Sealed sources of americium-241 emit primarily 60 keV photons which because of multiple Compton scattering produce dose distributions in water that are comparable to those from Ra-226 or Cs-137. However, americium gamma rays can be shielded by thin layers of high atomic number materials since the half value layer thickness is only 1/8th of a mm of lead for americium gamma rays as compared to a value of 12 mm for Ra-226 gamma rays. This allows effective in-vivo shielding of critical organs, for example, the bladder can be partially shielded by hypaque solution, and the rectum and sigmoid colon by barium sulfate. In addition, the exposure to medical personnel involved in intracavitary application and patient care can be reduced substantially by the use of relatively thin lead aprons and light weight, portable shields. This project seeks to continue an on-going investigation into the feasibility and development of americium sources. Dosimetry measurements around a prototype gynecological plaque applicator confirm that the dose distributions in water very similar to those produced by radium or cesium applicators can be obtained, and that highly effective shielding can be achieved by small amounts of high atomic number materials. In this project, we propose to design and fabricate a clinical gynecological tandem and plaque applicator, to perform dosimetry measurements on this applicator, to develop methods for computerized treatment planning for applications with and without shields, and to develop and test a probe for in-vivo dosimetry. Following these physics studies, we propose to introduce a first-generation americium applicator into clinical practice for treatment of gynecological malignancies, initially carrying out Phase I-II trials in patients with recurrent carcinoma of the cervix, late stage carcinoma of the cervix, post surgical carcinoma of the endometrium, etc. Based on the dose distributions and clinical experience with the first-generation applicator, a second-generation americium applicator will be designed and fabricated to carry out Phase II-III clinical studies on early and intermediate stage carcinoma of the cervix and endometrium.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
1R01CA039044-01
Application #
3177714
Study Section
Radiation Study Section (RAD)
Project Start
1985-01-01
Project End
1987-12-31
Budget Start
1985-01-01
Budget End
1985-12-31
Support Year
1
Fiscal Year
1985
Total Cost
Indirect Cost
Name
Yale University
Department
Type
Schools of Medicine
DUNS #
082359691
City
New Haven
State
CT
Country
United States
Zip Code
Meigooni, A S; Nath, R (1992) A comparison of radial dose functions for 103Pd, 125I, 145Sm, 241Am, 169Yb, 192Ir, and 137Cs brachytherapy sources. Int J Radiat Oncol Biol Phys 22:1125-30
Nath, R; Rockwell, S; King, C R et al. (1992) Development of a shielded 241Am applicator for continuous low dose rate irradiation of rat rectum. Int J Radiat Oncol Biol Phys 23:175-81
Meigooni, A S; Nath, R (1992) Tissue inhomogeneity correction for brachytherapy sources in a heterogeneous phantom with cylindrical symmetry. Med Phys 19:401-7
Muench, P J; Nath, R (1992) Dose distributions produced by shielded applicators using 241Am for intracavitary irradiation of tumors in the vagina. Med Phys 19:1299-306
Morton, J; Nath, R; Meigooni, A S et al. (1991) A simple technique for irradiation of recto-anal cancers with electrons using an internal anal shield. Int J Radiat Oncol Biol Phys 21:1337-41
Williamson, J F; Nath, R (1991) Clinical implementation of AAPM Task Group 32 recommendations on brachytherapy source strength specification. Med Phys 18:439-48
Nath, R; Urdaneta, N; Bolanis, N et al. (1991) A dosimetric analysis of Morris, Fletcher, and Henschke systems for treatment of uterine cervix carcinoma. Int J Radiat Oncol Biol Phys 21:995-1003
Muench, P J; Meigooni, A S; Nath, R et al. (1991) Photon energy dependence of the sensitivity of radiochromic film and comparison with silver halide film and LiF TLDs used for brachytherapy dosimetry. Med Phys 18:769-75
Nath, R; Park, C H; King, C R et al. (1990) A dose computation model for 241Am vaginal applicators including the source-to-source shielding effects. Med Phys 17:833-42
Nath, R; Bongiorni, P; Rossi, P I et al. (1990) Enhanced IUdR radiosensitization by 241Am photons relative to 226Ra and 125I photons at 0.72 Gy/hr. Int J Radiat Oncol Biol Phys 18:1377-85

Showing the most recent 10 out of 17 publications