This program is a continuation of a collaborative research effort between investigators at the Massachusetts Institute of Technology and the Massachusetts Eye and Ear Infirmary. Our program is multidisciplinary and combines state of the art laser and optical measurement technology with biomedical and medical research. Our objective is twofold: To explore new techniques to selectively enhance desired therapeutic laser tissue effects and to develop diagnostics of laser tissue interaction and microstructure in biological systems.
The specific aims of this program are to: 1) Investigate ultrashort pulse laser induced optical breakdown as an approach for performing highly localized surgical incisions of intraocular structures using newly developed variable pulse duration and variable high repetition rate laser technology. Our investigation will include studies of fundamental physical incision and collateral damage using clinically relevant biological models in vitro. Applications to intraocular surgery will be explored using a vitreal membrane model and retinal injury studies in vivo. The basic premise of the ultrashort pulse scalpel is to use pulse duration to control collateral damage and multiple high repetition rate exposure to accumulate the desired effects of tissue incision. The development of an intraocular laser treatment capable of highly localized incisions with minimal collateral damage would have applications for a wide range of vitreal retinal conditions. 2) Develop optical ranging using coherence interferometry as a diagnostic for use either independently or in conjunction with intraocular laser surgery. This optical ranging technique is noncontacting, uses a compact laser diode source, requires low incident power levels (10 mu W) and provides a spatial resolution of 10 mum with sensitivity to reflected signals of 1 part in 1010. A clinically viable optical ranging device using fiber optic technology will be developed. Extensions of this technique such as scanning or using multiple wavelengths to distinguish differences in histological structure will be explored. Finally, optical ranging will be applied for measurements of retinal thickness and evaluated as a diagnostic for glaucoma using an animal model. The development of a noncontact method with superior resolution to ultrasound would permit real time monitoring of intraocular laser surgery and would have numerous medical diagnostic applications. 3) Finally as an extension of concepts demonstrated in our ultrashort pulse studies, we will perform pilot studies to explore methods for achieving highly localized thermal effects using multiple pulse exposure techniques with high power solid state IR lasers and dye enhanced absorption in a retinal vessel model.

Agency
National Institute of Health (NIH)
Institute
National Eye Institute (NEI)
Type
Research Project (R01)
Project #
5R01EY011289-14
Application #
2888493
Study Section
Special Emphasis Panel (ZRG7-SSS-1 (08))
Project Start
1985-09-01
Project End
2000-05-31
Budget Start
1999-06-01
Budget End
2000-05-31
Support Year
14
Fiscal Year
1999
Total Cost
Indirect Cost
Name
Massachusetts Institute of Technology
Department
Type
Organized Research Units
DUNS #
City
Cambridge
State
MA
Country
United States
Zip Code
02139
Arya, Malvika; Rashad, Ramy; Sorour, Osama et al. (2018) Optical coherence tomography angiography (OCTA) flow speed mapping technology for retinal diseases. Expert Rev Med Devices :1-8
Schirrmacher, Franziska; Köhler, Thomas; Endres, Jürgen et al. (2018) Temporal and volumetric denoising via quantile sparse image prior. Med Image Anal 48:131-146
Liang, Kaicheng; Wang, Zhao; Ahsen, Osman O et al. (2018) Cycloid scanning for wide field optical coherence tomography endomicroscopy and angiography in vivo. Optica 5:36-43
Wang, Bo; Lucy, Katie A; Schuman, Joel S et al. (2018) Tortuous Pore Path Through the Glaucomatous Lamina Cribrosa. Sci Rep 8:7281
Swanson, Eric A; Fujimoto, James G (2017) The ecosystem that powered the translation of OCT from fundamental research to clinical and commercial impact [Invited]. Biomed Opt Express 8:1638-1664
Ahsen, Osman O; Lee, Hsiang-Chieh; Liang, Kaicheng et al. (2017) Ultrahigh-speed endoscopic optical coherence tomography and angiography enables delineation of lateral margins of endoscopic mucosal resection: a case report. Therap Adv Gastroenterol 10:931-936
Wang, Bo; Lucy, Katie A; Schuman, Joel S et al. (2017) Location of the Central Retinal Vessel Trunk in the Laminar and Prelaminar Tissue of Healthy and Glaucomatous Eyes. Sci Rep 7:9930
Lu, Chen D; Lee, ByungKun; Schottenhamml, Julia et al. (2017) Photoreceptor Layer Thickness Changes During Dark Adaptation Observed With Ultrahigh-Resolution Optical Coherence Tomography. Invest Ophthalmol Vis Sci 58:4632-4643
Lee, Hsiang-Chieh; Ahsen, Osman O; Liang, Kaicheng et al. (2017) Endoscopic optical coherence tomography angiography microvascular features associated with dysplasia in Barrett's esophagus (with video). Gastrointest Endosc 86:476-484.e3
Rebhun, Carl B; Moult, Eric M; Novais, Eduardo A et al. (2017) Polypoidal Choroidal Vasculopathy on Swept-Source Optical Coherence Tomography Angiography with Variable Interscan Time Analysis. Transl Vis Sci Technol 6:4

Showing the most recent 10 out of 300 publications