The use of ultrasound in diagnostic medicine has grown at a phenomenal rate in the last few years, and ultrasonic scanners are now readily available to physicians and health care professionals. Although there have been no clinically established health risks associated with diagnostic ultrasound, there has been some scientific evidence that even microsecond length pulses of high intensity ultrasound can produce cavitation in liquids and in biological systems (e.g. Drosophila larvae that have air-filled tracheae). Since microsecond-length pulses can only produce bubbles on the scale of single biological cells, it is necessary in assessing the likelihood of cavitation from diagnostic ultrasound to develop methods for monitoring this localized cavitation. Two complementary methods are proposed. In one, the aqueous medium used in these in vitro tests is seeded with superheated drops which will vaporize if cavitation occurs in or near them. These drop vaporizations [which are also employed in neutron detection] serve to amplify the localized cavitation events so that they can be measured with common acoustic techniques. The second technique not only measures the presence of cavitation but also the strength of a cavitation event by monitoring photons produced from either sonoluminescence or chemiluminescence (if luminol is disolved in the sample). By employing these techniques we will be able to delimit the conditions of pressure amplitude, frequency, pulse duration, and pulse repetition frequency in which cavitation can occur if gas nuclei of appropriate size and concentration are present. If some of these conditions overlap with the operating conditions of commercial diagnostic equipment, then we will determine if cavitation does indeed occur in vitro using this equipment as an acoustic source. Finally, if cavitation is still observed, we will make suggestions for some extensions of the present work to in vivo situations.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
5R01CA039374-02
Application #
3178259
Study Section
Diagnostic Radiology Study Section (RNM)
Project Start
1985-09-01
Project End
1988-08-31
Budget Start
1986-09-01
Budget End
1987-08-31
Support Year
2
Fiscal Year
1986
Total Cost
Indirect Cost
Name
Yale University
Department
Type
Schools of Arts and Sciences
DUNS #
082359691
City
New Haven
State
CT
Country
United States
Zip Code
06520
Deng, C X; Xu, Q; Apfel, R E et al. (1996) Inertial cavitation produced by pulsed ultrasound in controlled host media. J Acoust Soc Am 100:1199-208
Holland, C K; Deng, C X; Apfel, R E et al. (1996) Direct evidence of cavitation in vivo from diagnostic ultrasound. Ultrasound Med Biol 22:917-25
al-Karmi, A M; Dinno, M A; Stoltz, D A et al. (1994) Calcium and the effects of ultrasound on frog skin. Ultrasound Med Biol 20:73-81
Adinno, M A; al-Karmi, A M; Stoltz, D A et al. (1993) Effect of free radical scavengers on changes in ion conductance during exposure to therapeutic ultrasound. Membr Biochem 10:237-47
Crum, L A; Roy, R A; Dinno, M A et al. (1992) Acoustic cavitation produced by microsecond pulses of ultrasound: a discussion of some selected results. J Acoust Soc Am 91:1113-9
Apfel, R E; Holland, C K (1991) Gauging the likelihood of cavitation from short-pulse, low-duty cycle diagnostic ultrasound. Ultrasound Med Biol 17:179-85
Roy, R A; Madanshetty, S I; Apfel, R E (1990) An acoustic backscattering technique for the detection of transient cavitation produced by microsecond pulses of ultrasound. J Acoust Soc Am 87:2451-8
Holland, C K; Apfel, R E (1990) Thresholds for transient cavitation produced by pulsed ultrasound in a controlled nuclei environment. J Acoust Soc Am 88:2059-69