The MPFC continues to be the flow cytometer of choice for a wide variety of cell biology experiments due to its many unique capabilities, such as: volume sensing, five channels for fluorescence detection, multiple laser excitation, light scatter, and axial light loss on up to three laser beams. Experiments range from cytochemistry to multicolor immunofluorescence, to electronic phenotyping of cells from whole lung digests. And all of the above can be conducted with full sorting capabilities. In addition to the 3 main lasers (2 argon-ion and a krypton-ion), either a dye laser or small HeNe laser can be inserted in front of the 10 watt argon-ion laser for further excitation wavelength diversity. Plans are currently being formulated to modify the existing optical arrangement to provide enhanced sensitivity and resolution when weakly fluorescent probes are used. The first DiDAC system will be installed and tested on the MPFC. We have begun to purchase and assemble the components necessary to add phase sensitive detection to one of the excitation beams on the MPFC. Most of the major components are on hand but we can begin adding the hardware to the MPFC. The necessary physical spaces to add the modulator is available in front of the 10 watt argon-ion laser.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR001315-14
Application #
5223206
Study Section
Project Start
Project End
Budget Start
Budget End
Support Year
14
Fiscal Year
1996
Total Cost
Indirect Cost
Frumkin, Jesse P; Patra, Biranchi N; Sevold, Anthony et al. (2016) The interplay between chromosome stability and cell cycle control explored through gene-gene interaction and computational simulation. Nucleic Acids Res 44:8073-85
Johnson, Leah M; Gao, Lu; Shields IV, C Wyatt et al. (2013) Elastomeric microparticles for acoustic mediated bioseparations. J Nanobiotechnology 11:22
Micheva-Viteva, Sofiya N; Shou, Yulin; Nowak-Lovato, Kristy L et al. (2013) c-KIT signaling is targeted by pathogenic Yersinia to suppress the host immune response. BMC Microbiol 13:249
Ai, Ye; Sanders, Claire K; Marrone, Babetta L (2013) Separation of Escherichia coli bacteria from peripheral blood mononuclear cells using standing surface acoustic waves. Anal Chem 85:9126-34
Sanders, Claire K; Mourant, Judith R (2013) Advantages of full spectrum flow cytometry. J Biomed Opt 18:037004
Cushing, Kevin W; Piyasena, Menake E; Carroll, Nick J et al. (2013) Elastomeric negative acoustic contrast particles for affinity capture assays. Anal Chem 85:2208-15
Piyasena, Menake E; Austin Suthanthiraraj, Pearlson P; Applegate Jr, Robert W et al. (2012) Multinode acoustic focusing for parallel flow cytometry. Anal Chem 84:1831-9
Austin Suthanthiraraj, Pearlson P; Piyasena, Menake E; Woods, Travis A et al. (2012) One-dimensional acoustic standing waves in rectangular channels for flow cytometry. Methods 57:259-71
Vuyisich, Momchilo; Sanders, Claire K; Graves, Steven W (2012) Binding and cell intoxication studies of anthrax lethal toxin. Mol Biol Rep 39:5897-903
Chaudhary, Anu; Ganguly, Kumkum; Cabantous, Stephanie et al. (2012) The Brucella TIR-like protein TcpB interacts with the death domain of MyD88. Biochem Biophys Res Commun 417:299-304

Showing the most recent 10 out of 240 publications