The joint most often implicated in lower extremity osteoarthritis (OA) is the knee, where major symptoms include pain and stiffness. Skeletal tissues are regulated by their mechanical environment and receptors within bone and soft tissue that respond to mechanical stimulation are believed to play a major role in joint pain. One potential pathway for the onset and progression of OA is due to abnormal joint kinematics, resulting in elevated joint stress and cartilage damage. Treatments that alter mechanical stresses and metabolic activity in bone may be an effective strategy to alleviate pain in these patients. However, clinicians are unable to diagnose or treat these `pathomechanics' as they lack the tools to assess weight-bearing knee function and tissue stress. The overarching goal of this research is to develop novel weight-bearing computed tomography (CT) imaging to support a quantitative measure of knee joint health that measures both morphology and mechanics of the joint. As a first step towards this goal, we will research and optimize a new, very high resolution (210 m isotropic), C-arm CT-based imaging test that will measure cartilage deformation as a function of time with the subject standing in a fully weight-bearing position. We hypothesize that a mechanical model of the deformation-load curve will provide a sensitive and early imaging biomarker of OA status due to differences in cartilage material properties and their response to mechanical loading. We will optimize the acquisition of the deformation-time curve in ex vivo cadaver knees, and conduct a 40-subject preliminary study to demonstrate the potential sensitivity of the new imaging biomarker to distinguish between non-OA and different stages of OA progression. We believe that our new joint health test will enable testing of patient-specific treatment strategies that may slow or reverse the progression of knee OA.

Public Health Relevance

Osteoarthritis (OA) is the leading cause of functional decline and disability in aging populations and affects about 49.3 million adults in the US at an annual cost of $186 billion. The joint that most often is diagnosed is the knee, where major symptoms include pain and stiffness. We are developing a new, non-invasive, quantitative, 3-dimensional image-based test that will evaluate the health of cartilage in the knee joint while a subject is standing in a weight-bearing position.

Agency
National Institute of Health (NIH)
Institute
National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS)
Type
Research Project (R01)
Project #
5R01AR065248-03
Application #
9241879
Study Section
Biomedical Imaging Technology B Study Section (BMIT-B)
Program Officer
Lester, Gayle E
Project Start
2015-04-01
Project End
2019-02-28
Budget Start
2017-03-01
Budget End
2018-02-28
Support Year
3
Fiscal Year
2017
Total Cost
$432,423
Indirect Cost
$148,678
Name
Stanford University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
009214214
City
Stanford
State
CA
Country
United States
Zip Code
94304
Maier, Jennifer; Black, Marianne; Bonaretti, Serena et al. (2017) Comparison of Different Approaches for Measuring Tibial Cartilage Thickness. J Integr Bioinform 14:
Berger, M; Xia, Y; Aichinger, W et al. (2017) Motion compensation for cone-beam CT using Fourier consistency conditions. Phys Med Biol 62:7181-7215
Herbst, Magdalena; Schebesch, Frank; Berger, Martin et al. (2015) Dynamic detector offsets for field of view extension in C-arm computed tomography with application to weight-bearing imaging. Med Phys 42:2718-29
Choi, Jang-Hwan; Constantin, Dragos; Ganguly, Arundhuti et al. (2015) Practical dose point-based methods to characterize dose distribution in a stationary elliptical body phantom for a cone-beam C-arm CT system. Med Phys 42:4920-32
Choi, Jang-Hwan; Maier, Andreas; Keil, Andreas et al. (2014) Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. II. Experiment. Med Phys 41:061902
Maier, Andreas; Hofmann, Hannes G; Berger, Martin et al. (2013) CONRAD--a software framework for cone-beam imaging in radiology. Med Phys 40:111914
Choi, Jang-Hwan; Fahrig, Rebecca; Keil, Andreas et al. (2013) Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. Part I. Numerical model-based optimization. Med Phys 40:091905