A set of four separation disks equipped with spiral channel(s) was designed for our type-J HSCCC centrifuge to improve retention of the stationary phase of polar solvent systems. Four different spiral disks were tested: two had a single spiral channel with different depths and the two had four spiral channels connected in series to provide a greater spiral pitch. Performance of each disk was tested in terms of partition efficiency and/or stationary phase retention using three different two-phase solvent systems including 1-butanol/acetic acid/water (4:1:5, v/v/v)for dipeptide separation; 12.5%(w/w)polyethylene glycol(PEG)1000-12.5%(w/w)dibasic potassium phosphate for protein separation; and 4%(w/w)PEG8000-5%(w/w)dextranT500 in 10mM dibasic sodium phosphate for determination of stationary phase retention. The results show that the spiral column retains a satisfactory amount of stationary phase for all solvent systems even at a relatively high mobile phase flow rate where the spiral pitch plays a significant role. This is particularly important in retention of the PEG-dextran polymer phase system. Separation of dipeptides with the butanol solvent system was possible using a high flow rate of the mobile phase and 4-spiral-disks with their greater spiral pitch. In protein separations with the PEG-phosphate system, the single-spiral disks yielded the best separation using the upper phase in head to tail elution mode, while the 4-spiral disks show higher retention of the stationary phase. The retention of the PEG-dextran system is much improved in the 4-spiral disks which exceed 60% at a flow rate of 0.5 ml/min. Preliminary separations of a set of dipeptide samples and proteins were successfully performed using a spiral disk assembly consisting of 8 units of a single spiral disk.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Intramural Research (Z01)
Project #
1Z01HL001054-01
Application #
6690481
Study Section
(LBC)
Project Start
Project End
Budget Start
Budget End
Support Year
1
Fiscal Year
2002
Total Cost
Indirect Cost
Name
U.S. National Heart Lung and Blood Inst
Department
Type
DUNS #
City
State
Country
United States
Zip Code
Ballinger, Megan N; Newstead, Michael W; Zeng, Xianying et al. (2012) TLR signaling prevents hyperoxia-induced lung injury by protecting the alveolar epithelium from oxidant-mediated death. J Immunol 189:356-64
Ito, Yoichiro; Yu, Henry (2009) Triangular Helical Column for Centrifugal Countercurrent Chromatography. J Liq Chromatogr Relat Technol 32:560-566
Ito, Yoichiro (2005) Golden rules and pitfalls in selecting optimum conditions for high-speed counter-current chromatography. J Chromatogr A 1065:145-68
Ma, Ying; Lang, Lixin; Kiesewetter, Dale O et al. (2004) Purification of the precursor for the automated radiosynthesis of [18F]FCWAY by counter-current chromatography. J Chromatogr A 1034:149-53
Yu, Henry; Ito, Yoichiro (2004) Preparative separation of proteins using centrifugal precipitation chromatography based on solubility in ammonium sulfate solution. Prep Biochem Biotechnol 34:1-12