Atantares Corp. is seeking funding to develop a standardized foundation of thrombosis evaluation, driven through the principle of unification of standard laboratory and specialized hemostasis testing, inclusive of a diversity of tests such as thromboelastography (TEG), PT/APTT, multiple electrode aggregometer etc., with the potential for iterative advance and multiplexing. Clinical realization of such a platform is far from the mere addition of various tests into a single unit, but transformative, particularly in the pediatric cases where innate diversity in hemorrhagic and thrombotic status is juxtaposed diversity in disease and treatment. Flexible platforms are required. Equally important, sensor miniaturization through our MEMS/microfluidic approach significantly reduces required blood volume (test and dead-space) to perform these various assays, making it ideal for pediatric patients. With deep expertise in MEMS technology, Atantares Corp has designed and is reducing to practice miniaturized and accurate modules of a diversity of hemostasis assays that can be used in isolation, in serial, or in parallelizable fashion at a fraction of the cost and footprint of current stand-alone systems. This technology also synergizes closely with the academic mission of Dr. Kolandaivelu who has examined in detail, the patient specific underpinnings of patient-specific thrombotic events following endovascular manipulations and in an effort to better understand the blood-borne contributors to risk, developed multi-parameter methods of mapping an individual?s hemostatic state in high definition. Availability of a modular tool can interface directly into existing workflows and provider preferences, at the same time, being leveraged to cost-effectively and systematically build out the needed evidence-base for new applications despite diverse pediatric scenarios (innate variability, ECMO, CHD, arrhythmias, hemophilias, coagulopathies, NICU settings, etc.). In the scope of this SBIR program, Atantares Corp. will demonstrate the key advantages of MEMS/microfluid technology in functional global hemostasis assays through two specific aims that seek to 1) Create high accuracy MEMS sensors for functional hemostasis assessment (exemplified herein as a uTEG unit; note, TEG is exemplary of a complex module with growing clinical value); as well as 2) Global assay optimization to maximize signal:noise at minimal test volume.

Public Health Relevance

Management of clotting and bleeding diseases in the pediatric patient is fraught with difficulty. Proven diagnostic tools that capture the breadth of clotting and bleeding variability and meet the constraints of the pediatric environment do not exist. This project will demonstrate the key advantages of a modular Micro-Electro-Mechanical Systems (MEMS)-based sensing system in functional global hemostasis assays. This should benefit pediatric patients in diverse scenarios such as innate variability, coronary heart disease, arrhythmias, hemophilias, coagulopathies, neonatal intensive care settings, etc by enabling the development of a modular, robust, point-of- care pediatric global hemostasis assay instrument.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Small Business Innovation Research Grants (SBIR) - Phase I (R43)
Project #
1R43HL140686-01
Application #
9466736
Study Section
Special Emphasis Panel (ZRG1)
Program Officer
Warren, Ronald Q
Project Start
2018-02-17
Project End
2019-09-30
Budget Start
2018-02-17
Budget End
2019-09-30
Support Year
1
Fiscal Year
2018
Total Cost
Indirect Cost
Name
Atantares Corporation
Department
Type
DUNS #
079869357
City
Arlington
State
MA
Country
United States
Zip Code