The goal of this project is to integrate several demonstrated technologies for restoring lower limb function after paralysis from spinal cord injury (SCI), and examine novel stimulation schemes designed to minimize fatigue of the knee extensor musculature during standing. All existing stimulation systems for standing after SCI rely on continuous activation of the knee extensors, which results in rapid fatigue that limits their functionality and clinical utility. The primary objective of this translational study is to improve the performance of neuroprostheses for standing by developing and implementing advanced stimulation paradigms that exploit the selectivity of multi- contact peripheral nerve electrodes to prolong standing duration. Strategie for exploiting the selective activation of multiple synergistic muscle fiber populations include alternating between independent groups to reduce stimulus duty cycle, interleaving stimulus pulses to reduce local stimulus frequency, and a previously unexplored paradigm in which the oscillations of sinusoidal forces generated by each population produce a constant net output that exceeds any individual contribution. There has yet to be a successful critical evaluation of any of these methods chronically in humans, which still require rigorous bench testing. Stable and selective peripheral nerve interfaces (multi-contact spiral cuff electrodes) have recently become available for chronic human implantation and will enable the clinical assessment of advanced stimulation paradigms in individuals with SCI. We will implement each paradigm in recipients of implanted standing neuroprostheses and determine their relative benefits in terms of knee extension moment, endurance, robustness and elapsed standing duration. The numerous parameters that need to be adjusted for each muscle fiber population are currently selected ad hoc in a time consuming trial-and-error process. We will perform a series of chronic animal studies to develop and test automated methods for tuning each stimulation paradigm and selecting optimal parameters to maximize performance and generalize them to other neural interface technologies. The resulting tuning and optimization methods resulting from these studies will be verified clinically with users of a variety of implanted neuroprostheses, and will ultimately be suitable for transfer to other clinical applications.

Public Health Relevance

Neuroprostheses for standing after spinal cord injury (SCI) are plagued by rapid fatigue from continuous activation of the knee extensors which limits their functionality and clinical usefulness. This project will determine the feasibility and performance of novel stimulation paradigms that exploit the ability of new multi- contact peripheral nerve electrodes to selectively activate individual portions of different muscles in order to prolong standing duration. Stimulus waveforms will initially be constructed off-line and then implemented clinically with recipients of implanted standing systems. Methods for automatically tuning stimulation for optimal performance will be determined in a parallel set of animal studies generalizable to other applications and interface technologies. The optimized stimulus waveforms will then be deployed clinically and compared to the hand-crafted controllers. The outcome will define a new approach for enhancing the intrinsic function of individuals with SCI, and extending the clinical utility of neuroprostheses in a device independent manner.

Agency
National Institute of Health (NIH)
Institute
Veterans Affairs (VA)
Type
Non-HHS Research Projects (I01)
Project #
5I01RX001039-03
Application #
8998991
Study Section
Spinal Cord Injury (RRDA)
Project Start
2013-08-01
Project End
2017-07-31
Budget Start
2015-08-01
Budget End
2016-07-31
Support Year
3
Fiscal Year
2015
Total Cost
Indirect Cost
Name
Louis Stokes Cleveland VA Medical Center
Department
Type
DUNS #
093016124
City
Cleveland
State
OH
Country
United States
Zip Code
44141
Triolo, Ronald J; Bailey, Stephanie Nogan; Foglyano, Kevin M et al. (2018) Long-Term Performance and User Satisfaction With Implanted Neuroprostheses for Upright Mobility After Paraplegia: 2- to 14-Year Follow-Up. Arch Phys Med Rehabil 99:289-298
Freeberg, M J; Stone, M A; Triolo, R J et al. (2017) The design of and chronic tissue response to a composite nerve electrode with patterned stiffness. J Neural Eng 14:036022
Christie, Breanne P; Freeberg, Max; Memberg, William D et al. (2017) ""Long-term stability of stimulating spiral nerve cuff electrodes on human peripheral nerves"". J Neuroeng Rehabil 14:70
Schiefer, Matthew A; Tyler, Dustin J; Triolo, Ronald J (2012) Probabilistic modeling of selective stimulation of the human sciatic nerve with a flat interface nerve electrode. J Comput Neurosci 33:179-90
Gustafson, Kenneth J; Grinberg, Yanina; Joseph, Sheeba et al. (2012) Human distal sciatic nerve fascicular anatomy: implications for ankle control using nerve-cuff electrodes. J Rehabil Res Dev 49:309-21
Freeberg, Max J; Schiefer, Matthew A; Triolo, Ronald J (2011) Efficient search and fit methods to find nerve stimulation parameters for multi-contact electrodes. Conf Proc IEEE Eng Med Biol Soc 2011:7238-41
Audu, Musa L; Nataraj, Raviraj; Gartman, Steven J et al. (2011) Posture shifting after spinal cord injury using functional neuromuscular stimulation--a computer simulation study. J Biomech 44:1639-45
Schiefer, Matthew A; Tyler, Dustin J; Triolo, Ronald J (2011) Probabilistic modeling of selective stimulation of the human sciatic nerve with a flat Interface Nerve Electrode. Conf Proc IEEE Eng Med Biol Soc 2011:4068-71
Fisher, Lee E; Anderson, James S; Tyler, Dustin J et al. (2011) Optimization of stimulus parameters for selective peripheral nerve stimulation with multi-contact electrodes. Conf Proc IEEE Eng Med Biol Soc 2011:3039-42