Since their initial conception approximately fourteen years ago, active-matrix flat-panel imagers (AMFPIs) have undergone extensive research and development. Our prior NIH-sponsored research efforts (for which this is a competing renewal), along with the efforts of others, have directly contributed toward the recent commercial introduction of the technology to external beam, radiotherapy portal imaging in clinical environments. AMFPIs represent a highly compact, large area (presently up to 40x40 cm2), solid-state technology that can be operated both radiographically and fluoroscopically. They offer substantially improved image quality at radiotherapy energies compared to that of the previous """"""""gold standard,"""""""" film (which itself provides image quality superior to that of other electronic portal imaging technologies). However, AMFPIs, like all commercially available portal imaging technologies, make use of only -1 percent of the incident radiation. The result is that the frequency-dependent detective quantum efficiency (DQE - a widely accepted observer-independent measure of imager performance) of AMFPIs, although higher than that of other commercial portal imaging technologies, is still only 1 percent. Thus, even though current AMFPIs provide radiotherapy images with a fairly high degree of spatial and contrast information content, significant improvements in image quality and DQE are possible, allowing improved clinical utility and new uses. Consequently, the hypothesis to be examined in the proposed research is: """"""""Through the incorporation of innovative strategies, the DQE of radiotherapy AMFPIs can be substantially increased through more efficient use of the incident radiation."""""""" Three approaches for increasing DQE will be examined, all of which offer the potential of increasing the percentage of the beam interacting with the imager while minimizing degradation of spatial resolution. Two approaches involve indirect detection of the incident radiation (using segmented scintillating converters employing CsI(Tl) and GcI2O2S:Th) while a third approach involves direct detection of the radiation (using relatively thick layers of HgI2 photoconductive material). This three-year project, if successful, would identify the most promising strategy to substantially increase the DQE, potentially in excess of a factor of 10, and conceivably leading to significant improvements in image quality, even at very low doses.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
5R01CA051397-09
Application #
6622073
Study Section
Diagnostic Imaging Study Section (DMG)
Program Officer
Stone, Helen B
Project Start
1990-02-01
Project End
2005-02-28
Budget Start
2003-03-01
Budget End
2004-02-29
Support Year
9
Fiscal Year
2003
Total Cost
$703,473
Indirect Cost
Name
University of Michigan Ann Arbor
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
073133571
City
Ann Arbor
State
MI
Country
United States
Zip Code
48109
El-Mohri, Youcef; Antonuk, Larry E; Choroszucha, Richard B et al. (2014) Optimization of the performance of segmented scintillators for radiotherapy imaging through novel binning techniques. Phys Med Biol 59:797-818
Liu, Langechuan; Antonuk, Larry E; El-Mohri, Youcef et al. (2014) Optimization of the design of thick, segmented scintillators for megavoltage cone-beam CT using a novel, hybrid modeling technique. Med Phys 41:061916
Jiang, Hao; Zhao, Qihua; Antonuk, Larry E et al. (2013) Development of active matrix flat panel imagers incorporating thin layers of polycrystalline HgI(2) for mammographic x-ray imaging. Phys Med Biol 58:703-14
Liu, Langechuan; Antonuk, Larry E; Zhao, Qihua et al. (2012) Countering beam divergence effects with focused segmented scintillators for high DQE megavoltage active matrix imagers. Phys Med Biol 57:5343-58
El-Mohri, Youcef; Antonuk, Larry E; Zhao, Qihua et al. (2011) Low-dose megavoltage cone-beam CT imaging using thick, segmented scintillators. Phys Med Biol 56:1509-27
Zhao, Qihua; Antonuk, Larry E; El-Mohri, Youcef et al. (2010) Performance evaluation of polycrystalline HgI2 photoconductors for radiation therapy imaging. Med Phys 37:2738-48
Wang, Yi; El-Mohri, Youcef; Antonuk, Larry E et al. (2010) Monte Carlo investigations of the effect of beam divergence on thick, segmented crystalline scintillators for radiotherapy imaging. Phys Med Biol 55:3659-73
Wang, Yi; Antonuk, Larry E; Zhao, Qihua et al. (2009) High-DQE EPIDs based on thick, segmented BGO and CsI:Tl scintillators: performance evaluation at extremely low dose. Med Phys 36:5707-18
Wang, Yi; Antonuk, Larry E; El-Mohri, Youcef et al. (2009) A Monte Carlo investigation of Swank noise for thick, segmented, crystalline scintillators for radiotherapy imaging. Med Phys 36:3227-38
Wang, Yi; Antonuk, Larry E; El-Mohri, Youcef et al. (2008) Monte Carlo investigations of megavoltage cone-beam CT using thick, segmented scintillating detectors for soft tissue visualization. Med Phys 35:145-58

Showing the most recent 10 out of 23 publications