Increasing utilization of limb sparing procedures for malignant or aggressive benign bone and soft tissue tumors frequently results in large skeletal defects in bone. The most common reconstructions involving the lower extremity include the use of osteoarticular allograft about the knee and a combination of allograft with metallic implant for proximal femur replacement. Several problems are associated with these procedures making their clinical outcome unpredictable. The underlying hypothesis of this study is that some of these problems are surgical and biomechanical in nature and can be resolved by better size matching of the graft to the host, improved implant design, and the use of an effective graft/prosthesis fixation method. The main goal of this extension project is to improve both the clinical and functional results of patients undergoing reconstruction of large bony defects around the knee and proximal femur using osteoarticular allograft and allograft/prosthetic composites. To accomplish this goal, we propose: 1) to develop an allograft size screening and shape matching program for selecting ideal allografts to fit the host bone defects, allowing near normal joint kinematics and contact pressure distribution; 2) to design and test a long-stem femoral prosthesis system to be used specifically with an allograft for proximal femur replacement; and 3) to follow up the clinical, radiographic, and functional results of patients with massive allograft transplantation. Osteoarticular bone dimension and curvature of a large population and bone bank stock will be measured using both radiographs and spatially reconstructed CT scan to form a macro-size screening scheme for allograft selection. 3-D joint kinematic analysis and joint surface contact pressure distribution will be utilized to formulate an additional microsize matching scheme. These analysis results will be used to establish a practical graft size matching index for clinical application. Using theoretical modeling and experimental testing, the effect of surgical placement of osteoarticular allograft on joint motion and pressure distribution will also be studied. An improved allograft and hip endoprosthesis fixation method for the proximal femur replacement will be tested using in vitro and in vivo canine models. The data obtained from the canine model will be used to design the human implant and validated by applying the implant and the optimal fixation technique to cadaveric femora. Radiographic analysis following the new evaluation criteria recommended by the American Musculoskeletal Tumor Society will be performed. Both objective and subjective functional assessments will be adopted for patient follow-up. The results of these studies are expected to improve the clinical outcome of massive allograft transplantation procedures in orthopedic surgery.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
5R01CA040583-10
Application #
2090263
Study Section
Orthopedics and Musculoskeletal Study Section (ORTH)
Project Start
1986-08-01
Project End
1996-04-30
Budget Start
1995-05-01
Budget End
1996-04-30
Support Year
10
Fiscal Year
1995
Total Cost
Indirect Cost
Name
Johns Hopkins University
Department
Orthopedics
Type
Schools of Medicine
DUNS #
045911138
City
Baltimore
State
MD
Country
United States
Zip Code
21218
Elias, J J; DesJardins, J D; Faust, A F et al. (1999) Size and position of a single condyle allograft influence knee kinematics. J Orthop Res 17:540-5
MacWilliams, B A; Wilson, D R; DesJardins, J D et al. (1999) Hamstrings cocontraction reduces internal rotation, anterior translation, and anterior cruciate ligament load in weight-bearing flexion. J Orthop Res 17:817-22
Li, G; Kawamura, K; Barrance, P et al. (1998) Prediction of muscle recruitment and its effect on joint reaction forces during knee exercises. Ann Biomed Eng 26:725-33
Damron, T A; Rock, M G; O'Connor, M I et al. (1998) Functional laboratory assessment after oncologic shoulder joint resections. Clin Orthop Relat Res :124-34
MacWilliams, B A; DesJardins, J D; Wilson, D R et al. (1998) A repeatable alignment method and local coordinate description for knee joint testing and kinematic measurement. J Biomech 31:947-50
Li, G; Sakamoto, M; Chao, E Y (1997) A comparison of different methods in predicting static pressure distribution in articulating joints. J Biomech 30:635-8
Damron, T A; Rock, M G; O'Connor, M I et al. (1997) Distal upper extremity function following proximal humeral resection and reconstruction for tumors: contralateral comparison. Ann Surg Oncol 4:237-46
Sakamoto, M; Li, G; Hara, T et al. (1996) A new method for theoretical analysis of static indentation test. J Biomech 29:679-85
Markel, M D; Gottsauner-Wolf, F; Rock, M G et al. (1993) Mechanical characteristics of proximal femoral reconstruction after 50% resection. J Orthop Res 11:339-49
Frassica, F J; Gorski, J P; Pritchard, D J et al. (1993) A comparative analysis of subchondral replacement with polymethylmethacrylate or autogenous bone grafts in dogs. Clin Orthop Relat Res :378-90

Showing the most recent 10 out of 18 publications