Glucose-embedded purple membranes were used as a test specimen to evaluate the reliability of phases retrieved from 400 kV spot-scan images acquired on a 1024x1024 slow-scan CCD camera made by Gatan. This specimen was chosen because it represents a broad class of low-contrast radiation-sensitive biological objects and its structure is well established. The amplitudes of computed reflections from these images were strongly damped by the modulation transfer function of the camera. Nevertheless, their phases on average were < 12-different from the reference data of Henderson up to 8.8 ? resolution, which corresponds to 0.8 of the Nyquist frequency of the camera. Similar results are also observed with a different camera made by Tietz with 100 kV electrons. These results confirm that CCD camera can be a viable recording medium that can replace photographic film for recording images of crystalline specimens such as purple membrane.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR002250-17
Application #
6568620
Study Section
Project Start
2001-12-01
Project End
2002-11-30
Budget Start
1997-10-01
Budget End
1998-09-30
Support Year
17
Fiscal Year
2002
Total Cost
$134,676
Indirect Cost
Name
Baylor College of Medicine
Department
Type
DUNS #
074615394
City
Houston
State
TX
Country
United States
Zip Code
77030
Bucero, Marta Abril; Bajaj, Chandrajit; Mourrain, Bernard (2016) On the construction of general cubature formula by flat extensions. Linear Algebra Appl 502:104-125
Ebeida, Mohamed S; Rushdi, Ahmad A; Awad, Muhammad A et al. (2016) Disk Density Tuning of a Maximal Random Packing. Comput Graph Forum 35:259-269
Wensel, Theodore G; Zhang, Zhixian; Anastassov, Ivan A et al. (2016) Structural and molecular bases of rod photoreceptor morphogenesis and disease. Prog Retin Eye Res 55:32-51
Baker, Mariah R; Fan, Guizhen; Serysheva, Irina I (2015) Single-Particle Cryo-EM of the Ryanodine Receptor Channel in an Aqueous Environment. Eur J Transl Myol 25:4803
Rushdi, Ahmad A; Mitchell, Scott A; Bajaj, Chandrajit L et al. (2015) Robust All-quad Meshing of Domains with Connected Regions. Procedia Eng 124:96-108
Edwards, John; Daniel, Eric; Pascucci, Valerio et al. (2015) Approximating the Generalized Voronoi Diagram of Closely Spaced Objects. Comput Graph Forum 34:299-309
Wensel, Theodore G; Gilliam, Jared C (2015) Three-dimensional architecture of murine rod cilium revealed by cryo-EM. Methods Mol Biol 1271:267-92
Jeter, Cameron B; Patel, Saumil S; Morris, Jeffrey S et al. (2015) Oculomotor executive function abnormalities with increased tic severity in Tourette syndrome. J Child Psychol Psychiatry 56:193-202
Zhang, Qin; Cha, Deukhyun; Bajaj, Chandrajit (2015) Quality Partitioned Meshing of Multi-Material Objects. Procedia Eng 124:187-199
Baker, Mariah R; Fan, Guizhen; Serysheva, Irina I (2015) Single-particle cryo-EM of the ryanodine receptor channel in an aqueous environment. Eur J Transl Myol 25:35-48

Showing the most recent 10 out of 213 publications