The long-term objective of this research is to make pulsatile heart replacement systems available to smaller adult patients. This is a non-trivial matter, because reduction in the size of a pulsatile blood pump affects (1) the fluid dynamics of the pump, (2) the energetics of the pump and actuator, and (3) the stresses experienced by the blood contacting materials. Thus, we consider studies such as those described here to be critical to the availability of artificial hearts and pulsatile ventricular assist devices for the full spectrum of adult patients. We propose to study the underlying principles of pump size reduction through three specific aims: FIRST, we will compare in vitro measurements of the flow field with in vivo measures of thrombogenesis and hemolysis. Specifically, we will use Computational Fluid Dynamics to predict the flow field and Laser Doppler Anemometry and Particle Image Velocimetry to measure fluid velocity and shear rate with a high degree of spatial and temporal resolution, in pump chambers designed according to various scaling parameters. Classical dimensionless analysis will serve as guidance in scaling to achieve fluid dynamic similitude, and to generalize these measurements for predictive purposes. The significance of these findings will be assessed through in vivo studies in calves using completely implanted blood pumps, using the same pump chambers under similar fluid dynamic conditions. Thrombogenesis will be assessed through hematology studies and explant analysis. Platelet and fibrin adhesion will be quantified using post explant gross exam, histological examination and multi-scale surface analysis. Rapid manufacturing methods will be used to fabricate the variety of pumping chambers required for these experiments. SECONDLY, we will develop relationships governing energetic performance of the system, utilizing a computer simulation of the energy converter, blood pump, circulation, controller, and energy transmission system. We will thereby optimize the major subsystems to minimize power consumption. Results will be validated on a mock circulatory loop. THIRDLY, we will study the effects of reduced pump chamber size and pump shape parameters on biomaterial stresses using finite element analysis. Predicted strains will be validated using statically pressurized pump chambers. We expect that this research will be broadly applicable to pulsatile blood pump design, especially by improving our understanding of the relationships between fluid dynamics and thrombogenesis in a complex, time-varying flow field. This work requires a multi-disciplinary effort in surgery; engineering, fluid mechanics, and hematology, with the means to efficiency manufacture blood pump systems and carry out the necessary in vitro and in vivo studies.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project (R01)
Project #
5R01HL060276-06
Application #
6915669
Study Section
Special Emphasis Panel (ZRG1-SRB-G (03))
Program Officer
Baldwin, Tim
Project Start
1999-04-15
Project End
2007-05-31
Budget Start
2005-06-01
Budget End
2006-05-31
Support Year
6
Fiscal Year
2005
Total Cost
$637,305
Indirect Cost
Name
Pennsylvania State University
Department
Surgery
Type
Schools of Medicine
DUNS #
129348186
City
Hershey
State
PA
Country
United States
Zip Code
17033
Jhun, Choon-Sik; Stauffer, Megan A; Reibson, John D et al. (2018) Determination of Reynolds Shear Stress Level for Hemolysis. ASAIO J 64:63-69
Cooper, Timothy K (2015) Letter to the Editor regarding the article ""Left ventricular assist devices: a kidney's perspective"". Heart Fail Rev 20:751-2
Navitsky, Michael A; Taylor, Joshua O; Smith, Alexander B et al. (2014) Platelet adhesion to polyurethane urea under pulsatile flow conditions. Artif Organs 38:1046-53
Topper, Stephen R; Navitsky, Michael A; Medvitz, Richard B et al. (2014) The Use of Fluid Mechanics to Predict Regions of Microscopic Thrombus Formation in Pulsatile VADs. Cardiovasc Eng Technol 5:54-69
Navitsky, Michael A; Deutsch, Steven; Manning, Keefe B (2013) A thrombus susceptibility comparison of two pulsatile Penn State 50 cc left ventricular assist device designs. Ann Biomed Eng 41:4-16
Nanna, Jason C; Navitsky, Michael A; Topper, Stephen R et al. (2011) A fluid dynamics study in a 50?cc pulsatile ventricular assist device: influence of heart rate variability. J Biomech Eng 133:101002
Nanna, Jason C; Wivholm, Jennifer A; Deutsch, Steven et al. (2011) Flow field study comparing design iterations of a 50 cc left ventricular assist device. ASAIO J 57:349-57
Medvitz, Richard B; Reddy, Varun; Deutsch, Steve et al. (2009) Validation of a CFD methodology for positive displacement LVAD analysis using PIV data. J Biomech Eng 131:111009
Haut Donahue, T L; Dehlin, W; Gillespie, J et al. (2009) Finite element analysis of stresses developed in the blood sac of a left ventricular assist device. Med Eng Phys 31:454-60
Medvitz, Richard B; Kreider, James W; Manning, Keefe B et al. (2007) Development and validation of a computational fluid dynamics methodology for simulation of pulsatile left ventricular assist devices. ASAIO J 53:122-31

Showing the most recent 10 out of 21 publications