predictions, and for enabling their widespread implementation in the clinical arena. Taken together, the proposed studies constitute a set of concrete and consequential steps towards our long-term goal of developing techniques for highly accurate, patient-specific predictions of vertebral strength from clinically feasible measurements. As such, this work has strong potential for leading the way to better diagnosis, treatment, and prevention of spine fractures.

Public Health Relevance

. One in three women and one in six men over age 50 will suffer a spine fracture in their remaining lifetime. This project focuses on developing methods for obtaining more accurate predictions of bone strength in the spine.

Agency
National Institute of Health (NIH)
Institute
National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS)
Type
Research Project (R01)
Project #
5R01AR054620-02
Application #
7652325
Study Section
Skeletal Biology Structure and Regeneration Study Section (SBSR)
Program Officer
Lester, Gayle E
Project Start
2008-07-07
Project End
2013-04-30
Budget Start
2009-05-01
Budget End
2010-04-30
Support Year
2
Fiscal Year
2009
Total Cost
$321,660
Indirect Cost
Name
Boston University
Department
Engineering (All Types)
Type
Schools of Engineering
DUNS #
049435266
City
Boston
State
MA
Country
United States
Zip Code
02215
Morgan, Elise F; Unnikrisnan, Ginu U; Hussein, Amira I (2018) Bone Mechanical Properties in Healthy and Diseased States. Annu Rev Biomed Eng 20:119-143
Hussein, Amira I; Louzeiro, Daniel T; Unnikrishnan, Ginu U et al. (2018) Differences in Trabecular Microarchitecture and Simplified Boundary Conditions Limit the Accuracy of Quantitative Computed Tomography-Based Finite Element Models of Vertebral Failure. J Biomech Eng 140:
Kaiser, Jarred; Allaire, Brett; Fein, Paul M et al. (2018) Correspondence between bone mineral density and intervertebral disc degeneration across age and sex. Arch Osteoporos 13:123
Fein, Paul M; DelMonaco, Alexander; Jackman, Timothy M et al. (2017) Is bone density associated with intervertebral disc pressure in healthy and degenerated discs? J Biomech 64:41-48
Osterhoff, Georg; Morgan, Elise F; Shefelbine, Sandra J et al. (2016) Bone mechanical properties and changes with osteoporosis. Injury 47 Suppl 2:S11-20
Jackman, Timothy M; Hussein, Amira I; Curtiss, Cameron et al. (2016) Quantitative, 3D Visualization of the Initiation and Progression of Vertebral Fractures Under Compression and Anterior Flexion. J Bone Miner Res 31:777-88
Jackman, Timothy M; DelMonaco, Alex M; Morgan, Elise F (2016) Accuracy of finite element analyses of CT scans in predictions of vertebral failure patterns under axial compression and anterior flexion. J Biomech 49:267-75
Unnikrishnan, Ginu U; Gallagher, John A; Hussein, Amira I et al. (2015) Elastic Anisotropy of Trabecular Bone in the Elderly Human Vertebra. J Biomech Eng 137:114503
Jackman, Timothy M; Hussein, Amira I; Adams, Alexander M et al. (2014) Endplate deflection is a defining feature of vertebral fracture and is associated with properties of the underlying trabecular bone. J Orthop Res 32:880-6
Hussein, Amira I; Mason, Zachary D; Morgan, Elise F (2013) Presence of intervertebral discs alters observed stiffness and failure mechanisms in the vertebra. J Biomech 46:1683-8

Showing the most recent 10 out of 18 publications