Surgical procedures to modify corneal curvature for the correction of myopia, hyperopia and astigmatism are hampered by limited accuracy of results. Substantial variability of effect is seen with surgical procedures such as radial keratotomy, in which corneal deformation occurs in response to corneal incisions. If the procedures were based on measures of the biomechanical properties of the cornea, results would be improved, since such measures can be used to predict preoperatively the magnitude of the response of the cornea to surgery. The goal of this research is to precisely define the relationship of the mechanical properties of individual corneas to their response to surgery. The ultrasonic energy technique will be used to measure wave velocity within the cornea, allowing precise non-destructive measurement of corneal mechanical properties in vivo. The effects on these properties of biological variables, such as age and pathological corneal states (e.g. keratoconus) will be determined. Measured mechanical properties will be used in a computer finite element model to predict responses of individual corneas to surgery. The research team consists of an engineer with expertise in ultrasound instrumentation, a mechanical engineer with expertise in mathematical modeling and an ophthalmologist with expertise in corneal surgery and research.

Agency
National Institute of Health (NIH)
Institute
National Eye Institute (NEI)
Type
Research Project (R01)
Project #
5R01EY010335-03
Application #
2164144
Study Section
Visual Sciences A Study Section (VISA)
Project Start
1994-08-01
Project End
1998-12-31
Budget Start
1996-08-01
Budget End
1998-12-31
Support Year
3
Fiscal Year
1996
Total Cost
Indirect Cost
Name
University of Southern California
Department
Ophthalmology
Type
Schools of Medicine
DUNS #
041544081
City
Los Angeles
State
CA
Country
United States
Zip Code
90089
Taban, Mehran; Behrens, Ashley; Newcomb, Robert L et al. (2005) Incidence of acute endophthalmitis following penetrating keratoplasty: a systematic review. Arch Ophthalmol 123:605-9
Taban, Mehran; Behrens, Ashley; Newcomb, Robert L et al. (2005) Acute endophthalmitis following cataract surgery: a systematic review of the literature. Arch Ophthalmol 123:613-20
Taban, Mehran; Sarayba, Melvin A; Ignacio, Teresa S et al. (2005) Ingress of India ink into the anterior chamber through sutureless clear corneal cataract wounds. Arch Ophthalmol 123:643-8
Taban, Mehran; Rao, Bin; Reznik, Jacob et al. (2004) Dynamic morphology of sutureless cataract wounds--effect of incision angle and location. Surv Ophthalmol 49 Suppl 2:S62-72
McDonnell, Peter J; Taban, Mehran; Sarayba, Melvin et al. (2003) Dynamic morphology of clear corneal cataract incisions. Ophthalmology 110:2342-8
Bryant, M R; Kampmeier, J; Er, H et al. (1999) PRK-induced anisometropia in the rabbit as a model of myopia. Graefes Arch Clin Exp Ophthalmol 237:161-5
Bryant, M R; McDonnell, P J (1998) Optical feedback controlled scleral remodeling as a mechanism for myopic eye growth. J Theor Biol 193:613-22
Bryant, M R; McDonnell, P J (1998) A triphasic analysis of corneal swelling and hydration control. J Biomech Eng 120:370-81
Wang, H; Prendiville, P L; McDonnell, P J et al. (1996) An ultrasonic technique for the measurement of the elastic moduli of human cornea. J Biomech 29:1633-6
Bryant, M R; McDonnell, P J (1996) Constitutive laws for biomechanical modeling of refractive surgery. J Biomech Eng 118:473-81