Superconducting magnets are required for MRI systems that can operate at elevated temperatures and with higher magnetic field without the expensive and in many places, unavailable liquid helium that is required with Low Temperature Superconductors (LTS), and for enabling NMR instruments to operate above the 23 T LTS field limit. High Temperature Superconductors (HTS) provide the best options for advancing the performance of these instruments at the lower-cost elevated temperatures of mechanical refrigeration provided they can be made with the required form, strength, uniformity and current density into persistent current coils. The Magnet Technology Division (MTD) of the MIT Francis Bitter Magnet Laboratory (FBML), our partner in this Phase I STTR Program, was first to recognize and propose to the NIH in 1999, that HTS-based conductors must be incorporated into MRI and NMR magnets in order to surpass these limits. Among HTS conductors, only 2212 wire can provide superior Je in much higher operating temperatures and magnetic fields while in principle enabling wire forms, for example, round and rectangular, that are proven to work with LTS. However, in order to meet this demand, 2212 coils must be developed with: 1) improved wire stress and bend tolerance in long lengths to allow for simpler coil fabrication and operation with large Lorentz forces, 2) capability for superconducting joints to allow much lower costs and more uniform fields via persistent current operation modes, and 3) high, uniform current densities in layer-wound configurations. Solid Material Solutions (SMS) is now developing coiled forms of strong, rectangular 2212 wire with focus in this program on a first-of-its-kind, persistent mode HTS coil that is made with strong 2212 wire and superconducting joints. Firstly, SMS, with its partner, the MTD at MIT-FBML, will develop a superconducting joint technique for its strong, rectangular, high current density 2212 wire. Joint configuration, melt texture parameters and wire / joint Ic?s will be investigated based on the results of a preliminary study that has already demonstrated that a superconducting joint can be produced between 2212 wire ends. Secondly, the technique will be applied to develop superconducting joints and a prototype persistent current switch. Joints will be prepared between reinforced wire ends and heat treatments completed, followed by Ic tests of joints as well as coiled wire sections. Using the best samples, a method for switching to persistent mode will be established with heaters, and with field-decay rates characterized to demonstrate that persistent current carrying joints can be achieved with coiled strong 2212 wire. Thirdly, a first persistent mode demonstration HTS coil will be designed, produced and tested, based on our strong 2212 wire and coil making know-how. This coil will be designed and built so that it can generate a central field of up to about 5 T at or below Ic, with loop-closing superconducting joints, and heater to allow switching to persistent mode. It will be tested at 4.2 K in driven current mode up to Ic and then with a background field for a total field of > 8 T. It will then be charged to different current levels, followed by switching to persistent mode. Tests will be completed to measure its field decay rates in background fields up to about 4 T, in order to characterize persistent mode properties and demonstrate our capability to produce and operate strong-wire based 2212 coils in persistent mode. When fully developed, this advance will enable the practical production of persistent mode HTS magnets based on our 2212 superconductor, for use in liquid He-free, and higher field MRI as well as >1GHz NMR systems.

Public Health Relevance

Superconducting magnets are required that enable MRI systems to operate at higher than 4.2 K without the expensive and in many places, unavailable liquid He (LHe), that is currently used with Low Temperature Superconductors (LTS), and for NMR instruments that operate at field levels above the 23T LTS limit. High Temperature Superconductors (HTS) provide the best options for advancing MRI systems to operating temperatures that are attained with LHE-free refrigeration, provided they can be made with the required from, strength, uniformity and current density (Je) into persistent current coils. Analysts forecast global NMR sales to grow by about 9% annually for the next 5 years, driven largely by the start of sales of >1 GHz systems that require HTS-based field-boosting magnets, and global MRI sales to grow above $6 B/yr in the same timeframe. Solid Material Solutions plans to develop and sell products into these markets. Among HTS conductors, only 2212 (Tc~80K) can provide superior Je in much higher operating temperatures and magnetic fields in wire forms, for example, round and rectangular, that are proven to work with LTS. Among round / rectangular wire candidates, MgB2, like Nb3Sn, also loses its ability to carry current at the high fields and temperatures possible with 2212, preventing its use at conditions accessible by 2212, despite the low cost of its constituents. In the next step, 2212 coils must be developed with: 1) improved wire stress and bend tolerance in long lengths, 2) capability for superconducting joints and persistent current operation modes, and 3) high, uniform current densities in layer-wound configurations. Solid Material Solutions (SMS) is developing coiled forms of its strong, rectangular 2212 wire with focus in this program on a first-of-its-kind, persistent mode HTS coil that is made with superconducting joints. As a first and most significant step, this program will prove the technology for making superconducting joints in high Je coils comprised of strong 2212 wires, so that following reaction, the coil, is capable of persistent mode operation. MRI application: Liquid He free MRI will be realized when HTS-based wires such as 2212 (not tapes) are fully developed that can operate at much higher temperatures than Nb3Sn or NbTi, for example above 20 K. However, the wire for this must be similar in robustness, form, quality and with persistent current joint capability, to NbTi and Nb3Sn. NMR application: Highest field NMR magnets generate about 23 T using a combination of LTS NbTi and Nb3Sn solenoids that are operated near their upper field limits, pushing all-LTS magnets as far as they can go to attain 1 GHz. However, it is widely agreed that both solution [1] and magic-angle-spinning (MAS) solid-state [2] NMR will benefit greatly from >1 GHz levels. Recent data on several proteins indicated that, for solution NMR, resolution is optimized in the range of 1.2?1.4GHz, whereas, for magic-angle spinning (MAS) solid-state NMR, optimal field is simply the highest field possible [2]. The Magnet Technology Division (MTD) of the MIT Francis Bitter Magnet Laboratory (FBML), our partner in this Phase I STTR Program, was first to propose to the NIH in 1999, that HTS-based conductors must be incorporated into NMR magnets in order to surpass 1 GHz [3]. Over the past year, SMS has advanced the status of its strong, long-length 2212 rectangular and round wire capability. As well, SMS has developed a capability to fabricate these wires into compact coils by wind and react, as is currently done with Nb3Sn for NMR, and into large diameter coils by react and wind for MRI as is done with NbTi. In the first part of this Phase 1 STTR program, SMS will develop a superconducting joint technique for its strong, rectangular, high Je 2212 wire. Joint configuration, melt texture parameters and wire / joint Je?s will be investigated based on the results of a preliminary study that has already demonstrated that a superconducting 2212 joint can be produced. In the second part, the technique will be applied to develop superconducting joints and a prototype persistent current switch in coiled 2212 wire. Joints will be prepared between reinforced wire ends followed by Ic tests of joints as well as coiled wire sections. Using the best samples, a method for switching to persistent mode will be established with heaters, and with field-decay rates characterized to demonstrate that persistent current carrying joints can be achieved. In the third part, a first persistent mode HTS coil will be designed, produced and tested, based on our strong 2212 wire and coil making know-how. This coil will be designed and built so that it can generate a central field of up to about 5 T at or below Ic, with loop-closing superconducting joints, and heater to allow switching to persistent mode. It will be tested at 4.2 K in driven current mode up to Ic and then with a background field for a total field of > 8 T. It will then be switched to persistent mode and tests completed to measure its field decay rates in background fields up to about 4 T, in order to demonstrate basic capability to produce and operate strong-wire based 2212 coils in persistent mode. When fully developed in a Phase 2 program, this advance will enable the practical production of persistent mode HTS magnets based on our 2212 superconductor, for use in liquid He-free, and higher field MRI as well as >1GHz NMR systems.

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Small Business Innovation Research Grants (SBIR) - Phase I (R43)
Project #
1R43EB025109-01
Application #
9409328
Study Section
Special Emphasis Panel (ZRG1)
Program Officer
Wang, Shumin
Project Start
2017-09-01
Project End
2018-08-31
Budget Start
2017-09-01
Budget End
2018-08-31
Support Year
1
Fiscal Year
2017
Total Cost
Indirect Cost
Name
Solid Material Solutions, LLC
Department
Type
DUNS #
020074970
City
North Chelmsford
State
MA
Country
United States
Zip Code
01863