Agency
National Institute of Health (NIH)
Institute
National Institute of General Medical Sciences (NIGMS)
Type
Research Project (R01)
Project #
1R01GM054585-01
Application #
2193935
Study Section
Metallobiochemistry Study Section (BMT)
Project Start
1996-08-01
Project End
1999-07-31
Budget Start
1996-08-01
Budget End
1997-07-31
Support Year
1
Fiscal Year
1996
Total Cost
Indirect Cost
Name
University of Minnesota Twin Cities
Department
Chemistry
Type
Other Domestic Higher Education
DUNS #
168559177
City
Minneapolis
State
MN
Country
United States
Zip Code
55455
Haidar Ahmad, Imad A; Soliven, Arianne; Allen, Robert C et al. (2015) Comparison of core-shell particles and sub-2?m fully porous particles for use as ultrafast second dimension columns in two-dimensional liquid chtomatography. J Chromatogr A 1386:31-8
Beyaza, Ayse; Fana, Wenzhe; Carr, Peter W et al. (2014) Instrument parameters controlling retention precision in gradient elution reversed-phase liquid. J Chromatogr A 1371:90-105
Potts, Lawrence W; Carr, Peter W (2013) Analysis of the temporal performance of one versus on-line comprehensive two-dimensional liquid chromatography. J Chromatogr A 1310:37-44
Haidar Ahmad, Imad A; Carr, Peter W (2013) Improved synthesis of carbon-clad silica stationary phases. Anal Chem 85:11765-70
Soliven, Arianne; Haidar Ahmad, Imad A; Filgueira, Marcelo R et al. (2013) Optimization of gradient reversed phase chromatographic peak capacity for low molecular weight solutes. J Chromatogr A 1273:57-65
Allen, Robert C; John, Mallory G; Rutan, Sarah C et al. (2012) Effect of background correction on peak detection and quantification in online comprehensive two-dimensional liquid chromatography using diode array detection. J Chromatogr A 1254:51-61
Filgueira, Marcelo R; Castells, Cecilia B; Carr, Peter W (2012) A simple, robust orthogonal background correction method for two-dimensional liquid chromatography. Anal Chem 84:6747-52
Allen, Robert C; Rutan, Sarah C (2012) Semi-automated alignment and quantification of peaks using parallel factor analysis for comprehensive two-dimensional liquid chromatography-diode array detector data sets. Anal Chim Acta 723:7-17
Zhang, Yu; Luo, Hao; Carr, Peter W (2012) Silica-based, hyper-crosslinked acid stable stationary phases for high performance liquid chromatography. J Chromatogr A 1228:110-24
Paek, Changyub; Huang, Yuan; Filgueira, Marcelo R et al. (2012) Development of a carbon clad core-shell silica for high speed two-dimensional liquid chromatography. J Chromatogr A 1229:129-39

Showing the most recent 10 out of 51 publications