Flow cytometers are an indispensable biomedical tool that measures the angular scattering of light from a cell/sample and/or the fluorescence the cell/sample emits, creating the basis for routine blood counts, cancer screenings, and a wide range of other diagnostics and assays. Flow cytometers employ high-quality optical systems and complex electrical or mechanical cell sorting devices to enable sensitive, reproducible detection and sorting of cells, but these same systems make the instrument expensive to fabricate and maintain.
The aim of the project is to create a low-cost, compact flow cytometer that can be widely available to clinicians and researchers. The system will also possess unique functionality unavailable by today's system. Plastic photonic circuits will be integrated with microfluidics and microacoustically actuated cell sorters on a microchip platform. This design readily allows the creation of a sorting scheme for the ordered removal of a small number of cells of interest, allowing researchers to remove the specific cells they are interested in for additional individual studies, such as the genotyping of individual cancer cells. Device design will be carried out based on combined results from optical and fluidic simulations performed for polymer-based structures. Over the course of three years, several device test and redesign cycles will be made possible by the rapid prototyping allowed by polymer replica molding and the use of off-the-shelf piezoelectric actuators, LED/diode laser sources, and Si photodetectors. Successful demonstration of the feasibility of this device will be measured by (1) the realization of a cell detection module capable of simultaneously detecting forward scatter, side scatter, and fluorescence from standard cytometry calibration polymer beads with sufficient sensitivity to yield a coefficient of variation with 11% of that measured by a commercial benchtop cytometer. (2) the development of a system prototype with capabilities sufficient for removal of a single cell from a high-throughput flow channel (i.e. up to 100,000 cells/min per channel, multiplied by the number of channels). (3) the ability to choose and remove individual cells in flow to a spatially-indexed sorting channel for further study (e.g. genotyping of single cancer cells). ? ? The development of an inexpensive, disposable chip-based flow cytometer would make the device more widely available from a financial standpoint to both clinicians and researchers alike, helping to lower net testing costs, contain biohazard materials, and provide a more rapid turnaround on results from the wide range of tests currently run on flow cytometers, such as routine clinical bloodwork, HIV and cancer progression monitoring, or research-based cell studies. In addition, the development of our proposed single-cell sorting capabilities would automate the isolation of individual cells of interest, making it an invaluable tool for facilitating biomedical breakthroughs in areas such as our understanding of cancer, where the ability to perform single-cell genotyping for studies of the evolution of cancers will be critical. ? ? ?

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Exploratory/Developmental Grants (R21)
Project #
1R21RR024453-01
Application #
7347509
Study Section
Special Emphasis Panel (ZRR1-BT-B (02))
Program Officer
Friedman, Fred K
Project Start
2008-02-01
Project End
2011-01-31
Budget Start
2008-02-01
Budget End
2009-01-31
Support Year
1
Fiscal Year
2008
Total Cost
$173,673
Indirect Cost
Name
University of California San Diego
Department
Engineering (All Types)
Type
Schools of Arts and Sciences
DUNS #
804355790
City
La Jolla
State
CA
Country
United States
Zip Code
92093
Wu, Tsung-Feng; Mei, Zhe; Lo, Yu-Hwa (2013) Label-free Optofluidic Cell Classifier Utilizing Support Vector Machines. Sens Actuators B Chem 186:327-332
Wu, Tsung-Feng; Mei, Zhe; Lo, Yu-Hwa (2012) Optofluidic device for label-free cell classification from whole blood. Lab Chip 12:3791-7
Mei, Zhe; Cho, Sung Hwan; Zhang, Arthur et al. (2012) Counting leukocytes from whole blood using a lab-on-a-chip Coulter counter. Conf Proc IEEE Eng Med Biol Soc 2012:6277-80
Cho, Sung Hwan; Chen, Chun H; Tsai, Frank S et al. (2010) Human mammalian cell sorting using a highly integrated micro-fabricated fluorescence-activated cell sorter (microFACS). Lab Chip 10:1567-73
Godin, Jessica; Cho, Sung Hwan; Lo, Yu-Hwa (2009) On-Chip Optics for Manipulating Light in Polymer Chips. Optoelectron Commun Conf 2009:
Cho, Sung Hwan; Godin, Jessica; Lo, Yu-Hwa (2009) Optofluidic Waveguides in Teflon AF-Coated PDMS Microfluidic Channels. IEEE Photonics Technol Lett 21:1057-1059
Chen, Chun H; Cho, Sung Hwan; Tsai, Frank et al. (2009) Microfluidic cell sorter with integrated piezoelectric actuator. Biomed Microdevices 11:1223-31
Cho, Sung Hwan; Godin, Jessica; Chen, Chun Hao et al. (2008) Microfluidic Photonic Integrated Circuits. Optoelectron Mater Devices 7135:71350M
Godin, Jessica; Chen, Chun-Hao; Cho, Sung Hwan et al. (2008) Microfluidics and photonics for Bio-System-on-a-Chip: a review of advancements in technology towards a microfluidic flow cytometry chip. J Biophotonics 1:355-76