Osteoarthritis (OA) is one of the most common disorders of humans. Osteoarthritis is a major cause of morbidity in the population over 50 and affects more than 40 million Americans. It also imposes considerable expense on the health care system. Although evidence implicates cartilage degeneration as the primary cause for OA, no cure exists as yet. Current treatments relieve symptoms but do not inhibit disease progression. Therefore, the development of new treatments is of utmost importance. Ideally, methods should target the early stages of the disease. However, the development of promising new therapies is hindered by the lack of noninvasive methods to detect early stages of cartilage degeneration. In order to address this, one needs to understand the structural and biochemical changes that occur during degeneration and to correlate these properties to measurable parameters obtained by a noninvasive method. The applicants proposed to exploit MR properties of sodium to monitor structural and biochemical changes in cartilage in order to determine the extent of the cartilage degeneration. They proposed to measure MR properties of sodium by imaging and by spectroscopy. The measurements will be made on normal bovine cartilage, on bovine cartilage (in which proteoglycans are removed selectively to mimic the structural and biochemical changes that occur in OA), and on human cartilage plugs with different stages of OA. The results obtained from the enzymatically degraded studies will be correlated to the osteoarthritic human specimens which have been histologically graded to assess the extent of degeneration. The measured MR properties rely not only on tissue sodium content and thereby contrast, but are also dependent on structural and biochemical changes. Therefore, this proposed research will aid in the early diagnosis of OA as well as aid in the development of drugs and treatment therapies.

Agency
National Institute of Health (NIH)
Institute
National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS)
Type
Research Project (R01)
Project #
5R01AR045242-02
Application #
6016894
Study Section
Diagnostic Imaging Study Section (DMG)
Program Officer
Panagis, James S
Project Start
1998-06-01
Project End
2001-05-31
Budget Start
1999-06-01
Budget End
2000-05-31
Support Year
2
Fiscal Year
1999
Total Cost
Indirect Cost
Name
University of Pennsylvania
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
042250712
City
Philadelphia
State
PA
Country
United States
Zip Code
19104
Dodge, George R; Bowen, J Richard; Jeong, Changhoon (2010) Vertebral growth modulation by electrical current in an animal model: potential treatment for scoliosis. J Pediatr Orthop 30:365-70
Witschey 2nd, Walter R T; Borthakur, Arijitt; Elliott, Mark A et al. (2007) Artifacts in T1 rho-weighted imaging: compensation for B(1) and B(0) field imperfections. J Magn Reson 186:75-85
Kneeland, J Bruce; Reddy, Ravinder (2007) Frontiers in musculoskeletal MRI: articular cartilage. J Magn Reson Imaging 25:339-44
Novotny, John E; Turka, Christina M; Jeong, Changhoon et al. (2006) Biomechanical and magnetic resonance characteristics of a cartilage-like equivalent generated in a suspension culture. Tissue Eng 12:2755-64
Borthakur, Arijitt; Mellon, Eric; Niyogi, Sampreet et al. (2006) Sodium and T1rho MRI for molecular and diagnostic imaging of articular cartilage. NMR Biomed 19:781-821
Regatte, Ravinder R; Akella, Sarma V S; Reddy, Ravinder (2005) Depth-dependent proton magnetization transfer in articular cartilage. J Magn Reson Imaging 22:318-23
Wheaton, Andrew J; Borthakur, Arijitt; Shapiro, Erik M et al. (2004) Proteoglycan loss in human knee cartilage: quantitation with sodium MR imaging--feasibility study. Radiology 231:900-5
Gougoutas, Alexander J; Wheaton, Andrew J; Borthakur, Arijitt et al. (2004) Cartilage volume quantification via Live Wire segmentation. Acad Radiol 11:1389-95
Akella, Sarma V S; Regatte, Ravinder R; Wheaton, Andrew J et al. (2004) Reduction of residual dipolar interaction in cartilage by spin-lock technique. Magn Reson Med 52:1103-9
Borthakur, Arijitt; Charagundla, Sridhar R; Wheaton, Andrew et al. (2004) T1rho-weighted MRI using a surface coil to transmit spin-lock pulses. J Magn Reson 167:306-16

Showing the most recent 10 out of 30 publications