application) The long term goal of this research is to develop methods and instrumentation to obtain improved quantification of the radioisotope distribution in humans and animals. SPRINT II is a third generation SPECT instrument developed as part of this ongoing effort. The focus of this proposal is to define and validate methods of data acquisition, correction, and analysis of SPECT data which will facilitate clinical and experimental use of this instrument and exploit some of its unique features. The applicants will investigate two innovative data acquisition strategies with SPRINT II, which should measurably increase data accuracy and improve signal-to-noise ratios: 1) determine the value of acquiring a vertex view of the brain during a conventional SPECT acquisition and incorporating this information into the image reconstruction or parameter estimation process; 2) determine the optimal aperture resolution to best estimate myocardial rate constants for freely diffusible tracers such as SQ30217. The analysis will include noninvasive determination of the input function, the effects of gating, and temporal variation of the slit width. The applicants will also develop and evaluate methods to measure and correct for scatter, attenuation, and patient motion and make hardware improvements to SPRINT II for the purpose of improving both spatial and energy resolution.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
2R01CA032846-21
Application #
3170692
Study Section
Diagnostic Radiology Study Section (RNM)
Project Start
1983-04-01
Project End
1994-02-28
Budget Start
1991-03-01
Budget End
1992-02-29
Support Year
21
Fiscal Year
1991
Total Cost
Indirect Cost
Name
University of Michigan Ann Arbor
Department
Type
Schools of Medicine
DUNS #
791277940
City
Ann Arbor
State
MI
Country
United States
Zip Code
48109
Ficaro, E P; Fessler, J A; Ackermann, R J et al. (1995) Simultaneous transmission-emission thallium-201 cardiac SPECT: effect of attenuation correction on myocardial tracer distribution. J Nucl Med 36:921-31
Ficaro, E P; Fessler, J A; Rogers, W L et al. (1994) Comparison of americium-241 and technetium-99m as transmission sources for attenuation correction of thallium-201 SPECT imaging of the heart. J Nucl Med 35:652-63
Koral, K F; Wang, X; Zasadny, K R et al. (1991) Testing of local gamma-ray scatter fractions determined by spectral fitting. Phys Med Biol 36:177-90
O'Tuama, L A; Phillips, P C; Smith, Q R et al. (1991) L-methionine uptake by human cerebral cortex: maturation from infancy to old age. J Nucl Med 32:16-22
O'Tuama, L A; Phillips, P C; Strauss, L C et al. (1990) Two-phase [11C]L-methionine PET in childhood brain tumors. Pediatr Neurol 6:163-70
Stewart, R E; Schwaiger, M; Hutchins, G D et al. (1990) Myocardial clearance kinetics of technetium-99m-SQ30217: a marker of regional myocardial blood flow. J Nucl Med 31:1183-90