Glaucoma is the leading cause of blindness in the world. Glaucoma is a complex disease with many underlying etiologies. Currently, the only effective treatment is reducing intraocular pressure (lOP) to a clinically safe range. A significant portion of individuals with glaucoma will require surgical intervention to stop progressive optic nerve damage. Current surgical options for refractory glaucoma include trabeculectomy and the use of glaucoma drainage implants. Although antimetabolites have improved success rates for trabeculectomy, their use is associated with unpredictable control of flow, hypotony, wound leaks, capsular fibrosis and infection. Glaucoma tube implants have been gaining popularity, but all current commercially available devices are plagued with a fibrotic response that ultimately limits the outflow facility of these devices and prevents lower lOP. In addition, the fibrous capsule increases the risk of motility disturbances and ptosis and ultimately limits the filtration life of these glaucoma implants. Attempts to modify the fibrotic response to conventional implants have largely been unsuccessful. There have been recent attempts to develop newer generation glaucoma implants using various biocompatible membranes with limited success. We propose a unique implant design consisting of a biocompatible membrane that demonstrates favorable flow and tissue characteristics in an animal model. We propose to integrate an existing implant with the membrane to improve performance. Once constructed, the device will be tested in a rabbit model system. At the time of explant, outflow resistance and histological analysis will be performed to evaluate the function and tissue response of the implant. With improved long-term performance, use of surgical devices would likely increase significantly. Development of a safe and effective glaucoma drainage device will greatly improve our ability to reduce blindness from this common disorder.

Agency
National Institute of Health (NIH)
Institute
National Eye Institute (NEI)
Type
Small Business Innovation Research Grants (SBIR) - Phase I (R43)
Project #
1R43EY015587-01
Application #
6791513
Study Section
Special Emphasis Panel (ZRG1-DBD (10))
Program Officer
Helmsen, Ralph J
Project Start
2004-09-01
Project End
2005-02-28
Budget Start
2004-09-01
Budget End
2005-02-28
Support Year
1
Fiscal Year
2004
Total Cost
$100,000
Indirect Cost
Name
New World Medical, Inc.
Department
Type
DUNS #
622768711
City
Rancho Cucamonga
State
CA
Country
United States
Zip Code
91730
Kim, James; Allingham, R Rand; Hall, Jason et al. (2014) Clinical experience with a novel glaucoma drainage implant. J Glaucoma 23:e91-7
DeCroos, Francis Char; Kondo, Yuji; Mordes, Daniel et al. (2011) In vitro fluid dynamics of the Ahmed glaucoma valve modified with expanded polytetrafluoroethylene. Curr Eye Res 36:112-7