Oxidative stress is a major component of a number of cardiovascular pathologies associated with high mortality and/or morbidity. For instance unstable atherosclerotic plaque, aortic aneurysm, and myocardial infarction (MI) each have strong inflammatory aspects resulting in generation of reactive oxygen species (ROS). We hypothesize that the ability to noninvasively image and quantify ROS will have a major impact on detection and monitoring of inflammation in the context of treatment. For example, stimulating endogenous cardiac repair mechanisms with stem cell therapy holds promise to potentially reverse the damages accrued during a heart attack. However, cell therapies face the challenge of surviving the hostile microenvironment of the acute infarction, where the combination of ischemic injury and infiltrating inflammatory cells lead to high concentrations of ROS that limit engrafted cell survival and endogenous repair. Noninvasive imaging of ROS in this context could inform on the best time post-MI to engraft the cells or could be used to monitor the effect of adjuvants (e.g. antioxidants) on ameliorating the hostile infarct microenvironment to promote cell survival. Noninvasive ROS imaging has been attempted with limited success. Nuclear-based techniques suffer poor resolution, while optical probes are limited by poor tissue penetration of light. MRI offers high resolution and deep tissue penetration and can be used to assess ROS pre-clinically. Gadolinium-based probes have been developed to generate increased signal in the presence of myeloperoxidase and have been used to image ROS in animal models of MI, atherosclerosis, stroke, and multiple sclerosis. However, the gadolinium probes are limited by low sensitivity, low dynamic range, and difficulty in quantification. We recently invented a class of manganese (Mn) based probes that utilize oxidation state change (redox) to exhibit unprecedented dynamic range in detection of ROS compared to other MR probes. Preliminary data indicates that the sensitivity of these probes can be at least an order of magnitude higher than gadolinium and that absolute quantification of ROS is feasible. In this K25 application I will expand this Mn chemistry to develop and deploy an optimized, clinically translatable ROS-sensing probe for quantitative imaging of myocardial inflammation. My career objective is to independently develop and translate new chemistries and imaging probes to interrogate the molecular mechanisms that underlie human cardiovascular disease and therapeutic interventions. This research plan builds upon my preliminary findings and leverages my skills in chemistry and biophysics. However to achieve this goal I require additional skills in MR imaging, cardiac pathophysiology, molecular and cell biology, ex vivo tissue analysis, grant writing and grant management. I have addressed these gaps with bench and theoretical training provided by my mentoring team, supplemented with didactic courses offered by Harvard, MIT and MGH. I plan to direct the results of the research plan toward an R01 proposal that I will submit in year 4.

Public Health Relevance

The inflammation following a heart attack generates high concentrations of reactive oxygen species (ROS) that contribute to cell death and limit endogenous repair mechanisms. Here, we develop a probe compound to noninvasively quantify cardiac ROS by MRI. This probe will enable better detection of inflammatory disease and the ability to monitor the effectiveness of treatment.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Mentored Quantitative Research Career Development Award (K25)
Project #
5K25HL128899-04
Application #
9689500
Study Section
NHLBI Mentored Patient-Oriented Research Review Committee (MPOR)
Program Officer
Wang, Wayne C
Project Start
2016-05-01
Project End
2021-04-30
Budget Start
2019-05-01
Budget End
2020-04-30
Support Year
4
Fiscal Year
2019
Total Cost
Indirect Cost
Name
Massachusetts General Hospital
Department
Type
DUNS #
073130411
City
Boston
State
MA
Country
United States
Zip Code
02114
Gale, Eric M; Wey, Hsiao-Ying; Ramsay, Ian et al. (2018) A Manganese-based Alternative to Gadolinium: Contrast-enhanced MR Angiography, Excretion, Pharmacokinetics, and Metabolism. Radiology 286:865-872
Dai, Lixiong; Jones, Chloe M; Chan, Wesley Ting Kwok et al. (2018) Chiral DOTA chelators as an improved platform for biomedical imaging and therapy applications. Nat Commun 9:857
Gale, Eric M; Caravan, Peter (2018) Gadolinium-Free Contrast Agents for Magnetic Resonance Imaging of the Central Nervous System. ACS Chem Neurosci 9:395-397
Gale, Eric M; Jones, Chloe M; Ramsay, Ian et al. (2016) A Janus Chelator Enables Biochemically Responsive MRI Contrast with Exceptional Dynamic Range. J Am Chem Soc 138:15861-15864