Diffusion Tensor (DT) MRI provides unique information about the microscopic mobility of the water molecules in tissues that cannot be obtained with any other medical imaging technique. Diffusion weighted imaging (DWI) has become a powerful routine tool for detecting regions of cell edema in cerebral stroke. DT-MRI is generally used to examine the tracts of myelinated nerves for various white-matter diseases in the brain. However, conventional DT-MRI techniques are very sensitive to magnetic susceptibility artifacts, and cannot achieve very high spatial resolution. There is a substantial need for high-resolution DT-MRI techniques that work in difficult areas such as the optic nerves, brainstem, peripheral nerves, and spinal cord, as well as in the heart and some other organs. Multi-shot DT-MRI techniques could be used to increase spatial resolution and overcome susceptibility artifacts, but are very sensitive to phase errors due to microscopic motions during the large diffusion gradients. This project will complete the development and perform a detailed evaluation of a novel technique for robust high resolution multi-shot DT-MRI. The technique is novel in that it acquires both components of the diffusion prepared magnetization in conjunction with a single diffusion weighting and thereby eliminates non-uniform diffusion weighting due to residual phase in the diffusion weighted transverse magnetization. A navigator echo provides a measure of data quality and allows artifact reduction by dynamic data re-acquisition. For brevity, we refer to the technique as 2D or 3D nav-CADPaW-EPI (navigated composite acquisition of diffusion prepared and weighted magnetization using multi-shot EPI). After successful development, optimization, and testing of the pulse sequence, we will perform a detailed study of the accuracy, repeatability, and anatomic consistency of the resulting DT measurements in the brain, brain stem, optic nerve, and spinal cord. The technique can also be applied to any anatomic region where the susceptibility artifact is severe. The technique developed and tested in this project should ultimately improve the ability to detect early MS lesions in the optic nerve and spinal cord and provide finer detail for white matter tractography uniformly over the entire brain and nervous system.

Agency
National Institute of Health (NIH)
Institute
National Institute of Neurological Disorders and Stroke (NINDS)
Type
Exploratory/Developmental Grants (R21)
Project #
1R21NS052424-01
Application #
6959332
Study Section
Special Emphasis Panel (ZRG1-SBIB-J (90))
Program Officer
Utz, Ursula
Project Start
2005-09-01
Project End
2007-06-30
Budget Start
2005-09-01
Budget End
2006-06-30
Support Year
1
Fiscal Year
2005
Total Cost
$207,431
Indirect Cost
Name
University of Utah
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
009095365
City
Salt Lake City
State
UT
Country
United States
Zip Code
84112
Park, J K; Kim, S-E; Trieman, G S et al. (2011) High-resolution diffusion-weighted imaging of neck lymph nodes using 2D-single-shot interleaved multiple inner volume imaging diffusion-weighted echo-planar imaging at 3T. AJNR Am J Neuroradiol 32:1173-7
Kim, Seong-Eun; Treiman, Gerald S; Roberts, John A et al. (2011) In vivo and ex vivo measurements of the mean ADC values of lipid necrotic core and hemorrhage obtained from diffusion weighted imaging in human atherosclerotic plaques. J Magn Reson Imaging 34:1167-75
Zollinger, Lauren V; Kim, Tae Ho; Hill, Kenneth et al. (2011) Using diffusion tensor imaging and immunofluorescent assay to evaluate the pathology of multiple sclerosis. J Magn Reson Imaging 33:557-64
Kim, T H; Zollinger, L; Shi, X F et al. (2010) Quantification of diffusivities of the human cervical spinal cord using a 2D single-shot interleaved multisection inner volume diffusion-weighted echo-planar imaging technique. AJNR Am J Neuroradiol 31:682-7
Shi, Xianfeng; Kim, Seong-Eun; Jeong, Eun-Kee (2010) Single-shot T1 mapping using simultaneous acquisitions of spin- and stimulated-echo-planar imaging (2D ss-SESTEPI). Magn Reson Med 64:734-42
Kim, T H; Zollinger, L; Shi, X F et al. (2009) Diffusion tensor imaging of ex vivo cervical spinal cord specimens: the immediate and long-term effects of fixation on diffusivity. Anat Rec (Hoboken) 292:234-41
Shi, Xianfeng; Kholmovski, Eugene G; Kim, Seong-Eun et al. (2009) Improvement of accuracy of diffusion MRI using real-time self-gated data acquisition. NMR Biomed 22:545-50
Kim, Seong-Eun; Jeong, Eun-Kee; Shi, Xian-Feng et al. (2009) Diffusion-weighted imaging of human carotid artery using 2D single-shot interleaved multislice inner volume diffusion-weighted echo planar imaging (2D ss-IMIV-DWEPI) at 3T: diffusion measurement in atherosclerotic plaque. J Magn Reson Imaging 30:1068-77
Jeong, Eun-Kee; Kim, Seong-Eun; Guo, Junyu et al. (2005) High-resolution DTI with 2D interleaved multislice reduced FOV single-shot diffusion-weighted EPI (2D ss-rFOV-DWEPI). Magn Reson Med 54:1575-9