This proposal is directed toward improving tomographic imaging in diagnostic radiology and nuclear medicine. It is predicated on the claim that significant advances will be achieved in the fidelity of the images that are reconstructed from the raw detector measurements of the tomographic scanner by changing the basic elements (called """"""""basis functions"""""""") with which the image is built in the computer. The conventional basic elements for computerized tomographic imaging are the voxel basis functions, and the sinusoidal basis functions of Fourier analysis. Two classes of promising new basis functions have been developed: functions that are localized in space (as are the voxel basis functions), and functions that are not localized (similar in many respects to sinusoids). The new classes of basis functions are well-suited to constructing faithful digital image representations of the biological structures that have influenced the raw tomographic scanner data. The new localized basis functions have a number of very desirable properties not shared by voxels: they are rotationally symmetric, their Fourier transforms are effectively localized, and they have continuous derivatives of any desired order. The new non-localized basis functions are designed to perform a spatially-variant filtering operation that is required by a non-iterative method of 3D image reconstruction developed by the Principal Investigator.
The specific aims are to develop mathematical theory, efficient computer algorithms, application-specific implementations and evaluation criteria for (1) methods of iterative reconstruction from projections, (2) methods of estimating the fundamental limits on the performance of the reconstruction process, and (3) methods of non-iterative 3D reconstruction from projections. For specified imaging tasks, the level of statistical significance will be found for rejection of the null hypothesis that two methods perform a task equally well, in favor of the alternative hypothesis that one method performs the task better. The basis functions of the image representation are the essential core of all methods for computerized image reconstruction, irrespective of the medical imaging modality (e.g., CT, PET, SPECT, MRI). The development of new computer algorithms and their associated image representations will enable the full potential of scanners for functional imaging in emission tomography (PET and SPECT) to be realized by extracting as much information as possible from fully-3D low-statistics projection data.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
5R01CA054356-08
Application #
2700454
Study Section
Special Emphasis Panel (ZRG7-SSS-X (25))
Program Officer
Menkens, Anne E
Project Start
1991-04-01
Project End
2000-04-30
Budget Start
1998-05-01
Budget End
2000-04-30
Support Year
8
Fiscal Year
1998
Total Cost
Indirect Cost
Name
University of Pennsylvania
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
042250712
City
Philadelphia
State
PA
Country
United States
Zip Code
19104
Obi, T; Matej, S; Lewitt, R M et al. (2000) 2.5-D simultaneous multislice reconstruction by series expansion methods from Fourier-rebinned PET data. IEEE Trans Med Imaging 19:474-84
Matej, S; Karp, J S; Lewitt, R M et al. (1998) Performance of the Fourier rebinning algorithm for PET with large acceptance angles. Phys Med Biol 43:787-95
Marabini, R; Herman, G T; Carazo, J M (1998) 3D reconstruction in electron microscopy using ART with smooth spherically symmetric volume elements (blobs). Ultramicroscopy 72:53-65
Karp, J S; Freifelder, R; Geagan, M J et al. (1997) Three-dimensional imaging characteristics of the HEAD PENN-PET scanner. J Nucl Med 38:636-43
Lewittt, R M; Muehllehner, G; Karpt, J S (1994) Three-dimensional image reconstruction for PET by multi-slice rebinning and axial image filtering. Phys Med Biol 39:321-39
Matej, S; Herman, G T; Narayan, T K et al. (1994) Evaluation of task-oriented performance of several fully 3D PET reconstruction algorithms. Phys Med Biol 39:355-67
Furuie, S S; Herman, G T; Narayan, T K et al. (1994) A methodology for testing for statistically significant differences between fully 3D PET reconstruction algorithms. Phys Med Biol 39:341-54
Lewitt, R M (1992) Alternatives to voxels for image representation in iterative reconstruction algorithms. Phys Med Biol 37:705-16
Herman, G T; Roberts, D; Axel, L (1992) Fully three-dimensional reconstruction from data collected on concentric cubes in Fourier space: implementation and a sample application to MRI. Phys Med Biol 37:673-87