Mitral valve regurgitation is a serious condition related to heart disease. The most common and effective surgical method for treating this disease is with the use of an annuloplasty ring, which reduces the size of a dilated mitral valve to restore normal function. Many patients do not receive this procedure, however, either because they are too sick to undergo open heart surgery, or their condition has not yet progressed to the point at which surgery is justified. To address this large untreated patient population, many efforts have been undertaken to develop technology to repair leaky mitral valves via catheter. Of these, the Millipede concept is the only device which can perform a true ring annuloplasty. This concept uses a stent-like ring that can both expand and contract under a radial force and has many small barbed struts around its perimeter. The ring is mounted on the distal end of an expandable, cone- shaped delivery tool prior to delivery. The collapsed dilator-ring assembly is advanced toward the annulus and the apex of the cone is pushed through the valve orifice. The cone is then expanded, which simultaneously expands the ring to a known diameter and forces the annulus into a circular shape with the same diameter, resulting in automatic alignment of the ring and the annulus. Once aligned, a simple forward push of the delivery tool drives the barbed struts into the tissue and secures the ring in place. The dilator tool is then contracted down and removed. In Phase I of this project we will build functional prototypes of the ring and delivery system and test their performance on the benchtop in pig hearts. In Phase II we will further develop this device and conduct testing necessary to achieve regulatory approval for surgical use.

Public Health Relevance

The goal of this project is to develop a percutaneous mitral annuloplasty ring for the treatment of dilated, leaking heart valves. This technology will allow leaky mitral valves to be treated without surgery, which will benefit a significant number of patients who have valve disease but are not candidates for surgery.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Small Business Innovation Research Grants (SBIR) - Phase I (R43)
Project #
1R43HL106826-01
Application #
8055673
Study Section
Special Emphasis Panel (ZRG1-SBTS-E (10))
Program Officer
Evans, Frank
Project Start
2011-08-01
Project End
2013-02-28
Budget Start
2011-08-01
Budget End
2013-02-28
Support Year
1
Fiscal Year
2011
Total Cost
$149,433
Indirect Cost
Name
MC3, Inc.
Department
Type
DUNS #
806687406
City
Ann Arbor
State
MI
Country
United States
Zip Code
48103