The superheated drop detector (SDD) consists of a collection of superheated drops suspended in a gel. Its operation is based on the same principle as that of the bubble chamber; namely, the initiation of vapor bubbles by energetic ions in superheated liquids. Since the drops are kept in a """"""""perfectly smooth"""""""" container, i.e. another liquid, the sample can be maintained in a superheated state for a long period of time. It has already been shown that direct readability, simplicity of preparation and low cost make it potentially useful in the measurement of neutron dose equivalent for patients underling high energy x-ray or electron radiotherapy. New photon-sensitive SDDs have recently become available that open up new possibilities for dosimetry applications. A major objective of this project is to generalize the SDD technology to detect radiations above a selected linear energy transfer (LET) by varying the degree of superheat. In the first phase of this project photon-sensitive SDDs will be developed, tested and characterized for 2-and 3-dimensional dosimetry of brachytherapy sources using optical tomography and MRI to quantitatively characterize the bubble distribution produced in the detector. Using this new technology, anisotropy of dose distributions around photon-emitting brachytherapy sources will be determined, thereby permitting better dose estimates to patients and therefore improved source design and patient treatment. The source-to-source shielding effects in multisource configurations simulating clinical implants will be investigated using SDDs. Also, the 3-dimensional SDDs will be used to investigate the effects of customized shields in brachytherapy applicators. In the next phase of this project, the generalized SDD systems will be developed to measure radiations with LET above a specified threshold value, which clinical applications in radiation therapy modalities using high energy proton beam, neutron beams, boron-neutron capture therapy and neutron brachytherapy; with special attention to the dosimetry of high energy proton beams for radiotherapy. One of the secondary specific aims of this project is to update the information on photoneutron yields from currently available radiotherapy accelerators.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
3R01CA064547-03S1
Application #
2875639
Study Section
Radiation Study Section (RAD)
Program Officer
Mahoney, Francis J
Project Start
1995-05-01
Project End
1999-04-30
Budget Start
1997-05-01
Budget End
1999-04-30
Support Year
3
Fiscal Year
1998
Total Cost
Indirect Cost
Name
Yale University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
082359691
City
New Haven
State
CT
Country
United States
Zip Code
06520
d'Errico, F; Curzio, G; Ciolini, R et al. (2004) A neutron dosemeter for nuclear criticality accidents. Radiat Prot Dosimetry 110:487-90
Lamba, Michael; Holland, Scott K; Schmithorst, Vincent et al. (2003) Fast high-resolution 3D segmented echo planar imaging for dose mapping using a superheated emulsion chamber. Magn Reson Med 49:675-81
d'Errico, F; Agosteo, S; Sannikov, A V et al. (2002) High-energy neutron dosimetry with superheated drop detectors. Radiat Prot Dosimetry 100:529-32
d'Errico, F; Alberts, W G; Curzio, G et al. (2001) A directional dose equivalent monitor for neutrons. Radiat Prot Dosimetry 93:315-24
d'Errico, F; Apfel, R E; Curzio, G et al. (2001) Electronic neutron personal dosimetry with superheated drop detectors. Radiat Prot Dosimetry 96:261-4
d'Errico, F; Luszik-Bhadra, M; Nath, R et al. (2001) Depth dose-equivalent and effective energies of photoneutrons generated by 6-18 MV X-ray beams for radiotherapy. Health Phys 80:4-11
d'Errico, F; Nath, R; Nolte, R (2000) A model for photon detection and dosimetry with superheated emulsions. Med Phys 27:401-9
d'Errico, F; Nath, R; Tana, L et al. (1998) In-phantom dosimetry and spectrometry of photoneutrons from an 18 MV linear accelerator. Med Phys 25:1717-24
D'Errico, F; Nath, R; Silvano, G et al. (1998) In vivo neutron dosimetry during high-energy Bremsstrahlung radiotherapy. Int J Radiat Oncol Biol Phys 41:1185-92
d'Errico, F; Nath, R; Lamba, M et al. (1998) A position-sensitive superheated emulsion chamber for three-dimensional photon dosimetry. Phys Med Biol 43:1147-58